• Plastics insnlated and sheathed control cable System 1
Plastics insnlated and sheathed control cable

Plastics insnlated and sheathed control cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

As connecting wires of all kinds of electrical instruments and automatic devices to control, monitor and protect circuits of AC.

Specification :

1.Better quality & Faithful business

2.Prompt delivery & reasonable price

Plastic Insulated control Cables are used for rated voltage up to and including 450/750V

The long-term operating temperature of PVC insulation cable conductor should be lower than 70°C,and that of XLPE insulation should be lower than 90°C

The installing ambient temperature of cables shouldn’t be lower than 0°C,the Min. bending radius of installing is 6 times of the outer diameter

Unarmored control cables

Such unarmored control cables are suitable for laying indoors and in the electrical cabinets, however, the cables can’t bear larger external mechanical forces.

PVC sheath has stable property and excellent chemical corrosion protection characteristics, also with the features of non-fire propagation and non-water absorption, which greatly ensure the cables’ service life.


Control cables with steel wires armored

Steel wires armored control cables can endure certain mechanical tension, which are widely suitable for high-level difference environment, also can be installed vertically

Cables with screen have good shielding and anti-interference performances.
Control cables with screen

Generally speaking, there are two ways of copper wires braided screen and copper tape wrapped screen for control cables, however, copper wires braided screen has stable structure, the effect of screen won’t change with the cable bending or appearance factors etc, but also doesn’t have influence on cables’ flexibility, braiding density can reach over 80%, besides,copper tape wrapped screen percentage of coverage can reach up to 100%.


The specific models see the  Annex 2

Annex 2: LSZH-XLPE/ Irradiated Cross-linked Insulated Control Cables

WDZ-KYJY

WDZ-KYJ(F)Y

Copper conductor, XLPE/radiated crosslinked insulation and Polyolefin sheath flame retardant control cable with LSZH

For laying in doors and in ducts, the cable has property of flame-retardant with high requirements of safety and environment-friendly cables.

WDZ-KYJYP

WDZ-KYJY(F)P

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper wires braided shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJYP2 WDZ-KYJY(F)P2

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper tape wrapped shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJY23

WDZ-KYJ(F)Y23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and steel tape armored control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP23

WDZ-KYJ(F)YP23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper wires braided screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP 2-23

WDZ-KYJ(F)YP 2-23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper tape wrapped screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

Q: I bought this graphics card tonight, and went to install it on my new Dell PC and while the card itself is powered by a 6-pin, I don't have one on my power supply. Is there an adapter I can use? Or will I have to go buy a new power supply for a NEW computer..?
Depends - what are your system specs? Impossible for people to help you when we don't even know what hardware you're running. Don't ruin your new graphics card by putting it ; 1. On a power supply without enough wattage to handle it, and 2. On a power supply that didn't come with cables for a graphics card. Chances are you should invest in a bigger power supply. I would recommend at least 550w for a GTX550Ti. I recommend Corsair and XFX power supplies, as well as Seasonic.
Q: need to buy for sharp aquas 52 inch flat screen
It's a universal AC power cord. The same one you would use for most other flat panels, desktop pcs, and the PS3. Go to your local Best Buy. They have them in 2 places: Playstation 3 accessories or the PC cable isle in Computers. $10 give or take a couple bucks.
Q: is it possible to run a 2-wire AC power cable (2x2.5mm2 or thicker) from the telephone junction box to the inside of the house instead of using an ordinary thin phone cable? will that affect the voice quality or maybe an ADSL setup? the distance is approximately 50 meters.thanks a lot.
Two conductors are two conductors, unless there are high-frequency issues. In this case it appears that if you are replacing parallel (not twisted) wires with another set of at least equal thickness, you should be okay. Since ADSL is used on parallel wires, without twisting them, the frequencies conducted should not present problems.
Q: Can I do the big 3 upgrade by only doing the 2 ground cables(battery to chassis and engine block to chassis) now and doing the power to the alternator at another time? Will this give me a little performance boost until I can get enough material?
Yes, that is fine. That is what i did in my car because it was a pain to get to the alt and i had a new one on the way. My voltage was dropping to around 13 volts before i upgraded the two grounds and after it never dropped much past 13.5. It is more of a problem to upgrade power cable and not the grounds, not to upgrade grounds and not power.
Q: So I have a subwoofer in my trunk and was wondering if I could use the big power cables (coming from my battery) going into the amp (which is a JL Audio JX1000) to power some LED's that I want to install. My plan was to cut out a small section of the rubber sheath (or whatever you call it) from each power cable and put the clamps from a power inverter on them, then plug my LED's into the power inverter. After putting the clamps on I would use electrical tape or something to cover any exposed areas of the cable. Would this work? If it does work, which color clamp (black/red) would i put on which cable? One says quot;groundand is blue and the other says quot;+12VDCand is red. Also I have a toggle switch near the driver seat to cut the power from the amp so the LED's won't be left on after the car is turned off. Let me know if I'm leaving out any further information needed to answer my question.
You okorder /... Your power inverter, I am not sure what kind of cabling it will require for it to be powered properly as well. Ground is usually connected to Black. And +12v is usually Red.
Q: Excuse me, what is the difference between submarine power cables and general buried power cables? What is the difference between the calculated current carrying capacity of the submarine power cable and the general calculation of the current carrying capacity of the cable? More
Submarine cables and ordinary power cables are used for power transmission, the general power cable in general steel armored after squeezing the outer jacket can be, the submarine cable in the outer jacket outside the cover and mixed with asphalt Steel armor layer to increase the mechanical strength and corrosion resistance when laying. Electrical technical parameters and the same as the ordinary power cable, the main consideration to provide cable laying when the submarine channel conditions and the sea environment. Another large length of the submarine power cable also consider the cable intermediate connector technology is reliable (in case of accidental damage or body failure). The difference between the submarine cable and the cable are said, if the need for submarine cable, in addition to the basic provision of electrical performance and other parameters need to provide laying environmental factors such as buried depth, sea water temperature, sea soil thermal resistance coefficient The
Q: Have a 480 volts 3 phase 16 amp motor. Need 400 ft of extention cord. Is is OK to use a SOOW 10/4 cable, the voltage drop is 2.67%(12 volts). Machine is powerd by a generator that I can run at 500 volts to counter the voltage drop.8/4 cable cost twice as much, but the voltage drop is 1.7%(8 volts).
I suppose this may work, just remember make sure you don't overheat your cord, and your motor runs ok with this setup, over or under voltage is hard on a motor. try using a volt meter on the motor while under load in order to find the proper voltage for the generator, that % is calculated and may not be acurate in real life.
Q: Hi All, i have a star sound 1200w 4way amp which i want to use just for my sub for the meanwhile as im waiting on a monoblock, please tell me if i can install the amp without the fuse that connects straight on the power cable?? and what is the main reasons for that fuse? thanks in advance
Could you install it without a fuse. Yes. Should you install it without a fuse. No. If your power wire ever got shorted out it would melt and catch of fire. Their have been cars that burned to the ground because they did not have fuses.
Q: The question above relates with the Transpose Line.One of the subtopics under Transmission Line Parameters in Power System.
If the adjacent line induces current in a nearby cable that would be a problem. Transposing results in one section having an induced current with a certain phase but the next section (after the transposition) has an induced current with the opposite phase. Over the length off the cable, the opposing induced currents will cancel each other out.
Q: What is the difference between a power cable and a cross-linked cable?
If there is a number of casing is the number of lines marked, if the line before the iron circle is a small nose, line nose in addition to a small circle and fork, and fork almost look.