Polymer cable tray customization Ladder type cable tray
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Introduction:
Ladder type cable tray has light weight, low cost, unique shape, convenient installation, good heat dissipation and air permeability. Its carrying capacity is better than trough type.
Parts:
Steel Lined、Cross Arm、Blocking 、Stainless screw、Holdfast、Anticorrosive and anti-aging protective coating
Application:
It is suitable for laying large diameter cables, such as basement, machine room, shaft, high and low voltage power cable laying.
Polymer material:
Polymer cable tray is a tray product of new materials. It is suitable for petroleum, chemical industry, textile, electric power, machinery, transportation, civil construction and other fields. It can replace the traditional metal tray at present.
Feature:
1.High polymer cable tray is made of high new polymer material PVC and ABS polystyrene oxygen, which has the advantages of strong heat resistance, low thermal expansion coefficient, good flame retardant, high insulation performance, strong corrosion resistance, long service life and so on.
2.The new alloy plastic cable tray can greatly meet the needs of customers by using only dozens of parts and components, greatly improving the flexibility and speediness of cable tray installation.
3.Improve the utilization rate of polymer materials, through verification than the conventional increase of about 5%.
4.The product has good appearance design and high decoration. It is made of plastic material, by injection molding and extrusion molding, and has good appearance design, which overcomes the disadvantages of poor appearance and low decorative performance of traditional products.
5.High polymer tray has long service life. Compared with the traditional steel tray, the service life is 5-8 times longer, which reduces the secondary input cost of replacing the tray. The corrosion resistance of traditional steel tray products is poor, and the tray must be coated and repaired regularly. The cost of materials and labor is high, and the corrosion resistance of polymer tray is strong, which greatly reduces the maintenance cost and maintenance time.
- Q: Due to the environment is not good, the original buried cable damage many times, want to use the bridge, but the overhead conditions are not allowed, the picture below is the hot water pipe, the above is the hot oil pipeline, but also over three doors more
- Because the balance is not good will cause serious consequences for non-standard remote control garage door, please be sure to seek the views of manufacturers; the installation of door balance system, please install the professional staff to carry out the installation of the staff, B) off at least 13m away from the ground, not let the children enough; C) Prohibited near the door of the moving parts; according to the instructions after the installation is completed; after the installation of the control button: A) must see the scope of the door; remote control open, close the garage door to see the door, do not let the children take the remote control; when the door to open the state, and to close the emergency need to be particularly careful to prevent the installation is not Good or spring failure and hit people; installation and wiring must be in accordance with building construction standards and electrical standards if possible, the drive installed in the ground above 21 meters above the place, the clutch should be taken from the ground should be 18 meters; the Hu provided by the provision of the power supply line on the ground lead; the installation of remote control garage door, are not allowed to wear rings, watches or wear loose clothes, the use of solid, the use of strong, Wooden ladder; the installation is complete, the manual hanging in the door, in order to regularly manual safety checks and maintenance Note: If your garage door does not have a side door, please be sure to install a power outage device, so that you can manually open the door from the outside when the power is turned on
- Q: Our drawings are messy, some cableway or walk the bridge it also wear steel pipe, I would like to have this need to explain, we this project is the highest 23 layers more
- It is to be installed and Ming Tu, not concealed and dark laying.
- Q: Shaft bridge 400 * 200 bracket should be how many meters a
- It should be cable terminal processing, they can be processed ah
- Q: What is the meaning of the bridge and the non-perforated tray on the electrical drawings?
- Your chassis is also supporting the back line, then the backplane threading hole reserved must also be reasonable and adequate
- Q: Cable tray elbow to know the angle and the width and height of the bridge how to calculate the problem of cutting more
- ZR is flame retardant, the general representative of the C-class flame retardant ZB is B-class flame retardant
- Q: In the bridge of the joints with a number of bolt cover fixed, there is a 20 cm long copper wire prepared by the flat, both ends were lap on the bolt. I do not know the role of this with the flat belt? Who knows, please enlighten me, thank you! More
- Resistance file can not measure the voltage, remember! Are generally measured with a voltage file to confirm the voltage can not be measured when the resistance, who said the resistance is small? gosh! , Measured voltage under normal circumstances are to have two points, you measured a wire, you can find another point, as upstairs said - water pipes, if not, you can hit the stall to the stalls , Directly with two pen on the wire to measure, but to keep a little distance! Instructions indicate that live
- Q: I am mainly doing street lighting project (including street-powered box-type substation installation), if any specific details of the other prizes, thank you! Question added: Please do my project sub-division, sub-items, inspection batch Tell, must re-thank more
- The national standards and industry standards for mining cables are as follows: GB / T
- Q: What is the difference between a fireproof bridge and a fireproof bridge?
- As if the fire bridge is fireproof, fire-resistant bridge is only a period of time fire resistance
- Q: What are the accessories that are connected to the bridge and what are the names?
- The first is a low-smoke halogen-free cloth wire, single-core only insulation without sheath, and the latter is a low-smoke halogen-free power cable, insulation is cross-linked polyethylene, jacket is low smoke
- Q: Seeking: cable tray 100cmx10cm bracket installation spacing requirements
- cable bridge and electrical equipment cross, the gap between the distance of not less than 0
Send your message to us
Polymer cable tray customization Ladder type cable tray
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords