PE physical foaming insulated coaxial RF cable SYWV(Y)-75-12
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product properties:
Uses: This product is applicable to shared antenna systems, closed circuit television system and other signal transmission, and such cable has the characteristics of small attenuation and strong anti-interference
Structure and size of YWV (Y) PE physical foaming insulated coaxial RF cable products
Items | Sizes | ||||
SYWV(Y)-75-5 | SYWV(Y)-75-7 | SYWV(Y)-75-9 | SYWV(Y)-75-12 | ||
Inner conductor diameter | 1.00±0.02 | 1.66±0.02 | 2.15±0.03 | 2.77±0.03 | |
Outer diameter of foaming medium (insulator) | 4.80±0.20 | 7.25±0.20 | 9.00±0.25 | 11.50±0.30 | |
Outer conductor | Aluminum-plastic composite belt or aluminum foil + tinned soft copper wire braiding, and the nominal diameter when the tinned copper wire is used in braid | 0.12~0.15 | 0.12~0.15 | 0.12~0.18 | 0.12~0.20 |
The maximum diameter braided angle of outer conductor ≤ 45 °, filling factor of 0.23 (minimum) | 5.8 | 8.3 | 10.1 | 12.6 | |
Jacket | Thickness | 0.70 | 0.85 | 0.96 | 1.00 |
Outer diameter | 7.2±0.30 | 10.3±0.30 | 12.2±0.40 | 15.40±0.40 | |
Delivery length | Length of each volume | 100 | 100 | 200 | 200 |
Short break | 20 | 50 | 50 | 50 | |
As for length of each conducting wire of -7, -9, -12, the order requirements shall prevail |
Electrical performance of SYWV (Y) polyethylene physical foaming insulated coaxial RF cable products
Items | Sizes | ||||
SYWV(Y)-75-5 | SYWV(Y)-75-7 | SYWV(Y)-75-9 | SYWV(Y)-75-12 | ||
Core cable dielectric strength | 1.6 | 1.6 | 1.6 | 1.6 | |
Insulation Resistance 500V DC > | 10000 | 10000 | 10000 | 10000 | |
Sheath dielectric strength | Spark test | 3.0 | 5.0 | 8.0 | 8.0 |
Water immersion test | 2.0 | 3.0 | 5.0 | 5.0 | |
Characteristic impedance 200MHZ | 75±3.0 | 75±2.5 | 75±2.5 | 7.5±2.0 | |
Voltage decrease constant | 50MHz | 4.9 | 3.1 | 2.6 | 2.0 |
200MHz | 9.9 | 6.5 | 5.2 | 4.1 | |
550MHz | 16.8 | 10.7 | 8.5 | 6.7 | |
800MHz | 21.0 | 13.9 | 11.5 | 92 | |
Return loss | VHF | 20 | 20 | 20 | 23 |
VHF | 18 | 18 | 18 | 20 |
- Q: What is the power cable accessories used to do?
- The shield has two types of semi-conductive shield and metal shield
- Q: I'm gonna be running a 2,700watts RMS system on a Power Acoustik 4,500watt Class D Monoblock amp at 1-ohm. I have a 2005 Impala LS do I'm going to need a secondary battery. What size should it be? Also what size power wire and ground wire should I use? I'm going to be using 8gauge speaker wire. Any help is appreciated. Thanks!
- I okorder /
- Q: Copper and Aluminum are being considered for the cables in a high-voltage transmission line where each must carry a current of 50A. The resistance of each cable is to be .15ohms per kilometer.A. If the line carries power from Niagra Falls to New York (500Km), mow much power is lost along the way in the cable? Compute for each choice of cable materialB. the necessary cable diameterC. mass per meter of cable Please correct if you see anything that may be offSolving for part a:Power = I deltaV, since deltaV was not given IR=deltaVso Power = (I^2)R = 50^2 x 75 = 187.5 kW lt;-- answerR= 75 since R= .15 ohms/ km x 500kmB) resistivity of copper = 1.7 x 10^-8 ohm m resistivity of al = 2.82 x 10^-8 ohm m R = (resistivity x length)/Areawhat do i use for R? is it the 0.15 ohm/km or 75 ohm?using the 75 ohm as R, I get that the radius of the copper wire is 0.0000361 m and the diameter is then 0.0000722.Am i on the right track?
- a three middle 1100 volt cable will choose an insulation resistance of two to three meg-ohms making use of a 1000volt megger tester. the rule of thumb is the cable must have a minimum of one million meg-ohm in preserving with kv score.
- Q: Last step to install my amp is the Power Cable. Their is a fuse device i must attach to the cord so im guessing i have to cut the gauge install it on both sides and run it to the battery. Does it matter were this fuse device connects? because i want it right next to my amp.thnx
- The fuse should be within 18 of the BATTERY!!! I cannot stress this enough. Amplifiers have built in devices which protect the amp, the in-line fuse's sole purpose is to protect the wire in case of a short. Put that fuse close to the amp, and all of that wire feeding from the battery is unprotected; and any part of that wire that shorts to the car can, and continues to pass current to the chassis, until something catches fire due to the tremendous heat created from the short. Mount it as close to the battery as possible.
- Q: Low voltage power cable telemetry insulation resistance, the number should be used to shake the table? The More
- ZR-KVVRP-500 is mainly used for transmission control, measurement signals and other cables. ZR: Control cable KVVRP: PVC insulation 500: Rated voltage 500 V or less 1 × 2: Two core 1.5: Wire diameter
- Q: I found a box of power cables that I could use to hook up my PC and I know some of them were for old CRT monitors. Is it safe to use any of them? I'm not sure which one actually came with the monitor.
- From what I can tell, all of the monitor power cables are exactly the same. I don't see any reason why they wouldn't work or why it would be unsafe. As long as it fits easily into the LCD and plugs into your power supply then it should be just fine. (P.S. I've used old power cables on newer models before when I lost a cable once)
- Q: I have an old school Soundstream 500s amplifier(500 Watts) and I want to put it in my 1965 Mustang Coupe. I want to have a small but clean sounding system for the old car, probably with two small subwoofers too. I need to get all new cables for this sound system, so what would be a good power cable for the amp? I need roughly about 25-30 ft. of cable just to be safe and a fuse as well.
- Every okorder /
- Q: hello guys,how does a power boost cable works?what is the difference between a usb cable and power boost cable.
- It is simply a 2nd USB for power alone, it does not use both USBs to transfer files, just one, the 2nd is just for additional power to improve the performance of the hard disk
- Q: And can u please explain in detail how u get xbox live i dont want any free survey things just like do i have to buy a card how much it is do i need extra cables? ok thx!
- for the original xbox thats right, OK first step: 1: get an ethernet cable 2: get a DSL modem 3: Hook up modem to wall 4: hook ethernet cable to back of xbox 5: go to the dashboard thingy,(dont know what it is on original) 6: go to xbox live and purchase it.
- Q: I bought a TV and it requires 9 amps but it didn't include the cable. I have a 7 amp cable that fits, but I don't want to damage the TV. All the cables at stores around me don't fit well. Could I get away with just using this one for a couple days until the right one arrives in the mail? I can imagine that it wouldn't give me reliable power, but I don't really care about that, I just don't want to damage the power supply of the TV. Thanks in advance.
- You have a TV that draws 9 amps from a 117 v.a.c. power line? That's roughly a kilowatt. You could run three 55-inch LED sets for that, with power to spare. Or does your TV operate from a 12-volt d.c. source, like for a boat or RV? That would make more sense, 108 watts total. In that case, using the wrong power cable could be at least a theoretical hazard. I'd wait for the proper cable. If you'll update your post with the make and model of your TV and what you're powering it from, you might get a better answer. Your location would also help, at least which country due to different a.c. power systems. ----------------------- Followup, per your added details: now I get it--you have a power cord that's rated at 7 or 9 amps, not a TV that draws that much. That's entirely different. Your TV/DVD combo will use a maximum of about 150 watts, which means it will draw just a little over one amp. So any power cord you can find that fits properly and is rated at something like 3 amps or more will be fine.
Send your message to us
PE physical foaming insulated coaxial RF cable SYWV(Y)-75-12
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords