• HOT DIP GAVANIZED WIRE System 1
  • HOT DIP GAVANIZED WIRE System 2
  • HOT DIP GAVANIZED WIRE System 3
HOT DIP GAVANIZED WIRE

HOT DIP GAVANIZED WIRE

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
 HOT DIPPED GALVANIZED WIRE
1、 QUALITY
  GB/T343 and other standards.
2、ZINC COATING
  GB/T15393 and other standards.
3、RAW MATERIAL
  A、WIRE ROD:1006、1008、1018、Q195
  B、ZINC WITH 99.995% purity.
4、 TENSILE STRENGTH RANGE
size(mm)
tensile strength(mpa)
0.15—1.60
290--550
0.65—1.60
400--550
1.61—6.00
400--1200

5、APPLICATION
     Wiremesh, artware, metal hose, agriculture, binging for constrction, etc.
6、PACKING
size(mm)
coil size (mm)
spool packing
big coil packing
ID(mm)
OD (mm)
0.15—0.26
6 cun
1—14㎏ axis
0.27—0.60
8 cun
1—100㎏ axis
0.61—1.60
12、14、16 cun
1—100㎏ axis
250-400
400-770
1.61—6.00
450
508
800
840
7、ZINC COATING
size  (mm)
 Min. zinc coating (g/㎡)
A
AB
B
C
D
E
F
A1
B2
≤0.25
30
20
18
〉0.25-0.40
30
25
20
〉0.40-0.50
30
20
〉0.50-0.60
35
20
〉0.60-0.80
120
110
40
20
〉0.80-1.00
150
130
45
25
〉1.00-1.20
180
150
50
25
〉1.20-1.40
200
160
50
25
〉1.40-1.60
220
180
35
30
〉1.60-1.80
220
180
70
40
30
〉1.80-2.20
230
200
80
50
40
〉2.20-2.50
240
210
80
55
40
〉2.50-3.00
250
230
90
70
45
〉3.00-4.00
270
250
100
85
60
30
〉4.00-5.20
290
270
245
110
95
70
40
〉5.20-6.00
290
270
245
110
100
80
50


     
Technological features
Applications


Q: I am replacing my old electric oven with a new one. The wires on the old oven are the same as the wires on the new oven...white, red, black, and a bare wire. The wires running from the fuse box to the junction box are...white, black, and bare wire. This is 220/240 wiring from the fuse box. The oven does require 220/240. How do I wire the new oven?
Didn't the new oven come with an installation manual? If you don't have one (maybe you got a used oven from a friend) try going to the website for the company that made the oven and find an installation manual there that you can download.
Q: Car audio wiring diagram
If you cannot get a wiring diagram for your stereo or car. It's still pretty simple to install a stereo. You basically just gotta color code all the wires. Red sometimes orange is power wire, black is ground, blue is remote the rest are speaker wires. Look for wires that are identical such as light blue light blue with a white stripe, gray dark gray with a white stripe etc.....
Q: Has anyone tried to use or experiment to use CAT5E wire on a speaker going to Home theater receiver? If none, can you suggest a good speaker wire to use on a speaker.Paradigm Monitor Series and Onkyo TX-SR606 (Speaker and Receiver)
In my opinion, stranded individual wires degrade the sound, while thin flat copper foil gives the best sonic result. The difference is truly amazing.
Q: 4.A uniform semicircular sign 1.00 m in diameter and a weight of 325 N is supported by two wires. What is the tension in each of wires supporting the sign?
Assuming the wires are vertical, connected evenly to the sign, and that nothing else is supporting the sign, then each wire carries half of the weight. T = 325 / 2 = 162.5N
Q: two straight and parallel wires are separated by 6 cm. there is a 2 A current flowing in the first wire. if the magnetic field strength is found to be zero between the two wires at a distance of 2.2 cm from the first wire, what is the magnitude and direction of the current in the second wire?
If the magnetic field at 2.2cm is zero it means that at that distance the fields produced by the two wires cancel out. At 2.2cm from the first wire the field strength is B= uI/ 2pi r ... . where u is the permitivity of free space, 4.0 x 10^-7 N/A^2 B= (4.0 x 10^-7 N/A^2)( 2 A)/ 2(3.14)(0.022m) B=( 8 x10^-7)/(0.138) B= 5.79 x 10^-6 Tesla The magnitude of the magnetic field from the other wire must be equal in magnitude at 3.8cm away (6- 2.2) and opposite in direction. Using the right hand rule (thumb points in direction of current and fingers curl around the wire to show the direction of the magnetic field) you can see that for the magnetic fields to be in opposite direction between the two wires the current must be flowing in the same direction as the first wire. Using the formula for magnetic field strength you can then determine the current needed. 5.79 x10^-6 T= (4.0 x 10^-7) I/ 2 (3.14)(0.038m) THen solve for I I= (5.79 x 10^-6 T)(2)(3.14)(0.038m)/ 4.0 x 10^-7) I= 3.45 A Therefore there is a current of 3.45A in the wire and it is flowing in the same direction as the first.
Q: i am trying to wire my aftermarket tailight, and it did not come with the plug in adapter as the original. The three wires coming out of it are glued together in a bell type casing. Pls Help!!
The wire that is hooked to the tail light BODY is the ground wire.One wire goes to the brake light switch and the other one goes to the tail light hot wire.With a test light you can determine where each one is to be hooked to.
Q: in hooking up a hot wire from the battery to a toggle switch inside a vehicle, i ran a seperate ground wire to the body, there are 2 wires coming from the unit i need to hook to the toggle switch.how do i test to see which one of those is a hot wire? i am not too smart at this. ty kindly
a test lamp, connect clamp to your known good ground then touch the pencil type end to the hot. if it lights then thats your positive. do it opposite to test for a good ground .
Q: my dogs have chewed my central air contactor wire.my ac will not cut on. does anyone knows how to replace them and where to buy replacement wires locally( i live in Dallas TX.) i would like to do it myself instead of spending a lot of money.
This should be copper wire and a splice could be made with little risk since the thermostat is a low voltage circuit in most cases. Try the local HVAC contractor for some of the type you need. There are different types ( number of conductors) for different controllers so they need to match. If you just have the HVAC contractor do a fall service on the system they can make the needed repairs and prepare the whole system for the winter. It was probably used a lot this last summer so a service is about due.
Q: Trying to wire up a toogle swithch for boat light. Have a positive and negiative wire coming from the battery. I have 2 wires coming out of the toggle switch and two wires coming from the light. What goes where? Thanks
RE: Trying to wire up a toogle swithch for boat light. What wire go were? Trying to wire up a toogle swithch for boat light. Have a positive and negiative wire coming from the battery. I have 2 wires coming out of the toggle switch and two wires coming from the light. What goes where? Thanks
Q: Why is it that some wires get hot,having electricity flow throught them,while others don't?And why is it that when there is a lot of resistance in a wire, that it doesn't get hot?Why does the length of a wire has an effect on the temperature of that wire, and how exactly?
we know that the power = i^2 *r where i : is the current through the wire. r : is the equivalent resistance of the current. so this power will be consumed in the wire in form of heat, so if the resistance of any wire increase, the absorbed power will increase. Also we know the resistance of any wire = * l / a where : - = constant, the resistivity of the matter ( copper, aluminum,... ). - l = the length of the wire. - a = cross section of area of the wire. as the length of the wire increase, the resistance will increase, so the power will increase, this lead to increase of the heat in the wire.