• CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump System 1
  • CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump System 2
  • CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump System 3
CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump

CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Performance of CDL Series Stainless Steel Vertical Multistage Pump

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.


CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump

CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump





Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Looking forAlignment means the position of the center of rotation of the pump and motor so that they are in the same line.At least three times after the initial installation or after installation:
Q: What are the general water pump failure, how to repair?
(2) in contact with the water pump inlet of the horizontal application of reverse flow direction, fell more than 0.5% slope, connect one end of the highest import pumps, do not completely level. If the upward tilt, the intake pipe will retain air, reducing the water pipes and pumps in the vacuum, water absorption.
Q: What is the Rhodes pump?
Best answerRoots vacuum pump (referred to as: Roots pump) refers to the pump is equipped with two opposite direction of synchronous rotation of the leaf rotor, rotor, rotor and pump housing between the walls of a small gap and no contact with a variable capacity vacuum pump.Roots vacuum pumps have been tested for long time in the fields of petroleum, chemical, plastic, pesticide, steam turbine rotor dynamic balance and aerospace simulation, so it should be popularized and applied in china. It is also widely used in petroleum, chemical, metallurgical, textile and other industries. Vacuum pump fittings are used for noise control of vacuum pumps, vacuum pump silencers.
Q: Is the sewage pump the same as the mud pump?
The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
Q: Is the centrifugal pump large or small?
NPSH is also called cavitation, cavitation is too big to be.3, pump the liquid when working in the impeller inlet will produce vapor due to a certain vacuum pressure, vaporization of the air bubbles in the liquid particle movement under the impact of erosion on the impeller, the metal surface, thus undermining the impeller and other metal, then vacuum pressure is called vaporization pressure, NPSH is excess vaporization pressure of surplus the energy position of the unit weight of the liquid in the pump suction port of. The unit with annotation, (NPSH) r with. The absorption process is necessary NPSH H: pump suction fluid allows the vacuum pump installation height is allowed, in meters.
Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
7., master the knowledge of concrete mix ratio, strictly forbid to add water to the pump at will.8., concrete mixing and workability, gravel diameter is too large, effectively refuse to pump.9. when the delivery pump fails, it can analyze the cause and quickly eliminate the trouble.10. pump complete, you must clean the pump body and pressure pipe residual.11. complete other temporary work assigned by the leader.
Q: Harm of air pump and pump
Centrifugal pump situationEmpty pump is divided into two kinds, if there is no liquid, then it will cause the mechanical seal of the pump to overheat, wear and even die
Q: What are the parts of a pump? How do you classify it?I just want to know
Before opening the pump suction pipes and pumps must be filled with water. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet. The outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuous outflow from the discharge pipe.Mainly by the impeller, pump shell, pump shaft, bearings and packing sealing devices and other components
Q: Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q: What do you mean by the self coupling device on the pump?
Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords