Pipeline Ball Valve-Reduced Bore High-Performance PN 25 Mpa
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 100 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
pipeline ball valve-reduced bore High-performance
Product Description of High-performance pipeline ball valve-reduced bore:
High-performance pipeline ball valve is Raymond(RMD)hightech products,as switch control equipment,it is mainly used in natural gas,oil,gas,liquefied natural gas pipeline transmission system and other industries,its anti-sulfur products containing hydrogen sulphide,impurities and high corrosion are suitable for the long-distance natural gas pipeline.
Design Features of High-performance pipeline ball valve-reduced bore:
Body of high-performance pipeline ball valve is forged structure.The connection type for body and vice-body can be BB(bolted connection)and WB(welded connection).The WB(welded connection)and the LWB(Fully-welded extended stem)structure isadopted for buried ball valves,as shown below.
High performance pipeline ball valve series has the feature of strength, high perfect sealing, maintenance-free, long life and so on. The production of this series ball valve adopts the international advanced ball valve design and manufacturing technology, selects high-quality materials in accordance with the standard selection of materials and combines with advanced materials forming forging technology. At the same time, with the years of ball valve design and manufacturing experience, the use of advanced processing and manufacturing equipment and production and processing technology, through the first-class inspection and testing equipment and instruments, perfect quality assurance management system and excellence in the production of high-performance philosophy can ensure the quality of valves. This series of valve has the performance of a high strength, defect-free forging body, excellent sealing performance, even at maximum pressure difference(full pressure),it will still be able to ensure that seal without leakage, after frequent switching action to realize a safe usage in the transportation of oil, natural gas, coal gas, and other special medium transportation pipeline.
The special structure of valve seat seal of High-performance pipeline ball valve-reduced bore:
Floating structure means seat reciprocally can move along channel direction,so as to guarantee the ball and seat are tightly sealed.
(Ⅰ)Valve seat structure suitable for different occasions and sealing requirements
Valve seat can be designed as a standard single-piston effect and specific dual piston effect,Figure1 shows single-piston effect-inletside seal;Figure2 shows Dual Piston effect-outlet-side seal;Figure3 shows special dual piston effect sealing structure
(Ⅱ)Multi-level structure of the valve seat seal
As shown in Figure4,there are two elastic O-ring in the valve seat ring-ring A and ring B.Sealing ring A spring-loaded through the valve seat so that the sealing surface of sealing ring A tightly fit with ball surface to form an initial seal.When there is pressure in the system medium,the piston force
produced by the piston force produced by the piston effect of size difference makes elastic deformation of the ring A Ershi sealing surface and ball more closely fit the surface to form a re-sealing;meanwhile,due to ring A in the medium resulted in elastic deformation under pressure so that the sealing ring B is also closely fit the surface of ball for the formation of the second stage seal.When the system medium pressure increasing,it will have an enormous pressure in the valve seat ring A and ring B,so that the two seals have a greater elastic deformation,and then the metal valve seat ring surface and the ball surface sealing together to form a third level of metal to metal seal.
(Ⅲ)The assisted valve seat sealing equipment
Based on the actual service condition,medium requirement,sealing requirement,etc.,the assisted valve sealing equipment will be considered to be necessary or not.The assisted valve sealing equipment is a one-way valve installed outside of valve body that can prevent medium leakage and can inject sealing grease into valve body by external force.When the assisted valve seat sealing equipment is required,valve seat ring shall be design and processed with injection grove and hole to connect the assisted valve seat sealing equipments.Such equipment can prevent the medium by the sealing of injection of rease.Refer to Figure5 for reference.
Multi-level structure of stem sealing
Figure6 shows the stem multi-level sealing by adopting"O"ring,flexible graphite and grease injection;"O"ring achieves the first level stem sealing;Replaceable flexible graphite realizes the second level sealing by the compression of packing sleeve and packing flange;And the third evel sealing is realized by installing assisted sealing injection valve to the packing box,and by designing with the injection groove and hole to connect with the stem injection valve,which can inject grease.
Unique and safe seat structures of High-performance pipeline ball valve-reduced bore:
Ball valve fireproof design is implementation of the API607,API6FA standards.According to service conditions and user requirements,ball valve can be designed as a fireproof structure.
(Ⅰ)Fireproof structure of seat
As shown in figure7,there is composite fireproof ring,which are combined with graphite and stainless steel wire in the seat.Once the soft ring is burnt out in case of a fire,the fireproof ring and seat ring will form a piston structure through the spring to load the valve body.That will push and closely contact the metal seal surface of the seat ring to the body surface,So as to prevent a lot of medium from leaking from the burnt place of the seat ring,and prevent the fire from expending.
(Ⅱ)Fireproof structure(body and bonnet)
The seal gasket for bolt connecting valve body and valve bonnet,are used fireproof stainless steel wire and flexible graphite gaskets.Gasket compression load through the bolts and ultimately,ensure the valve body and valve cover between the metal to metal contact,so that the valve can with stand more high load,but also improve the fire safety of the valve.But for the full welded ball valve,the valve body and cover is welded structure,that fundamentally eliminate the possibillity of leakage of the valve housing.Even in the case of fire damage,there will be no leak.
(Ⅲ)Fireproof structure(body/packing and stem)
The body and packing connection gasket adopts fireproof stainless steel wire and flexible graphite gaskets.The stem packing adopts flexible graphite to ensure no leakage in case of fire.
Standard of High-performance pipeline ball valve-reduced bore:
Design Standard | API 6D customize |
Connection Standard | ASME B 16.25-2007 ASME B 16.5 ASME B 31.4 ASME B 31.8 DIN GB、GB/T JB、JB/T JIS customize |
Test Standard | API 6D customize |
Face to Face | API 6D customize |
Pressure-temperature rating | ASME B 16.34-2004 customize |
Marking | MSS SP-25 customize |
FAQ of pipeline ball valve-reduced bore:
Q1:I can’t find the type of steel check valve which I need. what can I do?
The chart above only lists out some common composition of steel check valve parts.We may provide other different parts material composition according to the customer's request or the actual valve working condition.
Q2:Which certification do your products pass?
Our products are in accordance with ISO 9001、ISO 14001、API 6A、API 6D、TS CE、API607/6FA/BS6755.
Q3:How can I place an order?
The only one thing you should do is to tell us the sepecification about type 、quantity and mode of transportation, then we will send you quotation within 24 hours.
- Q: What is the International Standard or other acceptable calculation or table for determine the air supply of pneumatic actuator in shutdown valve 6 to 24.Desired answer will be air flow in SCFM.Thank you.
- Shut down valves I've worked with haven't had an 'Air Flow' for their operation. For the smaller valves, they consist of diaphragm operated valves either held open or closed by pneumatic pressure. The air supply at 25psi to give a diaphragm holding pressure of 15 psi, is via a solenoid valve which dumps the air pressure to either open or close the valve depending upon its function. (That of isolating a system or relieving pressure). The solenoid is actuated by a signal from the shut-down system, and the valve is a 3-way unit which isolates the supply air and vents the pressure off the diaphragm. Other SDV's in my experience, are operated in a similar way but are much larger and are operated by a pneumatic air cylinder and piston with air supplied at 100 psi. Others encountered are ... MOV's...Motor Operated Valves that can be automatically operated from the shutdown system, or Operated Remotely from a safe distance (ROV's).
- Q: How do I test to see if my gas valve on my wall heater is working or not? Please don't respond and say call a pro.
- There's a rubber diaphragm inside the water regulator it must be deforming cause of water condition . By changing that washer will start work. I recommend call a pro to do that.
- Q: In my condo, I have what appears to be a water relief valve of some sort right after my water inlet pipe. It's after the water cutoff valve. It's not the water heater relief valve. It has a leak, not bad, just a drip right now. It looks like a half baseball sticking out of the main inlet pipe with a bolt in the center of it. I've tried to tighten it but that makes the leak worse. First, what is this. Second, Is there an obvious fix to this. Third, if I have to get it replaced, what model/manufacturer can I get so that this doesn't happen for a long while. My plumbing is short of fifteen years old.
- It sounds like a cold water relief valve, also known as a thermal expansion valve. It leaks when your city pressure exceeds 100psi (factory setting) or the set pressure. Code requires pressure to be below 80 psi. A Watts 530C will do the trick. It is adjustable. It will cost you about $30.00 - $40.00 + labor to remove old install new. If it is a pressure reducing valve, a new one will cost about $125.00. It lowers your pressure when it exceeds max allowable per the plumbing code, 80 psi here in Florida. I use the Watts 1 25AUB-Z3 Pressure Reducing Valve for these applications and set it at 60 psi.
- Q: The valve on my mountain bike tire has a leak, so I want to go buy a new valve (and maybe a couple spares)... how much is the average cost?Thanks!
- Pump the tire up to max and then release the air that may clear any dirt out. If it's leaking around the base it needs patched or replaced.
- Q: I recently adjusted the valves and put new valve covers on my bug and now I have a leak around the fron corner of one of my valve covers. What happened? What can I do?
- probably the gasket slipped or the bolts need to be tighten more but just snug them down.
- Q: When i disconnected my Diverter Valve and made it non-recirculating i drove down the street and my engine cut out on me. it will go a few feet and after the excess pressure is released (PSHH) the car cuts out. i reconnected the valve tubing making it rec-circulating and it works fine. im baffled i know VW is supposed to run a DV but last night i saw a stock VW GOLF running blow off and he was stock. any ideas? it is an after market DV made by forge.
- The OEM valve has a very low spring rate against the diaphragm holding the plunger down. The very first time you released the throttle the engine vacuum easily held the valve open. When not in boost the open valve will become an intake leak because its bypassing the MAF (mass air flow) sensor. If the MAF reads very low air coming in through the it, the ecm will start lowering the injector pulse width until it cant compensate any longer and will cut off because of the air leak. The Golf was running a higher spring rate to keep the valve closed at idle or has a chipped ecu to be able to release to atmosphere. Hope this helped out.
- Q: the ac replacement valve seems to be leaking i was wondering what is the average cost of having it replaced..
- The ac replacement valve? Well, what you can do is to get the new ac to replace the old ac.
- Q: I was diagnosed with Mitral Valve Prolapse when I was 18. I am 23 now and feel like my symptoms have only gotten worse. Sometimes I could just be still and have severe chest pains with slight paralysis in my arms. It's like my body locks up from the pain. Recently I had an episode and I immediately started crying from 3 seconds of severe chest pain. For the past three days I've had this headache in my temples that sends a slight numbness down my jaw. I didn't know if these symptoms were in any way related to my MVP. I'm going to see the doctor today and plan on mentioning it. Does anyone have these same symptoms or an idea of what is wrong?Thank you!
- Although mitral valve prolapse is a lifelong disorder, many people with this condition never have symptoms. When diagnosed, people may be surprised to learn that they have a heart abnormality. When signs and symptoms do occur with mitral valve prolapse, it's typically because blood is leaking backward through the valve (regurgitation). Symptoms can vary widely from one person to another. They tend to be mild, develop gradually and may include: A racing or irregular heartbeat (arrhythmia) Dizziness, lightheadedness Difficulty breathing or shortness of breath, often when lying flat or during physical exertion Fatigue Chest pain that's not associated with a heart attack or coronary artery disease When your heart is working properly, the mitral valve closes during contraction of the left ventricle to prevent blood from flowing back into your heart's upper left chamber (left atrium). But in some people with MVP, the mitral valve malfunctions. In these people, the mitral valve leaflets are abnormal with extra tissue, bulging (prolapsing) like a parachute into their left atrium each time the heart contracts. The bulging may keep the valve from closing tightly. This may not cause problems if only a small amount of blood leaks back into the atrium. When blood leaks backwards through the valve, it's called mitral regurgitation (MR). MR can cause symptoms. Take care always! OIRAM
- Q: Hi everybody,I need some information about the operation of a double solenoid valve and how to control it using a PLC
- A double solenoid has two solenoids, and when voltage is supplied to one (and not the other) the valve shifts. Note that if voltage is supplied to both solenoids at the same time, the valve will stay in the position is was in (i.e. it won't shift since the solenoids will be working against each other). This is typically not desired, so make sure you remove voltage from one side when supplying it to the other. If no voltage is supplied to either solenoid, the result will be the same as if voltage is supplied to both, in that the valve will stay in the position is was in. What this means is that the cylinder has no home position, so when power is cut, the valve will stay where it was at that time, and the cylinder will continue to do work in the direction is was working in. Again, depending upon what the cylinder was doing, this may or may not be desired. For Conrolling with PLC you may need to wire two discrete outputs of PLC to those two solenoids using relay. And the ON/OFF those two outputs as required.
- Q: I want to find a cheap valve that will let me take a breath in from one place then exhale through a tube going out so that i can attach an airbag to the breathing end and make a little diving lung.
- Creating a proper valve system for the creation of a diving lung is not as simple as you think. You require carefully balanced directional pressure regulation valves. A simple one-way valve (AKA check valve) would remain open and release all the air from the airbag as soon as the airbag was subjected to water pressure.
Send your message to us
Pipeline Ball Valve-Reduced Bore High-Performance PN 25 Mpa
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 100 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords