• Copper Conductor Armoured Underground Cable System 1
  • Copper Conductor Armoured Underground Cable System 2
  • Copper Conductor Armoured Underground Cable System 3
  • Copper Conductor Armoured Underground Cable System 4
  • Copper Conductor Armoured Underground Cable System 5
  • Copper Conductor Armoured Underground Cable System 6
Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
50000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

Copper Conductor Armoured Underground Cable

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Q:all of my wiring seems okay and everything seems to work except for my amp power. I have the blue cord on the harness wired into the blue/white cord in my kenwood because i tried going blue to blue and it didnt work. So i have the remote cable from my amp plugged into the blue cord on my head unit. I have no power to my amp.
Kenwood Kdc-mp245
Q:Hello guyzz, recently i have bought new card powercolor radeon hd 6770 1gb gddr5 .i installed it but it required a 6 pin power cable forbut i checked in my all pc.i cant fine any 6 pin power cable.so without any cable its not working wat i do plzzz help.
Buy okorder
Q:I need help asap before I lose my patience with my dog.
Try Radio Shack or if it has a 3 prong socket any computer power cable will work.
Q:I have a feeling my power quot;brickis faulty and need to find a replacement, hopwever, none of the high street retailers quot;Game, Gamestation, HMV, Argosseem to stock them.
u can contact microsoft talk to them on teh phone for 5-10mins and theyll giv u a free one
Q:I have a two year old HP Compaq 6710s laptop, and since yesterday, the second I plug in my power cable, my CPU usage goes up from a normal amount to 100% immediately, making my computer really really slow. Is there anything I can do to fix this? Do you think there's something wrong with the cable or the computer?
i wouldn't of thought that would of been a problem charging, have you tried different sockets around the house ? that's all i can think of at the moment
Q:is there any way to fix this? i don't want to upgrade my power thingy though.
just buy the long cable...easy right?
Q:I have a Netgear router and just now when I tried to plug the power cable back into the back of it, it would fit. I look more closely and it seems that the metal end of the power cable may be slightly bent. But I'm still confused because it's bent at the end of the metal, and even though the very tip of it isn't bent, that part still won't even slide into place a little. Could anyone help me in resolving this issue?
If it is the correct adapter for the router and it fitted before, gently force it and it will comfortably fit eventually. There is probably a reason it doesn't fit now (it has been pulled out with some force) so I would suggest getting a new power adapter for it if the above does not work
Q:i bought a car from some guy..he had 2 amps but he took out one...he had the power cable running from one amp to the other. i just recently bought another amp and i was wondering if its safe to do this.he said it was working fine..he was powering 2 10 subwoofers..thats what im planning to do
it is safe...but not the best method it really depends on the guage of the wire....best to have a single large gauge running to a distribution block then a wire for each amp comming out of the block to were the amps are. blocks are fairly cheap (usually less than 20 bucks) and safer...plus you get better power flow and 1 amp is not sucking all the power before it gets to the other
Q:How long is the service life of the cable?
cable bridge and other pipes and other facilities shall not share a column (bracket)
Q:I've heard of a new file transferring tool which transfers file through power cables and I need to know about how it worksand how does it apply the pulses or the waves to the frequency of the power cables!!
No it is not possible to transfer the data through power cables, Ask what you actually want to do i will solve your problem.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches