Assembled prefabricated branch cable FZ-ZRVV
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
I. Characteristics of the cables
1. Using factory prefabrication methods can substantially reduce the site construction labor intensity and shorten the construction laying time;
2. Use of cables can guarantee great length and bending property, and greatly facilitates the construction in a complex place;
3. Use of cables reduces the laying space, and cables can be installed together with gas and hydraulic gas pipelines;
4. Their reliability and reliability can be fully guaranteed, for the cables are manufactured in the factory,
5. Sub-branch parts should use high strength sealed joints, which are waterproof and have properties of moisture protection, long-term maintenance and free for repair;
6. Because the cables are directly connected with households with no need of maintenance and repair and with easy and simple construction, the cables can produce significant comprehensive economic benefits.
II. Usage of the cables:
1. To be used for high-rise building;
2. To be used for disaster prevention equipments;
3. To be used for tunnel lighting and disaster prevention equipments;
4. To replace copper bus bar with small or medium capacity in various places.
III. Standards of the cables
IEC 60502 Rated Voltage 1 ~ 30KV extruded insulated power cables and accessories (International Electrotechnical Commission standards)
GB 12706 Rated voltage 35KV and below Copper core, Aluminum core plastic insulated power cable (National Standard of the People's Republic of China)
JCS 376 branch cable (Japanese Electric Wire Industry Standard)
General Rules for JIS C2810 indoor wiring electrical connection pipes (Japanese Industrial Standard)
Types of the cables::
Standard main cables and branch cables are all low-voltage power cables with XLPE or PVC insulation materials (IEC, GB, JIS, BS ... ...), and PVC materials covered on the outer side. Generally, the main cable is single-core or twisted multi-core cable (cables with two to five cores), the branch cables are single-core cables, and may adopt a fire-resistant, flame retardant cables in accordance with the requirements.
Their structures and types are as follows:
No. | Cable Description | Type | |||
single core | three cores twisted type | four cores twisted type | five cores twisted type | ||
1 | PVC insulated PVC sheathed branch cables | FZ-W | FZ-W-3 | FZ-W-4 | FZ-W-5 |
2 | PVC insulated PVC sheathed flame-retardant branch cable | FZ-ZRVV | FZ-ZRVV-3 | FZ-ZRVV-4 | FZ-ZRVV-5 |
3 | PVC insulated PVC sheathed fire-resistant branch cable | FZ-NHVV | FZ-NHVV-3 | FZ-NHVV-4 | FZ-NHVV-5 |
4 | Cross-linked polyethylene insulated PVC sheathed branch cables | FZ-YJV | FZ-YJV-3 | FZ-YJV-4 | FZ-YJV-5 |
5 | Cross-linked polyethylene insulated PVC sheathed flame-retardant branch cables | FZ-ZRYJV | FZ-ZRYJV-3 | FZ-ZRYJV-4 | FZ-ZRYJV-5 |
6 | Cross-linked polyethylene insulated PVC sheathed fire-resistant branch cable | FZ-NHYJV | FZ-NHYJV-3 | FZ-NHYJV-4 | FZ-NHYJV-5 |
- Q: I noticed many of our server cables are thicker than the standard ones for a desktop PC. Would any power cable work, regardless of gauge? I want to use shorter server power cables for cable management purposes, since some of our server cables are over 10-15 ft. in length and only need 3 ft. or so.
- You could shorten the cables, but you shouldn't use a smaller gauge. The gauge of the power wire is sized appropriate to the power supply of the server. If you use a wire that is to small a gauge you could create a fire hazard.
- Q: Does it also come with the cable that connects it to the monitor? Thanks!
- Yeah, it comes with a three prong power cable and a bunch of internal cables, one or two for the motherboard, one or two for graphics cards, and a bunch for drives.
- Q: should you run RCA cables and power next to each other?
- you can but its always best to run them apart for the least possible interference.
- Q: I mean like the power connector cables. All power supplys have the same cables to supply power from the PSU to components right?
- not all PSUs have the same cables but they do all come with the same standard connectors. for example all PSUs regardless of wattage and brand will have the 4 pin molex conectors but not all will have the 6 pin and the 8 pin PCIe connectors and the higher end models will also come with 2 CPU 4 pin power connectors. which PSU you get depends on wattage demand of your system, amperage demand if you have a video card requireing extra power and the number of molex/sata power cables and PCIe 6/8 pin connectors you need.
- Q: I have a dell xps 420 and I wanted to replace the power cable as it's broken, the cable according to the specs looked like this http://cl.ly/image/311R232N120a and http://cl.ly/image/3L2C1h2V3C1X. Where can I buy the same exact cable with the same color code? I tried looking at OKorder, but didn't see any
- If you are located outside USA, let me know so that I can provide you the correct information. Let me know if you need any further support. I will be glad to help you. Dell-Niranjan
- Q: Its on power and one is in a pc monitor and one is lying on the ground. Will the electricity go through the cable that is not connected and lying on the ground? is this safe to touch with hands or shoes?
- Pasting the reply I gave to the other (deleted) question: Assuming these are the IEC-standard power cables I'm thinking of, yes and no respectively. Electricity will be able to reach both ends, but the plastic insulation at the end of these connectors should disallow any contact between you and the live pins. You may want to consider covering it up in non-conductive electrical tape, though, just to be sure no debris get in causing it to go live outside of the connector.
- Q: I am currently travelling in Europe and my power cable crapped out. I need a website which offers next-day international shipping. I am currently in Prague and am going to Krakow next; so if you know of a store in either city which would save me the shipping costs, that works, too.
- polish okorder / all apartments have printers regards
- Q: Were can i buy a replacement power cable ?
- You okorder which the only few i know offer the power cable charger under lifetime warranty. Since those power cable won't last forever, lifetime coverage can definitely save your some money. Wish the Best.
- Q: I recently purchased a Nvidia 8300gs for PCI-E x16.I know that not all graphics cards need a power cable but i'm going to buy one partially because the seller said PCI-E power cable required so is this a common item? would i be able to pick one up at best buy?
- If okorder and order it online, they might not have them at Bestbuy.
- Q: What is the difference between the power cable yjv and the vv cable? In the use of what to pay attention to? What is the difference between selection? Online ~~~ more
- I have to integrate a graphics card, you buy a separate graphics card is really a waste of money now I also listed, showing a lot stronger than the 2100 performance, and the market in the low-end discrete graphics upstairs you upstairs a lot of results Even a display did not give people with the price exceeded
Send your message to us
Assembled prefabricated branch cable FZ-ZRVV
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches