MS/MSS Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Pump Applications:
Cooling water
Domestic water/supply
Sprinkler systems
Agriculture
Boosting & circulation systems
Water treatment
Performance range
Capacity: Q up to 27 m3/h
Head: H up to 40m
Max operation pressure: 8bar
Liquid temperature: -10degree Celsius to 85degree Celsius
Speed: N 2900rpm or 3500rpm
Power: P up to 2.2kw
Standard material
All the parts contact with liquid made of 304 stainless steel.
Mechanical seal are standard supply.
Description
Hydraulic parts
All stainless steel horizontal single stage not self-priming pump with axial
Suction, vertical discharge threaded connections.
- Q: Pump adapter belongs to the system of fire pool equipment?
- Not belong to. According to the specification, fire hydrant system and automatic sprinkler system fire water supply pipe should be installed on the pump adapter, therefore, it belongs to the fire water supply facilities.
- Q: We're doing some droplet impact experiments and are creating the flow of water to our droplet generators by elevating our source of water. Unfortunately as the water depletes the pressure changes. We need to siphon off the water from our lower basin where the water collects and pump it back up to the source (around 6-8 feet up). What kind of pump do I need for this?
- I presume you can’t use city water! Droplets probably mean very small water flow. You can try local used merchandise store. Often they have waterpik systems for a few $ They are piston type pump that means the output will be pulsating instead of continuous. Another option is a windshield washer pump. These are gear type, so provide a continuous flow. You would need a variable power supply to control the pump speed, therefore the flow. Good luck Hope this answers your question
- Q: How can we calculate the maximum pump pressure for chilled water system for a 20 story building
- maximum stress tanks have a bladder interior them.The air is extra to the bladder to create a cushion of air, because of the fact the stress interior the tank builds up. Rule of thumb; while the pump is off and the stress interior the device is enable all the way down to 0, there ought to be 2# below shrink-in stress on your stress swap. i.e.- in the adventure that your stress swap is a 20/40, meaning it cuts in at 20# of stress and cuts out at 40# of stress, you may choose 18# on the bladder. in case you have an previous sort tank devoid of bladder, it ought to have an air quantity administration that provides air each time the pump comes on. Any air you upload to this sort of tank will ultimately get away so which you may choose to repair the situation with the air quantity administration. that's complicated and you may incredibly choose a provider individual to try this. e mail me and that i'll enable you recognize the thank you to do it if certainly you have an previous sort, bladderless, tank. desire to help!
- Q: I have a 1969 Chrysler with a new 3 core radiator. It still has the stock water pump and I am wondering if a high volume pump would make it run cooler at higher speeds. It runs hotter when you get off the freeway. I have flushed the system and installed a new thermostat. I also replaced the fan clutch. I am at a loss of why it still runs warmer than the 180* thermostat.
- Sometimes I really wonder about Robert. Yeah, water boils at 212--AT ATMOSPHERIC pressure. But a cooling system is pressurized to RAISE the boiling point. So, ah, Robert is once again in left field. Because if you wait for it to boil over, you've probably already caused engine damage. You do NOT need a high volume pump. The 3 core radiator does NOT need more flow. The temp gauge should not fluctuate. That's the job of the T-stat--to regulate engine temp and keep it at a set point. If you're engine is getting hot at higher speeds, Check for missing baffles or cracked fan shroud
- Q: How do I know the pump pressure?
- Flow 18 cubic meters / hour, lift 100 meters, power 4 kilowatts.The pressure supplied by the pump is 1.0Mpa, which is 10 kg pressure.Is it a multistage pump?
- Q: Assuming that my water pump standard flow is 20m3/h, tolerance value requirements is + 8%, then is not traffic 22m3/h is not qualified?
- Tolerance coefficient is due in the manufacturing process, will, so each pump products are possible shapes and sizes do not conform to the pattern of the situation, and ensure the test results in the value (operating point) when compared, should be allowed to have a certain tolerance. It should be noted that these tolerances are only relevant to the actual pump and do not involve test conditions and measurement uncertainties. If the pump at a certain working point (the same lift) standard (Design) flow of 20m3/h, the actual flow of 22m3/h, indicating that the pump in the design process has unreasonable place, resulting in waste of power. Deviations from the manufacturing process usually have no positive deviation.A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
- Q: Just touch this area, a lot of places do not understandFor example, I have a water pump, for 11kw, choose circuit breaker, then what model should be chosen more appropriate, it is best to recommend a Schneider, universal DW recommend oneCan explain in detail, better, I checked online selection manual, there are many places that feel fuzzyIn addition, 37KW, 22KW, 1.5KW each choose what type?Hope predecessors give advice
- Schneider circuit breaker is not selected, I do not know how much current to drive the 11kw pump, and there is no other load?
- Q: Because the water pressure is too small, this summer with self suction pump 750W, water is big, but every time that water is used for the first time out of the water is yellow like rust, probably after the release of 10 liters will become clear, then is not, but every one hour after the water time out is rusty hair yellow, so to waste a lot of water, but accidentally brought cooked food should not be good to the body.Now come in the water is through the pump, even without electricity, partition time for the first time water will be yellow, there is no master can teach me to disassemble, which can be cleaned?. Or something else. Thank you
- If your pump is iron, it must be impossible to avoid rust, and if you replace it with stainless steel, there will be no problem.There is also a way to add a filter or water purifier at the front of the pump to make it a little better.You can change the flow parts into stainless steel, but the price may not be cheap
- Q: and it still runs about every 1/2 hr even if you are not using water. I have no leaks from the pump thought the house so I think the problem is between the house and the well. I can't hear or see any leaks in the elbows in the well. I tried to pull the foot valve up but can't get it out. I replaced the pump cause it was worn out and it was running every 15 min. Do I need to set the pressure on the new one it cuts off at 42 and on at 20 psi and what else could cause it to run when it shouldn't? I know I should call a plumber, but haven't worked in months and can not afford one.
- Could be the check valve in your holding tank is allowing it to bleed the pressure back into the well thru the pump and once the pressure regulator drops to cut-in press the pump runs. Get a chair and watch the pressure gage.
- Q: 89 Dodge van overheats, no water leak, replaced thermostat but still overheats.
- A water pump shows signs of dripping through whats called a weep hole on the underside of the water pump.