Hot Dipped Galvanised Steel Wire In Small Coil
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Commercial Galvanised Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: Which wire is quot;hot, white or black?
- Usually, most Fire Alarm wiring is color-coded red and black. FPL and other fire alarm cables are usually red/black for a 2 conductor cable. If a system is wired class 1, with THHN conductors in conduit, I have seen both black and white used as the positive lead. The electricians who wire it are likely to use whatever convention they are used to. If they deal with low voltage, they could use white for + and black for -. If they are high voltage electricians, they could do the opposite. The AC service, (120V or 240V) will be wired per National Electrical Code (NFPA 70), which is black = line, white = neutral.
- Q: i recently replaced my spark plug wires on my 97' lincoln continental. i was wondering if i should get plug wire shielding for them also......thanx
- A Dodge Continental?
- Q: I have this ipod cord in my car to play music off of, and at first it started cutting out. I would move the wire in a specific spot to a position to where it would work. Then eventually it just stopped working all together, so im assuming the wires inside have been damaged. Now as i said before in a specific spot so im pretty positive i know where it is broken at, but ive never actually spliced a wire, or soldered before. This is where i need help. What tools and materials will i need to fix the wire? Also, how would i fix it? Thanks for the help in advance!
- The wires in those little patch cords and headphones and stuff are often very fine and hard to splice or solder. You could get you some wire cutters and wire strippers and a soldering iron and some electrical tape or shrink wrap and go at it, but it would probably be just as well to get another cord.
- Q: Does anybody know where on the internet i can find the radio wiring diagrams of a factory radio???
- Put a V8 in that bad boy! J/K sorry. Sounds like maybe an ignition coil, plug wire loose or bad or possibly an injector like the last guy said.
- Q: How do you attach light wires to boat trailer frame?
- The colour code for trailers is as follows, white-ground, brown-running, yellow-left turn, green-right turn and blue would be for trailer brakes if your trailer has them or auxiliary. If your adapter (on the Dakota) is hooked up properly those are the wire colours that run from your vehicle into the trailer lights and the signal lights will also be the brake lights.
- Q: I need to buy more of the speaker wire my Yamaha system came with. Its very very thin almost clear wire. What is it called and where can i get it?
- A ordinary websearch ability that the 4066 is a type no longer bought interior the U. S.. One website that had it quotes in Euros, and yet another became into in New Zealand. finding on the returned panel of the old 071, it appears that evidently it extremely is subwoofer linked to it using the comparable type of speaker wires that the different audio equipment use. yet, maximum separate receivers do no longer use that type of subwoofer connection. It additionally feels like the 071's sub is a passive sub, mutually as maximum receivers require the sub to be a powered type. So, it extremely is not going which you would be waiting to apply the 071's sub on a greater constructive receiver. The 4065 won't have the capacity to run a speaker cord linked subwoofer. specific, the Yamaha is a far greater constructive receiver. It only is smart that a receiver that expenses better than a receiver with six (inexpensive) audio equipment equipment could be the greater constructive type. The 4065 is a much better type than the 375, for this reason it expenses greater. Loudness is a mix of the means (including sparkling, no longer distorted means) of a receiver, *plus* the standard and sensitivity of the audio equipment. whilst going to be a greater constructive receiver, you will possibly no longer get plenty make the main of it till you apart from mght develop your audio equipment. it extremely is comparable to having an old tube television, and shifting from DVD to BluRay; on the old television, there'll never be plenty distinction seen, by way of bounds on the old television.
- Q: I understand how to wire sprinkler valves in theory. But in practice, how is it done. For instance, starting at the last valves in the run, the common wire is attached, but in a 7-strand wire, you may only use 3 colored wires or so. What do you do with the unused wires? Just leave them dangling? Cap them off with a grease cap? Then, as you arrive at the next set of valves, do you cut the entire strand and splice, or just cut out the individual colored wires that you need to wire those valves?
- well if you have a few extra strands in the cable, they may be used in the future if you add on to the sprinkler system with more valves. or to help troubleshoot wiring problems. no need to cap the unused wires, just cut them and leave them our company leaves enough of the wire in the valve box, to be able to pull out the connection for service. make sure you leave enough wire to service the valves and their connections easlily.. we then wrap the unused cables around the used wires and the connections. keeps the valve box nice and neat, and ready to be serviced if needed. the next set of valves, the best way is to cut the whole cable and splice them back. it is just easier. again, make sure you leave a good bit of wire in the box so you can service it easily. i work on sprinkler systems for a living. one pet peeve is when a connection is not in the valve box, but inthe ground around it, b/c some one cut the wire too short.then i will have to dig up the connnections and repair them, instead of just doing it through the valve box without messing up the customer's yard. and by the way, grease caps arent the best way of sealing wire connections. the best way for irrigation is with the orange wire nuts, and seal them with Dri-Splice. from my dad's over 20 years of expericence and my last few years, this is the best way. good luck and hope this helps.
- Q: could someone teach or explain to me how to hook up the 1st one, i do not understand what is happening there. How do you connect thoes wires to the main wire??? the distribution?
- Ok, first thing you want to do is, for each subwoofer, wire a negative and positive together. You can use regular speaker wire to do that (well you're supposed to anyway). After that, you will have a negative and positive terminal left on each subwoofer. What you need to do is run a speaker wire from each of the terminals, so you have 6 different wires from 6 separate terminals. Make note of the 3 positive wires and the 3 negative wires. Now what you do is simply twist together the 3 positive wires together, so you have 1 positive wire. Connect that positive wire to the positive terminal of the amp (if it's a 1 channel amp. If it's a 2 channel, connect it to a bridged channel on the positive terminal. Or however you want.) Do the same for the 3 negative wires. Twist them together to have 1 negative wire, and connect it to the negative terminal on the amp. Finished! That kind of wiring is called Series wiring, by the way. The other kind is called Parallel wiring.
- Q: We are replacing an older style submersible 3 wire well pump with a newer style 3 wire plus ground. I do not know where to ground the green wire? Is it necessary to extend the wire from the pump all the way to the top and ground it there or can i just ground it to the pump itself? Any ideas? First time home owner... trying to save money and not call an electrician (Im an avionics technician so I have some what of an idea what im doing.) Thanks
- It shouldn't be grounded to back to the pump, it should be brought out and grounded either with the house or a separate grounding rod.
- Q: Need to wire three ceiling fans in series
- I don't think that's safe because light fittings are not rated to carry that sort of current.
Send your message to us
Hot Dipped Galvanised Steel Wire In Small Coil
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords