• Deep Well Pump System 1
Deep Well Pump

Deep Well Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or L/C
Min Order Qty:
1 Set unit
Supply Capability:
1000 Sets Per Year unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
All the parts contacting with liquid are made of stainless steel 304 or 321 on request. Pump head and suction & discharge can be made of cast iron on request too.
Q: My water pump is losing pressure slowly even though no water is being used. Your help is appreciated. Thank you.
If the motor sounds louder than normal. Youll need to check the impeller in the pump. Make sure the shaft seal on the pump is not leaking. You either have a leak, restriction in the system or a bad impeller or failing pump motor.
Q: We have an electric sump pump. Battery pumps will only work for two or three days. I want a manual pump that will pump a lot of water. We cannot waterproof the basement because it costs over $10,000. Where can I find a manual pump? Carrying water out in buckets is too slow and exhausting. We carried 80 five gallon buckets out last time the electricity was off for a few hours.
There okorder ... They are typically installed as back up to the electric powered one and will only come on when the electric has failed. they use a siphon action that is supplied by water flowing through a pipe so they use a lot of water but as long as your house has water pressure they will keep the basement dry. When the electricity comes back on they shut off because their float switch is activated at a higher level that the electric ones.
Q: I have a 1969 Chrysler with a new 3 core radiator. It still has the stock water pump and I am wondering if a high volume pump would make it run cooler at higher speeds. It runs hotter when you get off the freeway. I have flushed the system and installed a new thermostat. I also replaced the fan clutch. I am at a loss of why it still runs warmer than the 180* thermostat.
High Volume Water Pump
Q: My water pump is sitting very close if not rubbing against the case. There were shavings and a groove. Would this cause it to knock? Also would this blow up the lower end? One more, Should it be in the center or offset twards the top?
Perhaps one of the shaft's retainers, the bearing, or gear is worn, allowing the water pump shaft to move in and out of the case - causing the impeller to rub on the outer cover. Try to pull the water pump out and push it in - there shouldn't be any play. If there is, figure out why. If the impeller can move in and out, that would cause it to knock. If there were any metal shavings in the coolant, they would scrape the outer cover. The water pump cover isn't an even shape, so I don't know what you mean by should it be in the center The bottom end and the cooling system are 2 separate entities. A problem with one will not affect the other.
Q: What will the water pump reversal situation?
The same will reverse pump water, but the head and the pressure greatly reduced, I just finished debugging a pumping station, Stephen multi-stage pump, installation of equipment: multistage water pump motor power 4 75KW 76% head 100 meters, frequency control, motor nameplate nominal current of 143. According to the direction of the motor steering pump mark OK set the start time of 28 seconds after 5HZ boot head start frequency can reach 50 meters (at that time did not install the pressure gauge cannot observe the water pressure of current) in early 118 about 3-5 minutes after the current is reduced to about 97, there are inspection found no problems, suspected pump problems, suspected foot valve not completely open, the reason cannot exclude the end of valve, almost in despair when the thought is not marked in the direction of the pump, re set to restart the current 129.5A to observe that later installed capacity reached 0.55MPa duct pressure gauge head close to the design requirements, the problem on the manufacturer's mark is reverse.
Q: how often do i need to change a timing belt and water pump on my car? also, how much should it cost? should i have it done at the dealers or at a small mechanic shop if i chose to? which would be best? what are steps when having timing belt change?
every 60000 miles do not go to the dealer they will charge u up the a s s and i dont know what kind of car u have most car i do i get $ 175 $ 275 make sure u change the watwe pump at the same time
Q: We use this water pump for about 2 years, and in the last week the circuit breaker trip when we turn on the pump. What should I check first for the problem?
When the pump motor starts, it engages a start winding that can draw enough current tripping the breaker in question. I would recommend that you change the breaker. It may have become weak after years of operation of said pump. It is a very good idea to dedicate a breaker for this motor. This configuration will insure that there's not another appliance in the circuit that may cause this problem of overloading said breaker when a limit switch closes to turn on the pump. Feel free to e-me.
Q: Okay, I'm setting up an NFT hydroponic garden and am now looking for the water pump. I would like some suggestions for one that will give a steady stream at a good rate for the plants. But, it must have a minimum lift of 5ft to reach the first level.I would prefer one with a flow rate adjustment but if you could at least make a suggestion to the GPH it should pump for the right flow after a 5 ft climb I could search more in that range for one I like.Thank you!
I think you may want to look at the small pond pumps and just about any nursery or home supply store or landscaping store. they may have the specs on hand, or see if they can demo one for you. some places have a display pond set up already. You also might try a small swimming pool pump and put a voltage regulator in the line and adjust the pump speed that way. maybe rig a sewing machine pedal in the line and use a C clamp for an adjuster. I love rigging thing. It may not work with a gfi plug.
Q: My house uses a pump that draws well water. With a family of four, I had never had a problem running out of water, even through 4 morning showers. Recently however, I have started running low and sometimes even run dry of water, although it’s now just me and my wife living at home. The pump is only a couple of years old. A couple of neighbors also have wells and pumps, so I don’t believe the water shelf has run low. The holding tank is at least 15 years old and probably older. I don’t know if it has a bladder, but I think it does. It’s a Wel-Trol brand. I’ve checked the pressure with a tire gauge and it holds at 30 psi. Also, it seems the cut in and out switch has a mind of its own. It especially would continue to run, even though the pressure hit cut-off level. Any ideas or suggestions?Thanks
Hmmmmm. I think I would look at the pressure switch here if you can confirm that the well does have adequate water in it. The next thing is the small pipe that the pressure switch mounts on. If it is galvanized these have a tendancy over the years to build up deposits and rusty scale and may need to be replaced. It sounds like you have the bladder style of pressure tank and that is a good thing. To check the proper pressure in the bladder watch to see the cut off pressure of the pump as it cycles. Note this. Turn the pump off and completely drain off the pressure tank. Check and adjust the pressure at the top of the Wel-Trol to be 2 to 4 pounds less than the pressure cutoff that you noted using compressed air. As the other posts have mentioned you also may have a leak in the pressure line to your house. The way to test this is turn off all the water to the house and see if there is a check valve in the T at the pressure tank. It will look like a tube about 2 inches in diameter and 4 inches long. Usually there is not one here as they clack when the pump shuts off. If there is not one note the pressure. See if it drops. There should be no drop. If it is a drilled well there may be a leak in the pipe down the well and this usually requires a visit from a well servicing company to determine. Hope this helps.
Q: Horizontal pumps, vertical pumps, which kind of expensive?
Not expensive, depending on the specific model, in fact, the vertical pump is not much
Our main products are all kinds of centrifugal pumps, displacement pumps and vacuum pumps, such as oil pumps, multi-phase pumps, single stage and double suction centrifugal pumps, horizontal split case pumps, multistage pumps, axial-flow pumps, mixed flow pumps, petrochemical pump and submersible pumps. Besides, our company also manufactures electric motors and sells electric motors, building materials, indoor decoration materials, civil electric equipment, devices and instrumentation, as well as exports our mechanical and electric products.

1. Manufacturer Overview

Location Hunan,China
Year Established 2006
Annual Output Value US$5 Million - US$10 Million
Main Markets 59.00% Mid East
8.00% North America
8.00% Southern Europe
5.00% Eastern Asia
2.00% Africa
2.00% Oceania
2.00% Southeast Asia
2.00% Western Europe
2.00% South America
2.00% Central America
2.00% Northern Europe
2.00% Eastern Europe
2.00% South Asia
2.00% Domestic Market
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port SHANGHAI,GUANGZHOU,DALIAN
Export Percentage 51% - 60%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: Above 100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords