• Underwater Submersible Pumps for Wells and Tanks System 1
  • Underwater Submersible Pumps for Wells and Tanks System 2
  • Underwater Submersible Pumps for Wells and Tanks System 3
Underwater Submersible Pumps for Wells and Tanks

Underwater Submersible Pumps for Wells and Tanks

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Underwater Submersible Pumps for Wells and TanksBrief
It is one of the new generation sewage pump ,which designed base oninternational advanced
technology,advanced in energysaving,high efficiency,wrapped proof,non clogged,auto
installation and control,have excellent performance for medium contains particles and
fibres.


Working Condition
1. Medium temperature can not exceed 60degree normally.
2. S.G:1.0-1.3kg/dm3
3. PH:5-9


Application
Mainly apply to delivery sewage water ,waster water and rain water contains solids and
fibres:
*municipal project
*building construction
*residential area
*industrial sewage treatment
*eviroment protect
*mining


Features
1. Hydraulic design with wide flow-path non-clogged structure ,allowed fibres(3 times
length of inlet diameter),particles(30% size of inlet diameter )
2. Excellent design,high efficiency and energy saving .
3. Double mechnical seals in series,made of hard alloy corrosive proof silicon
carbide,which is durable and .wearable ,that enable pump safely operation for more
than 8000 hours continous.
4. Compact structure, small volume, easy moved and conveniently mounted , no need build
pump house, greatly reduct the cost.

Q: I am planning to make a overflow box for my 55 gallon saltwater tank and need to know whats a good pump to get the water back up???
Rio pumps are inexpensive and are very very durable. I highly reccomend them. I keep my sump level fairly low so that when i see bubbles in the display tank cause the pump is sucking a little air, i remember to add top off water. My pump sucks air about once every other week prolly for a few hrs at a time, until i get home from work and its still going strong! (I know this isnt the best way to do it, but if i dont run it low enough for it to suck air i totally forget to add top off water). I havent had to replace the pump yet. I also replaced my outdoor garden fountain pump with a rio. It sucks up leaves and junk all the time with no problems (except when the leaves cover where it sucks the water but thats not the pumps fault lol)
Q: can't get the pulleys to line up I know I have a mid 70's 400 and the water pump is later than 1969 but I can't find a pulley that works every one is about a half inch off I bought a aftermarket set of underdrive pulley's from march performance and still the same problem the water pump is a half inch off there was no long or short water pump right they are all the same lenght right??? The only difference I know of is that pre 1968 the pumps have a 8 bolt design and after they have a 11 bolt design is that right???
did you happen to loose the aluminum spacer between the water pump output shaft, and the fan pulley?
Q: If the water pump does not get water to pump, will it be burnt out? If so, then can it be fixed? And if it doesnt get water to pump, what exactly happens to it?
Jennifer said it so rated her, it's called air spin and she told you the rest
Q: Flow 70 cubic meters per hour; lift 35 meters, choose what standard water pump?
If you want to install simple, you choose vertical single stage pipeline pump, he imports and exports in a straight line above, installation super simple. If the installation does not require, IS ah, GD ah, you can.
Q: i learned from wikipedia that the water pumps back to reactor where it is heated again and the cycle begins again. but then i saw this diagram
I can see why you're a little confused. There are actually 3 separate loops in most reactor designs and you can see this in the diagram. The primary heat transport loop contains the water that touches and cools the fuel and this is the water that is pumped back to the reactor where it is heated again.... It is shown in the diagram in pink. The water from the primary heat transport loop passes into a steam generator which is full of water but the water in these two systems is kept separate to ensure all radioactivity stays in the primary heat transport loop and in the containment building. Basically the pipes from the primary heat transport system pass through a large tank of water and heat the water in the tank causing it to boil. The steam is then passed out of the generator, out of containment, and into the turbine. Next it goes into a heat exchanger which is similar to the steam generator except it is used to cool the water. The cooled water then passes back into containment and into the steam generator to be boiled again. Finally, the third heat transport loop moves cold water from either a lake, ocean, or cooling tower, into the turbine building where it cools the water in the secondary heat transport loop. This water is kept completely separate from the water in the secondary heat transport loop to ensure that if the secondary loop water somehow becomes contaminated, it doesn't pass into the third loop and get into the lake, ocean, or atmosphere. I hope that clears things up :)
Q: how much would they charge me to change a water pump on my 1999 cadillac deville
They always change the water pump and timing belt together while the engine is apart. Your 1999 is probably due for both things if they have not been done. I just had mine done on a Toyota Camry. It cost a thousand dollars. Remember that these two things NEED to be changed every so often..if either the water pump, or timing belt go while you are driving..your car will die right there on the freeway...even if you are going 80 MPH.
Q: It stops and every few minutes and when it stops, it sounds like water is running.
I've had the same problem. The piping going into the well is probably broken and the pump is just pumping water back into the well because it can't build up enough pressure. If it is just momentarily stopping and nothing in the house is running, the leak is small enough to let the tank build up pressure, but it bleeds off and the pump restarts. It could also be that the pressure bladder in the tank is bad. Either way it will burn your pump out in short order if you don't see to it very soon. Papaw
Q: i have an underground water tank, my jet pump went out again, got a new one, waiting for the guy to come install it. i got an old fashioned iron hand pump, for when the electric, or the pump goes out again, i can pump out water. got pipes, fittings, foot valve. i just dont know what kind of base to make ,to bolt pump to, over the pipe that will come out of the ground. any ideas?
you can make a wooden floor cover using a treated good lumber of 1 X 6 for the floor and 2 X 6 lumber for the floor joist. assemble the 2X6 lumber for the floor joist. depending on the top area of your water tank. arrange the floor joist at 0.60 meter spacing and 1.2 meter braces. after that, use 1X6 lumber as flooring with at least 2 cm spacing between lumber. as on the base of your pump, you can reinforce it by adding 2X6 braces. use a lug bolt depending on the size of the slot at the base of your pump then bolt it on top of the 1X6 flooring. its better if we can draw it here to make it easier to understand and explain i dont know if this can help much because we havent seen the actual situation of your tank and your pump.
Q: I have a 2002 honda civic with 85k miles the dealer says the timing belt should be replaced. But with the water pump timing belt tensioner also have to be replaced???
I agree with the dealer.It may sound like he is trying to jack up the job but in fact it will save you money and grief in the long run. Getting to those parts is so labor intensive that if you have to go back in later to change the pump or tensioner pulleys it will cost you the same as it did to have the belt changed. The other thing if the pump starts leaking on a new belt you will have to have it replaced again. Whenever I do a timing belt I change everything that is in there. Then I don't have to worry about it.
Q: Why can't sprinkler system and hydrant system share water pump in fire fighting system?
Why not share mainly because the two impurities contained in the water system: fire hydrant system requirements of different impurities in the water spray system requirements loose, but more stringent requirements, therefore, the former can be welded steel pipe, the latter must use galvanized pipe, the purpose is to prevent rust plug flow indicator or end of the spray head.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords