CDL/CDLF(T) Series Stainless Steel Vertical Multistage Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Performance of CDL Series Stainless Steel Vertical Multistage Pump
Flow Range:1-200m3/h
Head Range:11-200m
Power Range:0.37-110KW
Temperature:-20ºC-120ºC
Material:Stainless Steel 304,316
Work Pressure:<1.6mpa< span="">
2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor).
3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber.
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC
Environmental temperature: highest + 40 ºC
Height: highest 1000m
4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors.
Protection grade: IP55
Insulation grade: F
Standard voltage: 1Ph 220-230/240V
3Ph 200-220/346-380V
3Ph 220-240/380-415V
3Ph 380-415V
5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization.
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system.
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator.
Irrigation: farm irrigation, sprinkler, drip.
6. FAQ
1> Can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
2> Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
3> How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.
- Q:How to adjust the flow of piston pump?
- Changing the size of the current in the solenoid valve can change the angle of the tilting element, and then change the stroke length of the plunger in the pump cylinder, that is to say, to change the flow of the pump. An inclined angle is called a quantitative pump, and the angle of inclination can be changed, which is called a variable pump.
- Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- Each impeller is of the first stage. (two impellers share only one level, and exit is only level one)
- Q:What is the lift of diaphragm pump?
- Tell you: diaphragm pump head is liquid through the pump energy obtained is called lift it, and flow and pump speed, a liquid density is generally 1 kg is 10 meters lift, horizontal pipeline 10 meters 1 meters lift, a 90 degree bend is 1 meters.
- Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
- [pump voltage] when braking, in the motor winding series resistance, motor equivalent to the generator, the energy will be converted to electric energy consumption in the series resistance. This method is widely used in all kinds of motor braking, and frequency conversion control is also used. From high to low (zero speed), then the electrical frequency changes quickly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power,
- Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
- Q:What is the cause of the damage of pump bearings?
- First of all, know your pump model, and what is the bad bearing, in order to accurately judge for you. Because in addition to some common reasons, the structure of different pumps, bearing damage caused by the reasons are different. Otherwise it is fraught with itching shoes.
- Q:Variable flow pumps are variable pumps
- Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
- Q:Water pump outlet valve sequence
- To reduce the impact of vibration, noise and vibration on the valve, the soft connection is best at the pump outlet.The check valve is sometimes checked, so it is placed in front of the outlet valve so that the water can be checked out. I think the order should be: pump outlet, soft connection, check valve, gate valve (butterfly valve)
- Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
- As the name suggests, centrifuges are machines that achieve centrifugal effects by centrifugal action. And you say the centrifugal pump is only specific, and the same as the pump
- Q:How many kinds of pumps are available and the operating principles of various pumps?
- There are many kinds. See what divides.According to the working principle can be divided into: the power type pump, also called pump or impeller vane pump, depending on the dynamic effect of the rotation of the impeller on the liquid, the continuous energy transfer to the liquid, the liquid kinetic energy (mainly) and the pressure will increase, then converting kinetic energy into pressure energy through the discharge chamber, and can be divided into centrifugal pump, axial flow pump, partial flow pump and vortex pump etc..
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
CDL/CDLF(T) Series Stainless Steel Vertical Multistage Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month