Spectacle wear plate DN200 for Cifa concrete pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000sets per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Spectacle wear plate DN200 for Cifa concrete pump
1.Specifications:
Size | DN200,DN230 |
Material | tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany |
Lifetime | 30,000-80,000cbm |
Carbide HRA | > 86 |
Electrode HRC | > 63 |
Type | hardfaced, tungsten carbide and 7 shape tungsten carbide |
Application | mud pump, shotcrete,trailer and truck mounted concrete pump |
Manufacturer with competitive price |
Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below
Technology | Technical Standard | Service Life | Hardness |
Atmosphere sintering process | SY5064-85 | 5 times more than similar traditional product | HRC>70 |
Tensile Strength | Fracture Toughness values | Yield Strength | |
>1000Mpa | 10 Mpa1/2 | >1000Mpa | |
Substrate/Matrix Material | Bending Strength | High Temprature Resistance | Surface Roughness |
45#,40Cr, 1Cr13 steel | 1100-1300 Mpa | 700-800 centigrade degree | Ra<0.1 |
Bond Strength | Corrosion Resistance | Compactness | |
>110Mpa | >95% | Gas Hole Ratio<0.01% |
2.Packing:
1. Outside package: standard export wooden case
2. Inside package: bubble bag
3. Why choose us?
1. Manufacturers with 8 year's experiences.
2. High quality, best price, prompt delivery.
3. Standard quality control system
4. Small orders are accepted.
Experience: 1. over 8 years concrete pump wear part’s experiences.
2. 4 years gold supplier on alibaba.
3. 2 years OEM.
Quality: 1. ISO9001 certification.
2. Strictly quality control with every process.
3 . Material: electrode imported from Germany. Q235B steel body.
4. High performance.
5. Advanced manufacturing equipment and leading technical.
Type: Different types with different lifetime.
OEM, ODM is acceptable.
Service: Delivery: 7-10 days after receiving the money.
MOQ: 1 set.
Prompt attention must be paid to any requirement and inquiry.
Price: Different price with different types,
we are faithfully that our price can help you beat your competitor with the same type product.
We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.
OEM service is available, products can be produced as buyer's drawing or samples.
At the same time, we also sell following parts with good quality and competitve price:
1. Concrete pump clamp in casted and forged
2. Concrete pump rubber hose
3. Delivery pipe and elbow
4. Piston
5. Sponge ball
6. Delivery cylinder
7. Plunger cylinder
Any questions, I am Hilary here. feel free to contact me.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: What are the internal losses in centrifugal pumps? How did they come about?
- Due to the friction of the bearing, the friction in the stuffing box, and the losses caused by the rotation of the impeller (the loss of the roulette wheel);
- Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
- Pump control system is generally used for closed systems, the flow of the oil pump changes to control the motor or cylinder actuator action. The utility model has the advantages that the principle is simple, and the power of the engine can be fully utilized. The disadvantage is that the calorific value of larger, relatively poor precision.
- Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
- The purpose of the steam separator is to separate the gas from the liquidWater ring type vacuum pump, water, compressed gas is discharged through the exhaust port, if not it is soda water separator is discharged, can not be separated, for the recovery of gas discharged industry is obviously impossible.Soda separator is available, the key is to see the working conditions
- Q: What are the functions of a disposable infusion pump?
- When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
- Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
- Suction is allowed to pump the vacuum from the distance from the inlet, which is part of the field installation.The manufacturer of cavitation allowance is closely related to the design and process of pump. Estimation formula: cavitation allowance =10.33 meters - allow suction of -0.5 meters (safety).
- Q: What are the basic technical parameters of the pump?
- Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
- Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
- The air pump.The pump itself is mechanical failure.The pump outlet valve core off.Low voltage power.
- Q: What are the parts of a pump? How do you classify it?I just want to know
- Before opening the pump suction pipes and pumps must be filled with water. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet. The outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuous outflow from the discharge pipe.Mainly by the impeller, pump shell, pump shaft, bearings and packing sealing devices and other components
Send your message to us
Spectacle wear plate DN200 for Cifa concrete pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000sets per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords