1. Performance of CDL Series Stainless Steel Vertical Multistage Pump

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

 

CDL/CDLF(T) Series Stainless Steel Vertical Multistage Water Pump

CDL/CDLF(T) Series Stainless Steel Vertical Multistage Water Pump


Q: Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q: What is a solution pump?
2.1 advantages of canned pumps(1) fully enclosed. There is no dynamic seal in the structure. Only the static seal in the outer shell of the pump can be made without leakage. It is especially suitable for transporting flammable, explosive, precious liquids and toxic, corrosive and radioactive liquids(2) high safety. The rotor and stator each have a shielding sleeve, so that the rotor and stator of the motor are not in contact with the material, even if the shield is broken, it will not produce the risk of leakage and leakage(3) compact structure and small footprint, the pump and motor is a whole, disassembly and assembly do not need to find the center. The base and foundation requirements are low, and the daily maintenance workload is low, and the maintenance cost is low
Q: Advantages and disadvantages of centrifugal pumps?
The centrifugal pump has no valve, so it is suitable for conveying suspended liquid, and the special design can also transport large solid suspensionThe pump can be made of chemical resistant material, which is suitable for conveying corrosive solution.The utility model has the advantages of simple structure, few parts, little failures, durability, low maintenance cost, convenient management and reliable work.The output can be adjusted even by the discharge valve fully closed, there is no danger of infinite rising pressure head.The liquid is transferred to a large quantity. And the pressure head does not require large, most suitable for centrifugal pump.
Q: There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
The ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and rotor drive. The structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so the utility model can be completely free from leakage.
Q: What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Displacement of a pump: the volume of the discharged liquid calculated by the change in the size of the sealing geometry for each revolution of the hydraulic pump
Q: What is the difference between centrifugal pump and rotary vane pump? What are the distinctive characteristics or principles of rotary and centrifugal? O (a _ U) O thank you!
Directly said vane pump on the line, generally do not say rotary vane pump.The centrifugal pump is divided according to the direction of the liquid flow in the impeller
Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
The front stage pump to a certain pressure to start the roots pump, roots pump has advantages of is at the entrance of low pressure gas pumping speed is high, popular point is in high vacuum pumping speed is still relatively large. With the former pump can achieve different limit the vacuum is different.
Q: What should be used to pay attention to the use of mechanical pumps?
When opening the pump, first close the outlet valve, lift the pressure, then open the outlet valve again, pay attention to the flow of the motor.

Send your message to us