Galvanized Steel Channel Products
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Meters m
- Supply Capability:
- 30000 Tons per Year m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Common Size:
Size (mm) | Thickness (mm) | Material: - Pre-Galvanized - Hot Dipped Galvanized - Back to Back available
- spring nut, bolt, nut & washer are available |
27x15 | 1.2-3.0 | |
41x21 | 1.2-2.5 | |
41x41 | 1.2-2.5 |
Hole sizes:
10*25 / 14*28 / 11*25 / 10.5*30 / 12*35mm
Our Comnany:
Octopus Metal is specialized in support channel, galvanized steel coil distribution and cable tray manufacture.
We operate 2 large-scale factories with advanced equipments. Our product have passed SGS and CE certification.
- Q: It is best to be able to tell me the calculation method, be grateful
- You can go to the decoration shop to buy the power supply tube ... this is a safe and convenient tube. Gum you can use the brush to point the detergent or detergent to brush ... to ensure that your walls are shiny.
- Q: Where is the cable tray used? Fire power plant, coal mine group? For example, civil construction sites, some of the high-rise buildings.
- It is said that the two armored PVC control cables are 4x25 square, and the low-voltage cable wears the pipe along the ground. This logo does not seem clear. KVV22 should be armored control cable, then 4 * 25 before FC, can also be understood as four 25-diameter steel pipe.
- Q: What is the meaning of the bridge and the non-perforated tray on the electrical drawings?
- cable test: before making with 2500V megger measuring insulation resistance, generally should be greater than 5000MΩ
- Q: Steel cable bridge installation, how far a boom
- . indoor support, hanging short span generally take three, for the cable bridge support, hanger configuration 1.5-3m. Outside the vertical column in the vertical to take 6m. . non-straight section of the branch, hanger configuration to follow the following principles. When the width of the bridge is <300mm, a branch and a hanger shall be provided on the straight line side of the non-linear section and the straight line at 300-600m. When the width of the bridge> 300mm, in addition to meet the following conditions, in the middle of the non-linear section should also add a branch, hanger.
- Q: How the bridge slot is connected to the ladder
- And then press the picture in the picture to know the disappearance of the remote control on the marked in the remote control of the lower right corner or lower left corner
- Q: Renovation project, the cable bridge to pass through the fire shutter doors, but the actual situation at the top of the door beam can not open the hole, next to the bypass construction is very difficult, whether it can be in the rolling door below the ground to add a firewall, the equivalent of raising the fire shutter Floor. Then the bridge is laid along the ground through the newly added firewall. Is there any relevant specification for reference? More
- You people to raise the floor, where it becomes a slope or add a threshold to increase the resistance to escape, you think about it, can you? Tell you about this escape function: when the fire, the fire shutter doors will fall, but not all closed, down to half, stopped, so that people quickly escaped from the door, after a few minutes, Fire shutter doors continue to decline in the end, played a partition role
- Q: Cable bridge factory generally use what color, secondary anti-corrosion what color, what standard?
- If the owner does not specify the color of the bridge, and we can install the main color of the factory may be, usually using the box gray, of course, bridge accessories, arm, bracket and other auxiliary material color must match. Bridge coating matters and safety see the specification text according to the specification to install laying: GB1720 paint adhesion test -1979 paint adhesion test -1979.pdf "wealth =" 0 "& gt;
- Q: Seeking: cable tray 100cmx10cm bracket installation spacing requirements
- cable bridge and electrical equipment cross, the gap between the distance of not less than 0
- Q: What about it? Is such a good classmate, his father is the chairman of the construction company (surname), the total pro-brother's brother is the cable bridge and distribution cabinet, I said to the students, he said no Good to do, so close relatives. I would like to ask your colleagues how do you say, the total of these projects involving dozens of homes it? Help ~! The More
- Power cable where it does not matter, as long as there is a certain safe distance can be.
- Q: To ask the gods, with cad cable tray design, how to take into account the layers? Is a layer of a painting or a few layers together, how to set the specific color
- It is recommended to use YJV0.6 / 1kV3 * 240 + 1 * 120 cable, according to the data you provide to calculate the pressure drop, the use of this cable can limit the voltage drop of about 5%
1. Manufacturer Overview
Location | Tianjin,China |
Year Established | 2006 |
Annual Output Value | |
Main Markets | North America South America Southeast Asia Africa Mid East Eastern Asia South Asia |
Company Certifications | ISO14001:2004 ;ISO9001:2008 ;The SGS Certifications Of Cable Tray System |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Guangzhou,Shenzhen |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese, German, French |
b) Factory Information | |
Factory Size: | 50,000-100,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Average |
Send your message to us
Galvanized Steel Channel Products
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Meters m
- Supply Capability:
- 30000 Tons per Year m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches