CDL Stainless Steel Vertical Multistage Centrifugal Water Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Performance of CDL Series Stainless Steel Vertical Multistage Pump
Flow Range:1-200m3/h
Head Range:11-200m
Power Range:0.37-110KW
Temperature:-20ºC-120ºC
Material:Stainless Steel 304,316
Work Pressure:<1.6mpa< span="">
2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor).
3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber.
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC
Environmental temperature: highest + 40 ºC
Height: highest 1000m
4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors.
Protection grade: IP55
Insulation grade: F
Standard voltage: 1Ph 220-230/240V
3Ph 200-220/346-380V
3Ph 220-240/380-415V
3Ph 380-415V
5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization.
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system.
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator.
Irrigation: farm irrigation, sprinkler, drip.
6. FAQ
1> Can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
2> Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
3> How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.
- Q:What is a water pump coupling device?
- Advantages of water pump coupling device:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device, fixed installation, such as water pump failure, maintenance personnel need to unscrew screws, lifting pumps for maintenance, or with other small pumps pumping water perfect maintenance,If the water is dirty, it is difficult for people to get down, when the inspection and repair encountered great difficulties. But it is equipped with GAK submersible sewage pumpAfter the automatic coupling device needs lifting, the person can directly lift the water pump without the need to screw the screw into the waterAfter graduation, down the guide rail, you can realize the sealing of water pump and pipeline, so as to make the pump run normally. Small sewage pumps are freeInstallation, large sewage pumps are generally equipped with automatic coupling device, automatic installation, installation and maintenance is very convenient.
- Q:Why can't the inlet of centrifugal pump be negative pressure?
- Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
- Q:What is the distance between the pump and the wall?
- What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
- Q:Why does the centrifugal pump close the pressure to start?
- The flow is zero (i.e. off dead) minimum, the highest lift power; with the outlet valve opening increases, flow increases, the lift, power and efficiency are increased, the maximum value (usually in the vicinity of the highest rated flow point)
- Q:Pump unloading in hydraulic transmission,
- Unloading is pumping oil directly back to the tank, the pressure is very low, energy saving
- Q:How to install, operate and maintain the pipeline booster pump?
- When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
- Q:Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 7., master the knowledge of concrete mix ratio, strictly forbid to add water to the pump at will.8., concrete mixing and workability, gravel diameter is too large, effectively refuse to pump.9. when the delivery pump fails, it can analyze the cause and quickly eliminate the trouble.10. pump complete, you must clean the pump body and pressure pipe residual.11. complete other temporary work assigned by the leader.
- Q:The main factors affecting the performance of centrifugal pumps
- The low specific speed pump, on the other hand, is suitable for smaller flow and higher lift. When the pump outlet pipe diameter at the same time, if the two pumps flow similar, smaller than the speed of small head, shaft power consumption is also large. Generally speaking, the centrifugal pump with smaller revolutions than the impeller has a narrow outlet width and a large outer diameter, and the channel formed by the blade is narrow and long. If the ratio of revolutions is large, the impeller outlet is wide and the outer diameter is small, then the flow passage is short and wide.I hope my answer will be helpful to you. I hope to adopt it!
- Q:What flowmeter is installed after the pneumatic diaphragm pump?
- According to your entire pipeline system to flow meter ah!How about the pressure, the material, the digital float or what?You must be sure of the size of the flow
- Q:What are the general water pump failure, how to repair?
- (4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
CDL Stainless Steel Vertical Multistage Centrifugal Water Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords