• Underground Cable Steel Wire/type Armoured Copper Power cable System 1
  • Underground Cable Steel Wire/type Armoured Copper Power cable System 2
  • Underground Cable Steel Wire/type Armoured Copper Power cable System 3
Underground Cable Steel Wire/type Armoured Copper Power cable

Underground Cable Steel Wire/type Armoured Copper Power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.Professional supplier 
2.Reliable quality,best price 
3.Strong capacity,fast delivery 
4.PVC or XLPE insulated power cable

1.  Products applications:

 

PVC insulated Power cables are fit for A.C rated voltages 600/1000V power transmission and distribution system.

 

2. Products standard:IEC 60502

 

3. Products characteristics:

 

--Long-term maximum working temperature of conductor should not be higher than 70°C, laying temperature should not be lower than 0 °C.

--Once short-circuit (the Max. duration 5s), the maximum conductor temperature does not be over 160 °C.

--Laying bending radius: Single-core and armored cables laying bending radius should not be less than 20 times of cable’s outer diameter value, however, multi-cores unarmored/armored cables laying bending radius should not be less than 15 times of cable’s outer diameter value.

 

 

4. Products types and names:

 

Cu

Al

Names

Cu/PVC/PVC

Al/PVC/PVC

PVC insulated and sheathed power cables

Cu/PVC/AlTA/PVC

Al/PVC/AlTA/PVC

PVC insulated and sheathed power cables with Aluminum tape armored

Cu/PVC/AlWA/PVC

Al/PVC/AlWA/PVC

PVC insulated and sheathed power cables with Aluminum wires armored

Cu/PVC/SWA/PVC

Al/PVC/SWA/PVC

PVC insulated and sheathed power cables with Steel wires armored

 

 

5. Cable properties and use instructions:

 

--For unarmored cable, is suitable for laying in indoors, cable channel and conduit etc., such cables can’t bear strong mechanical force.

--For STA armored cable, is suitable for underground installation , which can withstand certain mechanical pressure,but can’t withstand mechanical tension,on the contrary, for SWA armored cable, is suitable for vertical installation, which can withstand certain mechanical tension, but can’t withstand mechanical pressure.

--For PVC sheath not only has excellent chemical corrosion resistance, but also has the properties of flame retardant and non water-absorption.

-- For single-core armored cables, non-magnetic material or Aluminum tape is main armored material, which only applies to D.C system.


Q: My 4 pin CPU power cable is too short can I plug the 6 pin cable into that 4 pin slot? Safely? Thanks in advance for your help.
No, okorder . I know they have extensions so they should have what you are looking for.
Q: I purchased a LCD TV the other day and ran a cable line to it (via crawl space). I had to use a splitter to connect the new TV. I connected the cable directly to the TV and then the power cable to the outlet which “popped” and the power went out (breaker trips). I connect the TV power cable to a surge protector and the power goes out again (surge protector wasn’t even on). So I disconnect the cable from the tv and connect the power. Everything is fine until I try and connect the cable...let’s just say the spark was bright and hot enough to melt part of the connector on the TV! So I return the TV and get a different brand and the same thing happens when I plug it into a surge protector. To begin narrowing out possible problems I connect the cable to a regular 10 year old TV with no problems. It is a brand new cable with no cuts or fraying. Any suggestions?
Something is seriously wrong, and you may need to get an electrician on the problem. You need to check the voltage between your set and the cable with a meter. There should be little or no measurable voltage. If you are getting a reading like 115 volts, then I suspect that the wall outlet into which your TV is plugged has been wired backwards, i.e. the black wire is on the white terminal, and vice-versa. The cable is (or should be) grounded where it comes into the house, but if the outlet has the hot wire on the wrong side, this might cause the problem you described. The wrong connection could have occurred anywhere along the line between your main panel and the outlet, so this may involve checking the connections at several outlets and light fixtures - whatever is on the same circuit as your TV's outlet.
Q: How to choose the diameter of the power cable threading protection tube?
If you are using a cable that is suitable for direct burial, you do not need a casing. But in the place into the building, should be casing, in order to protect. General steel pipe can be.
Q: Can A bad battery or power cable cause a laptop to Blue Screen?Is there anyway to pinpoint the actual cause?
No its usually because of hard drive failure if your talking about THE BLUE SCREEN OF DEATH
Q: high effency double shielded transmission power cable?
What is your question? Does such a cable exist? Probably but you'll have to be more specific. High efficiency = low loss or low resistance per foot? Double shielded = is the shielding (in dB) critical? Transmission = What frequency, 60 Hz, 1 MHz, 100 MHz, ? Power = Watts, KW, MW Is weight or cost important?
Q: Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q: power cables of 630 mm buried (cable trench) what could be the reason for fire?
A very high power surgeon could cause it. Very high current transfer of a short circuit could cause burning of the cable. Power cables have materials which have very high resistance (rubber materials mostly) but could burn in a not very high temperature.
Q: I need help asap before I lose my patience with my dog.
Try Radio Shack or if it has a 3 prong socket any computer power cable will work.
Q: When I unplug the power cord from my laptop the screen brightness automatically dims down to about 10% of its total brightness, and when I click the quot;increase screen brightnesskey on the keyboard the brightness will only increase about 5% until it stops. It's like I've put some limit as to how bright the screen can get. Anyone know how to fix this?
This is standard on laptops. The display takes a lot of power so it is set to dim when there is no mains power. You can go to Control Panel, Power Options and change this. You will need to tell it that this isn't a laptop.
Q: How many amphs does the us ps3 slim's power cable have? It should be #A?
i don't know why youre trying to find this out but heres a chart. The power cable has different electricity usages depending on what youre doing but the average is 87 ish

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords