1. Performance of CDL Series Stainless Steel Vertical Multistage Pump
Flow Range:1-200m3/h
Head Range:11-200m
Power Range:0.37-110KW
Temperature:-20ºC-120ºC
Material:Stainless Steel 304,316
Work Pressure:<1.6mpa< span="">
2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor).
3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber.
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC
Environmental temperature: highest + 40 ºC
Height: highest 1000m
4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors.
Protection grade: IP55
Insulation grade: F
Standard voltage: 1Ph 220-230/240V
3Ph 200-220/346-380V
3Ph 220-240/380-415V
3Ph 380-415V
5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization.
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system.
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator.
Irrigation: farm irrigation, sprinkler, drip.
6. FAQ
1> Can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
2> Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
3> How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.
- Q: What is the minimum continuous flow of a pump?
- Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: Why should I pump the pump before starting the centrifugal pump?
- 1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
- Q: What is the difference between centrifugal pump and positive displacement pump?
- Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- 3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
- Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- (three) infusion limited number of pills produced after the dose of obstruction by infusion pump and specification of the matching test, will reach acceptable when the storage pressure of the pressure to determine the alarm blocking. Thus, some have restrictions on the infusion tube blocked after the maximum dose pill may have blocked the trigger before the alarm.
- Q: How many pumps does the 80cm tank use?
- Mainly look at the flow of the pump, all pumps have flow signs, such as 15L/HThe above is I at random, meaning that 15 litres per hour. You should calculate the volume of your cylinder, that is, the length of the tank, the width and the height of the water surface, the unit is cm. The result is 1000, which is the volume of your fish tank
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
- Q: Which nuclear submarines use the shaftless pump technology?
- The team led by academician Ma Weiming of China is now carrying out the research on this technology and has achieved initial success.. This technology is expected to be applied to the next generation of domestic submarines.
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Send your message to us
CDL Series Stainless Steel Vertical Multistage Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords