Commercial Galvanised Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Q: I just removed a Australian light switch that I've never seen before that controlled a bathroom ceiling fan and the bathroom light. (both buttons on a single panel switch)I have a black wire coming from the switch box that has 2 other black wires splitting out from the connection point, one of each going to the fan and the light. And a single black wire going to the ceiling fan and a red wire to the light.I'm just putting in your everyday off/on switch one for each the fan and the light. any help? what are the positive and negative wires?
The one that has a flat is the negative the one that has the bump is the positive! Hope i helped!
Q: Two wires are placed parallel to each other. What would be the effect of passinga) upward current through both wiresb) an upward current throgh one wire and a downward current through the other.Explain.
a) When the currents through both the wires are in the same direction, the magnetic field due to each midway between them, by right-hand thumb rule, will be in opposite directions. This will result in attraction between the wires. b) When the currents through both the wires are in the opposite directions, the magnetic field due to each midway between them, by right-hand thumb rule, will be in the same direction. This will result in respulsion between the wires.
Q: Hi I have a ceiling fan/light to put up but after taking down the original rose, I am now unsure how to wire the existing wiring into the ceiling fan the wiring is a s follows:block 1 Live empty,red,red, block 2 loop all empty, block 3 neutral empty,black,blackthe connections on the fan are live neutral and earthGrateful for any help
Call in a professional. Death only happens once in your lifetime. you don't want to go down in a shower of sparks.
Q: I have installed a new wiring harness on my trailer, and two new LED trailer lights. The tail lights work, both turn signals work, but for some reason, I do not have a brake light on the right side. Both lights are grounded to their own post, and I do have a good ground on the coupler of the trailer. If a turn signal and brake light in a 4 wire system are using the same wire (green in this case)- how can one work, while the other is not? Any good ideas? I really appreciate the help.
all sound good, but try checking your fuses also. some veh. have a different fuse for each side, and trailer lights may be separate also.
Q: I am in the process of installing a new thermostat, but I ran into the problem: new thermostat has 4 ports W, Y, R and G. But the old thermostat has 5 wires: W, Y, G and B. I am not sure where B wire (black color) should go. Do I need to look for another thermostat that has a port for B wire?
The black wire should be for ground. You and try to connect it without the black first to see if everything works ok, if it does tape off the black and tape it to the other wires. If not look at your UPM diagram and see which port is for ground and it should hook up with that wire. But I would double check with the heat pump wiring diagram to see what that black goes to and verify that wire with a multimeter.
Q: If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm.What is the tension in both wires?
The tension in both wires.? If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm. What is the tension in both wires? In the triangle ABC, AB(c) = 100 cm, BC (a) = 50 cm and AC (b) = 75 cm 2s = a+b+c = 225 cm s = 112.5 s-a = 112.5 - 50 = 62.5 s-b = 112.5 - 75 = 37.5 s-c = 112.5 - 100 = 12.5 tan A/2 = √ {(s-b)*(s-c) / [s*(s-a)] = √ {37.5*12.5) / [112.5*62.5] A = 28.95? tan B/2 = √ {(s-c)*(s-a) / [s*(s-b)] = √ {12.5*62.5) / [112.5*37.5] B = 46.57? C = 180-28.95-46.57 =104.48? --------------------------------------... 46.57? is the angle between horizontal and 50 cm wire. 28.95 is he angle between horizontal and 100 cm P is the tension in the 50 cm wire and Q is the tension in the 75 cm wire Equating the horizontal components of the tensions P cos 46.57? = Q cos 28.95 ? P = Q cos 28.95 ?/ cos 46.57? P = 1.27 Q-------------------1 Equating the sum of the vertical components of the tensions to the weight of the pot P sin 46.57? + Q sin 28.95 = 8*9.8 N 0.73P + 0.48 Q = 78.4N 0.73(1.27 Q) + 0.48 Q = 78.4N Q = 55.72 N and P = 70.76 N ============================= Or use Lamis theorm Angle between P and Q = 104.48? Angle between P and the pot = 90 + 46.57? Angle between Q and the pot = 90 + 28.95 By Lamis theorm P/ cos 46.57? = 78.4/ sin 104.48? P = 55.67 N and Q = (78.4/ sin 104.48? ) cos28.95 = 70.85N ====================================
Q: so there are 3 different wires coming into the switch. 1 black wire and 2 white wires going to the attic fan (i assume one for high and one for low). the power seems to be coming from the black wire which has inside of it, one white wire (neutral) one black wire (hot) and one bare wire (ground).. the same for the 2 white wires. the switch goes up (^) for high and down (v) for low and has 3 places to attach the wires to. the top, the bottom and the middle.. can someone tell me how to wire this damn thing?
Attic Fan Switch 2 Speed
Q: What are the range specs when testing resistance on your spark plug wires ?
6-12 ohms? Huh That person is WAY off. Stock type plug wires will have 3,000 to 5,000 ohms per 1 foot of wire Cheap parts store plug wires may have 4000-8000 ohms per 1 foot of wire High performance wires like MSD will have 40-50 ohms per 1 foot of wire
Q: I NEED TO CHECK IF A WIRE IS GOOD ON A FITNESS MACHINE. HOW DO I KNOW IF ITS GOOD? WHAT SHOULD THE OHMS BE?
any wire, unless it is very long or very thin, will measure zero ohms on an ordinary ohmmeter. But check for continuity does not completely check a cable. Most cables have several conductors in them, so you need to check each one end to end, and check resistance between the wires. Between them, it should measure open or infinite ohms. But the cable could still be bad. Tell us the details please. .
Q: I have a JVC KD-R210 does it have a wire fore it or what do I do
The red wire off of the wiring harness for the radio is the remote wire. You need to run atleast a 16g wire(a 12 gauge wire would be best) from that red wire on the radio to the remote power input on the amp. I do not know what kind of setup and amp you have so I can not give further info, sorry.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords