High Quality Galvanized Steel Wire Rope Sling For Bridge
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 100 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Description
1) Construction: 1x7, 1x19, 7x7, 7x19
2) Diameter: 0.15mm—24mm
3) Length: 10m—2000m / reel
4) Lay: right hand regular lay or left hand regular lay
5) Core: fiber core & steel core
6) Nominal tensile strength: 1270Mpa -- 1570Mpa
Steel Wire Rope | |||
Product Name | Construction | Diameter | |
Steel wire strand | 1x7, 1x19 | 0.5mm-12.0mm | |
Aircraft cable | 7x7 | 1.0mm-9.53mm | |
7x19 | 2.18mm-9.53mm | ||
Round strand wire rope | 6x7+FC, 6X7+IWSC | 1.8mm-24.0mm | |
6x19+FC,6X19+IWSC, 6X19+IWRC | 3.0mm-30.0mm | ||
6x19S+FC,6X19S+IWSC,6X19S+IWRC | 3.0mm-30.0mm | ||
6X19W+FC,6X19W+IWSC,6*19W+IWRC | 3.0mm-30.0mm | ||
6x12+7FC | 3.0mm-24.0mm | ||
6x15+7FC | 3.0mm-24.0mm | ||
6x24+7FC | 3.0mm-24.0mm | ||
6x37+FC,6X37+IWRC | 3.0mm-30.0mm | ||
Non-rotating wire rope | 18x7+FC,19x7 | 3.0mm-30.0mm | |
Elevator steel wire rope | 8x19S+FC,8X19S+IWRC | 3.0mm-24.0mm | |
Wire rope for crane | 6x25Fi,6x29Fi,6x31SW,6X36SW | 3.0mm-16.0mm | |
Wire rope for suspended platform | 4x19S+FC,4X25Fi+FC,4X26+FC,4X31S+FC 4X36WS+FC,4X41WS+FC | 3.0mm-30.0mm | |
Surface: Electric Galvanized, Hot dip galvanized,Ungalvanized,Ungalvanized with grease,PVC coated | |||
Tensile strength: 1570Mpa,1620Mpa,1670Mpa,1770Mpa,1960Mpa | |||
Material: high carbon steel rod | |||
Strandard: ASTM,GB,DIN,JIS,AISI,BS | |||
Brand:Zhengyang | |||
Term of payment: L/C, T/T, D/P, Western Union, One Touch | |||
Packing: 2000m roll,1000m roll,500m roll, 300m roll,200m roll or as your requirements | |||
Roll Quality:Wooden roll,steel roll,plastic roll | |||
Shipment:Within 30 days after received the down payment or receive the L/C | |||
Port: Shanghai,Nantong | |||
1.Used in the upper plates of bridges | |||
2.As cable for special bridges and for the maintenance of briges | |||
3.In construction,used in concrete pillars and supports for the construction of buildings | |||
Application: | 4.Used as floor and roof reinforcement for sports stadiums | ||
5.Used in construction materials for PC panels, high pressure concrete water pipes,marine structures, | |||
6.Ordinary usage:Lifting,Drilling,Crane,Hoisting,Towers and Runways,Mine,Service,Vessel,FishingGeneral Engineering Purposes etc. |
- Q: I have 2 connectionswire and wireless,im only connected to my wire how do I open a connection to my wireless?
- Are you saying your COMPUTER has both Wired and Wireless ability? If your computer is wired, it won't use the wireless adapter it will use the most trusted connection which is wired. If you want to connect wirelessly, you have to unplug the wired connection or disable it. Otherwise they can both be active but the wireless will only kick in if the wired connection fails. If you are asking something else, please claify. Like you have both a wired ISP and a Wireless ISP etc.
- Q: Just moved into a new house and the basement is already wired for surround sound. The ends are two wires one silver one gold/brass wrapped together with plastic. Looks like they were cut at the ends. How difficult would it be to wore the speakers myself?
- The color coded wire will correspond to the connection of the positive and negative. You would connect the wire to the receiver, depending on the location of the speaker. Check the speaker that is already installed and see what color wire is going to what terminal on the speaker and match that connection to your receiver. Front speaker connected to the front speaker terminal of the receiver. Your receiver owners manual will also provide you with some direction. Hope this will help you out.
- Q: the fused ignition wire and illumination wire, i cant figure out where they go on a Dual stereo system model1225 Help. ( on a 1990 ranger )
- the ignition wire is going to be a yellow with a black stripe(car wire) and the instruction manual will tell you for the head unit illumination wire i just taped up since my head unit didnt require it =) like they say...if it turns on it dont need it
- Q: A street lamp weighs 200 N. It is supported by two wires that form an angle of 130° with each other. The tensions in the wires are equal.What is the tension in each wire supporting the street lamp?If the angle between the wires supporting the street lamp is reduced to 100°, what is the tension in each wire?
- Problem 1: If the tension in the two wires are equal, the angle they make with the horizontal must also be equal. Always remember that a horizontal line is a straight angle; hence, it has a measurement of 180°. Let's look for the angle the wires make with the horizontal. 130 + x + x = 180 130 + 2x = 180 2x = 180 - 130 2x = 50 (Divide both sides by 2) x = 25° Each wire makes a 25° angle with the horizontal. We can now find the tension. The mass must be divided by 2. Using trigonometry, let's find the tension force. The divided weight of the lamp shall be the opposite side, and the tension force shall be the hypotenuse. sin 25° = (200 / 2) / Ftens Ftens = 100 / sin 25° Ftens = 236.62 N (Answer) The tension is 236.62 N in each wire. Problem 2: We use the same approach. 100 + x + x = 180 100 + 2x = 180 2x = 180 - 100 2x = 80 (Divide both sides by 2) x = 40° Each wire makes a 40° angle with the horizontal. Calculate the tension force. sin 40° = (200 / 2) / Ftens Ftens = 100 / sin 40° Ftens = 155.57 N (Answer) The tension is 155.57 N in each wire. Hope this helps!
- Q: Where would I get a 2001 wiring diagram for a Silverado chevy truck? I want to re-install the factory stereo that was taken out when I first got it? I have no idea what wire goes where. Thanks a lot.
- Car Radio Constant 12V+ Wire: Orange Car Radio Switched 12V+ Wire: Yellow Car Radio Ground Wire: Black Car Radio Illumination Wire: Gray Car Stereo Dimmer Wire: Brown Car Stereo Antenna Trigger: N/A Car Stereo Amp Trigger Wire: N/A Front Speakers Size: 6 1/2″ Front Speakers Location: Doors Left Front Speaker Positive Wire (+): Tan Left Front Speaker Negative Wire (-): Gray Right Front Speaker Positive Wire (+): Light Green Right Front Speaker Negative Wire (-): Dark Green Rear Speakers Size: 4″ x 6″ Rear Speakers Location: Side Pillar Left Rear Speaker Positive Wire (+): Brown Left Rear Speaker Negative Wire (-): Yellow Right Rear Speaker Positive Wire (+): Dark Blue Right Rear Speaker Negative Wire (-): Light Blue
- Q: I have noticed that a room in my house is improperly grounded, and it needs to be redone. We do know that most of the wiring is made with a single core, copper wire. Would there be a hazard with using a multi core (speaker) wire for the grounding, or should we do the wiring with a single core wire.
- No professional electrician would ever use speaker wire to wire a house.
- Q: I bought a new ceiling light and wired it myself. But I cheated by just copying the wiring from the old bracket into the new one. I want to do the other ceiling lights in my home. Supplied with the lights I am using is a 3 - way bracket (sori if terminology is wrong). Anyway the old bracket I copied was 4 way. My lights are wired from the mains supply with 3 live wires, 3 neutrals, and 3 positives. The light unit only has one live/neutral/positive wire. What do I do with the extra mains supply wires? I hope I have made myself clear as I even I am confused. Many thanks.
- One set of wires will be the mains feed the 2nd set will be the mains feed to the next light in the circuit and the 3rd set will be the switch wire. Copy like for like when changing them, taking care not to lose sight of the switch wire...
- Q: I understand that in a plug you have the earth wire, live wire and neutral wire. But what is the individual job of these wires?? I know how to wire a plug, i just want to know the individual job of each wire. This is not homework, this is something iam teaching myself.Thanks.
- The typical U.S. power distribution system has two hot wires coming into your electric panel, plus a neutral wire. The neutral wire is grounded to earth ground, as is the protective green earth wire. An outlet, carrying 110 volts from one of the hot wires (black), supplies current for the load and it flows back to the transformer on the pole normally via the neutral (white) wire to the center transformer (grounded) tap. The green protective wire does nothing in normal operation. However, should the appliance have a metal outer skin, and the machine develops a short, energizing the outer skin, it will flow through the green ground wire back to the transformer rather than through you and back to the transformer.
- Q: If 46 m of nichrome wire is to have a resistance of 12.0 Ω at 20°C, what diameter wire should be used? in mm
- Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Nichrome 150e-8 Ω-m 12 = (150e-8 Ω-m)(46m)/(πr?) solve for r, which would be the radius of the wire in meters. change to mm, and multiply by 2 to get diameter. .
- Q: Say you have a 5 cm current wire carrying 10 A going from left to right. Directly 1 c.m below the left end of this wire is a long wire that is perpendicular to the first wire and goes out of the page. What is the net force on the 5 cm wire?I've tried using F=ILB with the I of the first wire and the B of the second wire.
- I didn't read the question so I was carefully working out the force. The wire is perpendicular to the first wire, so using the right hand rule you discover that the field it creates is PARALLEL to the first wire at this left end. The magnetic force is caused by the component which is PERPENDICULAR to the wire which is in fact zero. So there is no magnetic force at this point. As you move along the wire you get a diminishing amount of magnetism caused by the wire which is going out of the page but that field has a component which is DOWN the page. Therefore that part of the wire experiences a force which is into the page. ( take your right hand, put the thumb along the wire pointing to the right, the fingers point down the page, the palm points into the page which is then the direction of the force) I would be surprised if you were required to work out the magnitude of the force in this context. You can't use F= ILB because both the magnitude and the direction of the field varies at different points along the wire. If the perpendicular wire had been directly below the middle of the other wire there would have been no net force. If you were of a level where working out the force was appropriate you would need to set up the formula for B at various points along the wire, taking the vertical component only and integrate this over the range from 0 to 5 cm. Not a trivial mathematical task.
Send your message to us
High Quality Galvanized Steel Wire Rope Sling For Bridge
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 100 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords