Binding Iron Wire Black Annealed Iron Wire 16g with High Quality
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 25000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Binding Iron Wire Black Annealed Iron Wire 16g with High Quality Description:
Black Annealed Iron Wire also called galvanized steel wire, galvanized iron wire according to the difference zinc coating process, there are electro galvanized iron wire and hot-dipped galvanized iron wire.
Black Annealed Iron Wire can be classified into hot-dipped galvanized iron wire and electro galvanized wire according to the differences of processing. This wire is very good for Chain link fence, fencing mesh, gabion mesh box production and for construction business as tire wire, binding wire and galvanized wire raw material production.
2.Main Features of Black Annealed Iron Wire:
• Use widely
• Corrosion- resistant
• Durable
• Practical use
• Beauty Surface
3.Black Annealed Iron Wire Images
4.Black Annealed Iron Wire Specification
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your products?
We are focus on steel wire trading for more than ten years. We are specialized in export of various kinds of steel wire and wire mesh products, like Black Annealed Iron Wire we offer high quality steel wire; hot dipped wire; electro galvanized wire; PVC /PE coated wire; fencing , steel wire rope, steel wire strand, cable wire; wire mesh and other wire related products.
②What is the advantage of our Black Annealed Iron Wire?
1. Durable service life and competitive price.
2. Beautiful, strong and not expensive.
3. With long live and good anti-corrosive
4. High quality and low price.
③How long can we receive the product after purchase?
In the purchase of Black Annealed Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.
- Q: Please help, I'm stuck on this problem:An aluminum wire and a steel wire, each of length 4m, are hung from the ceiling. A 7 kg mass is suspended from the lower end of each wire. The aluminum wire has a diameter of 1.1 mm. What must be the diameter of the steel wire if it is to stretch the same distance as the aluminum wire, so that the two wires maintain equal lengths after masses are attached? Young's modulus for aluminum is .70 x 10^11 Pa and for steel it is 2.0 x 10^11 Pa.
- With the usual symbols E= FL/eA, so F = EeA/L Call the aluminium wire '1' and the steel wire '2'. The tensions are the same (weight of 7kg) so: E?e?A?/L? = E?e?A?/L? Since the extensions and lengths are the same e?=e? and L? = L? so these cancel: E?A? = E?A? A?/A? = E?/E? Let the diameter of the aluminum wire be d? mm. Since the cross-sectional areas are proportional to the diametera squared: d??/d?? = E?/E? d? = 1.1 x √(0.70/2.0) = 0.65mm
- Q: I have 16 gauge speaker wire, but i need a lower gauge. instead of spending money and buying a lower gauge can i double this wire up and have that make it a lower gauge? so i would have 2 negative and 2 positive wires going into the terminal.
- Doubling the wire will not make it 8 gauge. If you're running this wire from the head unit to the speakers, or from an amp to the speakers, 16g will be sufficient. If the wire is from an amp to a sub, a larger wire would be a good idea, but not a requirement. If you're trying to use this wire for the power and ground connections on the amp, you should purchase the proper wiring kit for amp installation.
- Q: I am moving a stove that has four wires - bare copper (ground), red, white, and black.The location I am putting it in only has three wires - red, white, and black.Can I just ignore the ground on the new location since it doesn't have one? Or should I cross one of the other wires with the ground?
- Your four-wire stove has a terminal where you can connect the bare/green and white wires together, most have a jumper to connect the two terminals. You don't want to leave any wires unconnected. The other two wires (red black) are connected the same way between 3-wire and 4-wire units. You'll have to buy a 3-wire cable for your stove to plug it into the 3-wire receptacle. The new code requires 4-wire connections. The bare/green wire and the white neutral wire are run back to the circuit breaker panel separately at which point the are connected together on a buss bar.
- Q: 01 F350 that did not come factory with cab lights.Bought the recon cab lights that come with its own harness. No plugs on the ends, just plain wires on the end. Where does the green wire splice in to behind the passenger kick panel?
- If okorder it will give you a complete wiring diagram of you entire truck.
- Q: A street lamp weighs 200 N. It is supported by two wires that form an angle of 130° with each other. The tensions in the wires are equal.What is the tension in each wire supporting the street lamp?If the angle between the wires supporting the street lamp is reduced to 100°, what is the tension in each wire?
- Problem 1: If the tension in the two wires are equal, the angle they make with the horizontal must also be equal. Always remember that a horizontal line is a straight angle; hence, it has a measurement of 180°. Let's look for the angle the wires make with the horizontal. 130 + x + x = 180 130 + 2x = 180 2x = 180 - 130 2x = 50 (Divide both sides by 2) x = 25° Each wire makes a 25° angle with the horizontal. We can now find the tension. The mass must be divided by 2. Using trigonometry, let's find the tension force. The divided weight of the lamp shall be the opposite side, and the tension force shall be the hypotenuse. sin 25° = (200 / 2) / Ftens Ftens = 100 / sin 25° Ftens = 236.62 N (Answer) The tension is 236.62 N in each wire. Problem 2: We use the same approach. 100 + x + x = 180 100 + 2x = 180 2x = 180 - 100 2x = 80 (Divide both sides by 2) x = 40° Each wire makes a 40° angle with the horizontal. Calculate the tension force. sin 40° = (200 / 2) / Ftens Ftens = 100 / sin 40° Ftens = 155.57 N (Answer) The tension is 155.57 N in each wire. Hope this helps!
- Q: Some states allow the use of aluminum wire in houses in place of copper. If you wanted the resistance of your aluminum wire to be the same as that of copper, would the aluminum wire have to have a greater diameter than, smaller diameter than, of the same diameter as the copper wire? Calculate the thickness ratio of aluminum to that of copper.
- The resistivity of copper is ρ_Cu = 1.72 x 10^(-8) ohm - meters, whereas that of aluminum is ρ_Al = 2.82 x 10^(-8) ohm-meters [1]. Assuming that the wire runs are the same length L, the resistance in the aluminum wire will be R_Al = ρ_Al * L/A_Al, where A_Al is the cross-sectional area of the aluminum wire. The resistance in the copper wire will be R_Cu = ρ_Cu * L/A_Cu. If we want the same resistance in both wires, we require R_Cu = R_Al: ρ_Cu * L / A_Cu = ρ_Al * L / A_Al A_Al / A_Cu = ρ_Al / ρ_Cu. Since the resistivity ρ_Al of aluminum is higher, the aluminum wire must have a larger cross sectional area to yield the same resistance. To make this precise, suppose the wires are cylindrical. Then the cross sectional area is π(R_Al)? for the aluminum wire and π(ρ_Cu)? for the copper wire: π(R_Al)?/π(ρ_Cu)? = ρ_Al / ρ_Cu R_Al/R_Cu = √(ρ_Al / ρ_Cu) = √(2.82/1.72) = 1.28 The aluminum wire must be 28% thicker than the copper wire in order to provide the same resistance.
- Q: Me and a buddy took the 305 out of the car. I have a 350 to take its place, but was wondering what are the only wires i need to have a clean engine bay. the old engine has a million wires hooking up to everything. Some muscle cars only have spark plug wires, the starter wire and battery cable. What must i do to get mine like that? i dont care about emissions. what must i change or add to the new engine?
- I have an '84 Monte SS and wanted the same thing. Here's what I have: the 2 wires that come from the harness and go to the starter (1 Positive, 1 S terminal), oil gauge wire, temp gauge wire, the alternator wires, the wire going to the distributor cap, and the tach gauge wire going to the distributor cap. That's pretty much it, as well as your battery cables, and spark plug wires. You really don't need to do or add anything as long as it runs and everything works that needs to work, it'll be fine. I'm going by memory, so if I forgot something I apologize, but that's the best of my recollection right now. If you have anymore questions you can email me.
- Q: Hello,I'm trying to replace my old ceiling fan with a new one but i can't seem to figure out the wiring.I have three wires coming out of the ceiling: 1) Two white ones that were connected together when the old ceiling fan was installed2) A grey wireI have four wires in the new fan:1) Black2) Black and White (would connect with the black based on the instructions)3) Green Grounding4) WhiteCan you help me figure out the connections. Thanks!
- the two connected means a continous circut. Means it goes to something else. Tie the two blacks, from the fan with the grey. Your fan must have a light. And the white to the white. Your just compleating the circut. Cant really mess it up. green is ground ofc
- Q: How do electric and other companies decide on strung wires in consideration of snowfall?
- Utility companies use a set of standards to determine the maximum tension in pounds that will occur on a wire due to wind, ice, temperature, wire size, wire type, span length, and support structure strength (poles). The normal loading criteria is based on a 8 pounds per square foot wind loading, ?” of radial ice at 0 degrees F. The NESC limits the conductor tension to 60% of the maximum rated tension of the conductor used or 2000 pounds, whichever is lowest. Hope this helps, Newton1Law
- Q: For my braces, the top wire where my two front teeth are, I can push the wire and it sort of bend. I don't know if this is normal or not. Can someone tell me?
- Well im 16 and have had my wire braces for 2 years, and all my neighbors have wired braces, but i believe the invisible braces ive seen appear dangerous, like they have somthing on they are tooth. At the least with wired braces everybody knows its braces and no longer some crap you've got on you tooth thats suposed to be invisible.
Send your message to us
Binding Iron Wire Black Annealed Iron Wire 16g with High Quality
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 25000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords