1. Applications:

For water supply from wells or reservoirs. 

For domestic use, for civil and industrial applications. 
For garden use and irrigation.


2. Features of deep well pumps :

1>. 100% copper wire, automatic wiring

2>. Cold-rolled silicon steel sheet, with high-speed punching

3>. 304 Stainless steel welding shaft

4>. Over-current protector imported from Taiwan

5>. C&U bearing ( best bearing of China)

6>. No leakage with the high quality Mechanical seal

 

3. Operating condition

1>.Water temperature is not more than 35°c

2>.The PH value of water source is 6.5-8.0

3>.Solid content in water not more than 0.01%; diameter of the bigest particle not more then 0.2mm;

4>.Water coolant system

5> Motor ratation speed 2850rpm/min. 

6>. Protective Device grade: IP68

7>.Insulation Grade: F

8>.Minimum water flow required to flow through motor:8cm/s

9>.Maximum Start count per Hour :30 times

10>. Can be installed vertically or horizontally

11>.Flat water proof cable with separate groud wire.


4. Motor Details:

1>.Rewindable motor

 2>.Single phase: 0.37-2.2 kw    220V( ±10%)-50Hz

 3>.Three Phase: 0.37 to 7.5kw  220/380V(±10%)-50Hz;  230/400V ( ±10%)- 50Hz


5. FAQ:

1> Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2> Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3> Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.

Deep Well Submersible Water Pump With Good Performance

Deep Well Submersible Water Pump With Good Performance


Q: What are the important parameters of the pump?
Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and acceleration of gravity, is the effective energy output from the pump in unit time of liquid -- effective power pump:Pe= P gQH (W) = QH (W)In the p - density of liquid pumping (kg/m3);Gamma - pump heavy liquid delivery (N/m3);Q - pump flow (m3/s);H - pump lift (m);G - gravitational acceleration (m/s2)The shaft power P and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said.
Q: The water tank of the fish tank does not air out and only has the water outlet
The water pump is cut off, the intake pipe is drawn out, and the water in the air pipe is blown out, then the water pump is put on the surface of the water, and the air inlet pipe is inserted on the surface of the water pipe, and then the water pump is put back into the water, and the water pump is electrified. Try again several times at a time. It should be effective.
Q: Is the diaphragm pump and the drain pump one?
Generally composed of actuators and valves.Pneumatic diaphragm pump, which has four kinds of materials: plastic, aluminum alloy, cast iron, stainless steel. The electric diaphragm pump has four kinds of materials: plastic, aluminum alloy, cast iron and stainless steel. Diaphragm pump diaphragm according to different liquid media, respectively, NBR, chloroprene rubber, fluorine rubber, PTFE, poly 46 ethylene to meet the needs. Placed in a variety of special occasions, for pumping various media.
Q: Is the sewage pump the same as the mud pump?
The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
Q: Working principle and structure of external gear pump
When the meshing teeth on one side of the suction chamber are gradually separated, the volume of the suction chamber is increased, and the pressure is lowered, and the liquid in the suction pipe is sucked into the pump; the suction liquid is divided into two parts to be pushed into the discharge chamber by the gear in the alveolus. When the liquid enters the exhaust chamber, the liquid is squeezed and discharged from the exhaust chamber into the discharge pipe because the teeth of the two gears are continuously engaged. The driving gear and the driven gear keep rotating, and the pump can continuously inhale and discharge the liquid. The pump body is equipped with a safety valve, when the discharge pressure exceeds the required pressure, the delivery liquid can automatically open the safety valve, so that the high-pressure liquid returns to the suction pipe.
Q: Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
By adjusting the amount of oil entering into the hydraulic coupler, the torque of the hydraulic coupler can be controlled
Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
Q: What are the problems that should be paid attention to when using vacuum pumps?
(8) in the process of running the pump, the bearing temperature shall not exceed the ambient temperature 35C, and the maximum temperature shall not exceed 80C.(9) if the abnormal sound of the vacuum pump is found, the reason should be stopped immediately.(10) vacuum pump to stop using, first shut down valve, pressure gauge, and then stop the motor. (11) vacuum pump in the first month of work, 100 hours after the replacement of lubricating oil, oil every 500 hours after the change.(12) adjust packing gland regularly to ensure the normal condition of drip in packing room. (13) regular inspection of shaft sleeve wear, larger wear should be replaced in good time.
Q: How many concrete pump tube diameter
The pump is generally divided into 125 and 150 two, the inner diameter is 125mm and 150mm. And the two kinds of each have high and low pressure points. Low pressure type type 125 pump for the pipeline diameter is phi 133,
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.