WQ Series Submersible Centrifugal Sewage Pump Details:
Minimum Order Quantity: | 1 set | Unit: | set | Loading Port: | Shanghai |
Supply Ability: | 10000 set/month | Payment Terms: | TT OR LC | Package: | Wooden Case |
Product Description:
Product outline
WQ series submersible sewage pump absorbs the advantages with the same products made abroad and at home, holds a comprehensive optimized design on its hydraulic model, mechanical structure,sealing, cooling, protection, control etc. points, features a good performance in discharging solids and in the prevention of fiber wrapping, high efficiency and energy-saving, strong reliability and, equipped with a specially developed electric control cabinet, not only the auto-control can be realized but also the motor can be made sure to work safely and reliably.Available with various types of installation to simplify the pump station and save the investment.
WQ series submersible sewage pump is mainly used for the municipal works, buildings, industrial sewage and sewage treatment to discharge the sewage, waste water and rainwater containing solids and long fibers.
Characteristic and advantage
1. Most of the impellers with the pump of an aperture below 400 come as a bi-runner impeller and few of them is a multi-blade centrifugal impeller. While most of the impellers with the pump of an aperture 400 and above come as a mixed flow impeller and few of them is a bi-runner impeller. The spacious pump casing runner lets the solids easily passing and the fibers uneasily wrapping so that it is most suitable for discharging sewage and dirt.
2. Two independent single end-face mechanical seals are in-series mounted, with the installation mode as the internal installation mode, and, compared with the external installation mode, the medium is more uneasy to leak and also its sealing friction pair are easier lubricated by the oil in the oil chamber. A special spiral slot or a small seam is used to resist the solid
grains to be deposited on the mechanical seal by the pump to make sure of its stable work. The unique mechanical seal layout mode and bearing combination makes the suspension arm of the shaft short, a heavy rigidity and a small jump, more benefit for reducing the leak from the mechanical seal and extending the life of it.
3. The motor of a protective grade IPX8 works in submerged mode and holds the best cooling effect. The grade F insulation makes the winding bearable to a higher temperature and, compared with common motors, more durable.
4. The perfect combination of the special electric control cabinet, the liquid level floating-ball switch and the protective components carries out the automatic monitor and alarm for
water leak and winding overheat, the protections at shortcircuit, overload, lack-of-phase and voltage-lost cut-off, the accurately auto-controls of start, stop, alternation and minimum
submerged depth of the pump, without need of special persons for looking-after, option at will is available between the selfcoupled reducing start and electronic soft start. All of these
makes sure of safe and reliable use of the pump without any worry.
5. Both motor and hydraulic parts are directly linked together, without need of turning the shaft for centering, easily disassembled and assembled to save the time, benefit for the
site maintenance, reducing the stopped time, saving the cost of repair; simple and compact structure leaves a small volume, only simple lifting equipment is needed, as a special lifting
handler is set on the pump; less land area and the pump can be placed directly in the sewage pond, without need of a special pump house, and the therefore the construction investment
can be saved by over 40.
6. Available with five installation modes for you to choose: auto-coupled, movable hard-pipe, movable soft-pipe, fixed wet type and fixed dry type installation modes.The auto-coupled installation means the connection between the pump and the water-out pipeline is made with the water outlet pipe seat of the auto-coupling, without use of the common fasteners, and, when to separate the pump from the water outlet pipe seat, just place it down along with the guide rod and then lift it, simply enough to get free from worry and trouble and save time.
The submersible sewage pump in the fixed dry type installation not only can replace the old vertical sewage pump but also does not fear of flood submersion, so there is no need of a separate flood-proof facility, benefit for lowering the cost of construction.
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- The size of the outlet flow pressure compensated variable displacement pump with outlet pressure of approximately in a certain range according to the constant power curve. When the pressure oil from the main part of the channel (a), (b), (c) into the inferior vena cava (d) variable shell, oil by the channel (E) respectively into the channel (f) and (H), when the spring force is greater than the oil (f) into the lower end of the piston ring servo hydraulic thrust area when the oil liquid (H) to the chamber (g), push the variable downward movement of the piston, the pump flow increases. As for the hydraulic servo piston end thrust force ring shaped area is greater than the spring when the servo piston moves upward, blocking channels (H), the (g) (I) through the cavity of the oil cavity pressure relief, at this time, the piston moves up, the variable head angle decreases, the pump flow rate decreases.
- Q: Fire pump and shower pump flow head selection, high resolution.
- Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
- Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
- Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
- Q: What should I pay attention to when buying a pump?
- There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
- Q: What's the pump? Where can I use it?
- A pump is a machine that transports liquids or pumps liquids. Pumps are ubiquitous in life. They can be used to transport liquids such as water, oil, acid and alkali, emulsions, suspensions and liquid metals, as well as liquids, gas mixtures, and liquids containing suspended solids.
- Q: The distance from the pump button to the ground
- A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
- Q: Double floor sewage pump circuit diagram of a small problem
- Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
Send your message to us
WQ Series Submersible Centrifugal Sewage PumpS
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches