As connecting wires of all kinds of electrical instruments and automatic devices to control, monitor and protect circuits of AC.

Specification :

1.Better quality & Faithful business

2.Prompt delivery & reasonable price

Plastic Insulated control Cables are used for rated voltage up to and including 450/750V

The long-term operating temperature of PVC insulation cable conductor should be lower than 70°C,and that of XLPE insulation should be lower than 90°C

The installing ambient temperature of cables shouldn’t be lower than 0°C,the Min. bending radius of installing is 6 times of the outer diameter

Unarmored control cables

Such unarmored control cables are suitable for laying indoors and in the electrical cabinets, however, the cables can’t bear larger external mechanical forces.

PVC sheath has stable property and excellent chemical corrosion protection characteristics, also with the features of non-fire propagation and non-water absorption, which greatly ensure the cables’ service life.


Control cables with steel wires armored

Steel wires armored control cables can endure certain mechanical tension, which are widely suitable for high-level difference environment, also can be installed vertically

Cables with screen have good shielding and anti-interference performances.
Control cables with screen

Generally speaking, there are two ways of copper wires braided screen and copper tape wrapped screen for control cables, however, copper wires braided screen has stable structure, the effect of screen won’t change with the cable bending or appearance factors etc, but also doesn’t have influence on cables’ flexibility, braiding density can reach over 80%, besides,copper tape wrapped screen percentage of coverage can reach up to 100%.


The specific models see the  Annex 2

Annex 2: LSZH-XLPE/ Irradiated Cross-linked Insulated Control Cables

WDZ-KYJY

WDZ-KYJ(F)Y

Copper conductor, XLPE/radiated crosslinked insulation and Polyolefin sheath flame retardant control cable with LSZH

For laying in doors and in ducts, the cable has property of flame-retardant with high requirements of safety and environment-friendly cables.

WDZ-KYJYP

WDZ-KYJY(F)P

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper wires braided shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJYP2 WDZ-KYJY(F)P2

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper tape wrapped shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJY23

WDZ-KYJ(F)Y23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and steel tape armored control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP23

WDZ-KYJ(F)YP23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper wires braided screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP 2-23

WDZ-KYJ(F)YP 2-23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper tape wrapped screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

Q: I need a replacement tip/end for my laptop power cable- specifically, the small cylindrical metal-and-black-plastic bit that plugs into my laptop. The cable and black box part of the cable are working fine, but the tip has bent and I need a new one. I'm having trouble finding any on OKorder or elsewhere because I don't know the technical term for the component to search for. Can anyone help?
this is the ac power adaptor , go on the web site for your particular make of laptop check the spec for it.it should be in the part that lists accessories.
Q: all my cables are pluged in but i have no power to printer lexmarkz43
You could also try and leave the power cord completely unplugged from the printer and your power source for about 5-10 min.
Q: i want to run a power cable from my battery from under the hood to my trunk for a amp that i want to power. i have a 94 mercury cougar. and i have seen it done under the car and through the firewall into the cockpit, if i want to run it through the firewall which way do i put it through? can someone send me a link to a pictured instructions? or just tell me how? thanx
Look for a grommet around the steering column or brake pedal. Using a screwdriver from inside the car, poke a hole and with a piece of coat hanger, tape your wire to it and pull it through towards the engine side. If you can't find a grommet, drill a hole and put a grommet in.The center of the grommet should slide easily over the wire and drill the hole the same size as the grommets outer diameter in the groove. The fuse should be no more tha 18 from the battery. _______ (sigh) Technically, running your RCA wires and power wires shouldn't cause any problems and can be dubbed a myth. However, a lot of people will disagree. For induction between power and signal wire to occur, a form of AC (with some current) must be introduced on the DC power wire. The signal throught the RCA cables, doesn't have enough current to do this. However..... One solution, if you want to run them together, is to have good shielded RCA cables and/or to separate the RCA wires and twist them (as in twisted pair wire, twisted pair wire is used in CAT3, CAT5 and CAT6 communication wire to eliminate noise/interference/induction). Another solution is distance, you don't have to have cable on both sides of the car as a 1 foot separation will do just as good.
Q: I need 300 ft. of service entrance cable and I've been told I need 4 guage 3 wire 200 amp aluminum is what I need but I'm wondering if this 1 guage overhead line would work just as well if buried in 2electrical pvc conduit for 300 ft.
When you say 4 gauge it is unclear whether you mean #4 (rated for 80 amps) or 4/0 AWG which is rated for 200 amps. Also, I've not seen a 1 gauge overhead line. Now then, that being said, if the cable you have is a triplex in that it is three conductors braided together, then I assure you, it would be a nightmare to wrestle that 300 feet in a pipe. Secondly, your voltage loss could be great enough that you would want to probably up the wire size to 250 MCM cable which would require a larger pipe. As an answer, the plan that you currently have is going to cause you more problems than it's worth. If I can be of further help, feel free to contact me personally.
Q: Excuse me, what is the difference between submarine power cables and general buried power cables? What is the difference between the calculated current carrying capacity of the submarine power cable and the general calculation of the current carrying capacity of the cable? More
It is the audio cable connection is not good, you check the line and the machine at both ends of the socket is rusty, for the new line can be. In addition, the TV volume will be reduced, the set-top box volume can be filled!
Q: How to test internet cable through home power plug, stead of internet tester?
DO NOT DO IT! = Household power is deadly! - At least, household power will fry cables anything connected.
Q: I have a desktop PC that when turned on the fans works but it won't beep or display anything on screen. But after I unplug both motherboard power connectors and plug them back in, the PC stats working normally, why is that? Oh, and I tried disconnecting only the external power cable, no luck.
nicely it relies upon, feels like a heating concern... Your power furnish ought to have a fan on it, seem and hear be sure that is going, using fact it sounds like it is no longer, if thats the case you will the two ought to do some extremely tedius artwork removing the ability furnish and replaceing the fan, or purchase a sparkling one... yet once you particular the psu you examined it with works and the pc nevertheless didnt boot, nicely then it must be greater, be sure all followers and what no longer come on and attempt it
Q: What is the difference between a YJLV cable and a VLV cable?
. you want to achieve remote switch, right? In fact, from the host side of the original fixed switch button that cut the two lines, and then then you need to extend the extension cable you can, the super simple; . Internet cafes router, through the exchange (or hub) , Can achieve port expansion capabilities, you can access a lot of computers, but the Internet speed is limited by the router exit speed, that is the maximum speed will not exceed the router exit speed, and broadband providers will be on the server side of the uplink and downlink speed (That is, to provide customers with the speed) restrictions.
Q: It's not the original power cable but it's going to my current DVR.
The cable will work just fine.
Q: Well I guess the more general question is:Are quot;twin power cablescompatible with 12v accessories and motorcycle batteries to make a safe running circuit?
This is absolutely possible. I would be careful about the weight of cable you use, ensure that it can carry the amp rating of the accessory you want to power from the 12v accessory socket. For example if you're powering a heated vest these can be rated at up to 25 amps. Maplin have a good range of cables at various A ratings. I would also advise you crimp and heatshrink rings onto the cables that you can clamp onto the battery terminals. The Anchor ones are excellent, but Maplin will stock a range of options. You may want to think about wiring an inline fuse, and/or a switch to prevent overheating, and to protect your battery. Hope this helps.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords