Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
1. Application
This product is suitable for AC rated voltage 15KV and below frequency control system for power cables or electrical connections, the product has a strong impact resistance, voltage, pulse voltage inverter can withstand time, the cable has a good shielding performance, and effectively eliminate electromagnetic interference reduce the frequency conversion motor noise, to ensure stability of the system. Widely used in metallurgy, electric power, petrochemical and industries.
2. Type and Specification
Voltage | 3.6/6 kV、6/6 kV、6/10 kV、8.7/10kV、8.7/15kV |
Type | Z-BPYJVP12、Z-BPYJVP12-22、Z-BPYJVP2 |
Specifications(mm2) | 3 Core:25~300 |
Standard | Q/XLJ 0349 |
3. Using Features
① Rated voltage Uo/U 3.6/6kV 、6/6kV 、6/10kV、8.7/10kV、8.7/15kV.
② Long-term allowable working temperature of cable conductor is 90 ℃
③ When the short-circuit (The longest duration of no more than 5S) conductor maximum temperature does not exceed 250 ℃.
④ When the ambient temperature of cable laying should not below 0 ℃, the minimum bend radius of 12 times the cable diameter.
⑤ Cable has good shielding performance, may reduce the adverse effects of higher harmonics of the inverter output exist.
⑥ DC resistances of conductor comply with GB / T 3956.
⑦ Cable flame-retardant characteristics comply with the requirements GB / T 19666.
4. Picture of Structure
1、Conductor 2、Insulation 3、Filler 4、Tape 5、Copper wire shield 6、Copper tape shield 7、Inner sheath 8、Armor 9、Outer sheath
FAQ
Q: How’s your service?
A:1. Offer customers 24/7 service, whenever you need us, we are always here for you.
2. Immediate response. Your any inquiry will be replied within 24 hours.
3. Support small order quantity, for the first time cooperation customers, we can send you less quantity for trial order.
4. Support third party inspection company to inspect and check the quality and quantity before delivery.
- Q:i have an hp7500 and their is only two pin spots on the 9400 cable
- Huh? Do you have the right model #? The only cable on the 9400GT should be the fan cable, and it should plug into the card itself (see picture in the link)
- Q:I already have RCA cables. Just need to find a place that would sell the power cord.
- If you do get your hands on the cable- don't lose it. I wrecked my car, and when i was removing the stereo, i forgot the cable. I looked all over for the darn thing, luckily, an installer had a guy who's changer had broken, but they kept the cable for some reason.
- Q:i wanna know how much distance should be in between the power cable and the cat5 cable
- it could be ok at a few inches however i personally had experience where it had to be a few feet but only with power going to a florecent light... whenever light was turned on i lost net yet cat5 could be run right next to light itself or other power lines no problem.. fyi, no one could figure it out, even qwest dsl service people ( 3 in all) - ended up having to be 3 feet from just that certain power line
- Q:i want to run a power cable from my battery from under the hood to my trunk for a amp that i want to power. i have a 94 mercury cougar. and i have seen it done under the car and through the firewall into the cockpit, if i want to run it through the firewall which way do i put it through? can someone send me a link to a pictured instructions? or just tell me how? thanx
- if you run the power line in the cabin, run it on the opposite side of the RCA cables you are going to run from the deck to the amp. This will reduce any magnetic interference caused by current in the power line affecting the signal source.
- Q:Can I use a standard 12 volt power cable on an Elmo projector?
- Possibly on the BoxiT-200 that takes 12 to 19 volts at 3 amps, positive center. Read the printing on user manual, it gives the requirements. Most other Elmo projectors are plugged into an ac outlet.
- Q:What is the difference between the power BV line and the power YJV cable?
- Generally wear SC65 tube. If the distance is too long, elbow and more, then the choice will be larger.
- Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
- Power cable YJV22-8.7 / 15kv-3 * 300 Meaning: refers to the copper core XLPE insulated double steel tape armored PVC sheathed power cable, cable rated working voltage 8.7 / 15KV, cable for the three-core, single Conductor cross-sectional area of 300mm2. YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated working voltage 8.7 / 15 kV 3 * 300 Specifications: YJV22-8.7 / 15kv-3 * : Three conductors, single cross section of 300 square feet.
- Q:I have a usb powered cup warmer. It has a car adaptor. I would like to know if its possible to use it to charge my cellphone in the car, instead of buying a car adaptor.
- The max power you can draw from a USB port is 2.5W (500 mA at 5V)
- Q:I am planing to install a 7770 on my PC but i need a pci-e cable to power it on. So is that cable included or i should purchase one?
- hi renaldo you have two options .... either use a 6pin connector from your existing power supply,or use the molex (2) to 6pin adapter that comes with the radeon HD7770 however theres other factors to consider and these include : 1) wattage : the HD7770 requires a minimum of 450w ... but this is based on a decent well known brand of psu .... less expensive budget or generic psu,s and you should be looking at 500w or even 550w 2) +12v rails : these are the part of the psu that delivers the power to your HD7770,and each card requires a set amount of amps on the +12v rail(s) ...
- Q:Indoor dry bag type steel core power cable terminal what is the meaning
- You ask this is too professional, it is difficult to answer, to ask the air conditioning technical staff Caixing.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords