Product overview
XBD series compared with previous fire pump, its with the pump outlet pressure differential between the reduced flow specification, minimum of only 0.05 MPa. The spectrum density increasing, the distribution is more reasonable, can better meet the needs of different floors and pipe resistance of fire control, meet the design selection. XBD series product is reached leading level, cover an area of an area small, light weight, low noise, good performance, the advantage of reliable running.
Application field
When the suitable operating mode
Flow range: 2.5 L, 200 L/S
Pressure range: 0.11-2.38 Mpa
Liquid temperature: 80 ℃ or less water
Product features
Low XBD series centrifugal fire pump can be divided into; Vertical single-stage, vertical multistage single export-oriented, horizontal multistage export-oriented, vertical multistage export-oriented, horizontal multistage export-oriented
Low XBD series centrifugal fire pump adopts copper alloy, copper alloy impeller pump shaft seal ring, stainless steel, ensure "at any time is up and running"
Low vertical/horizontal multi-stage export series satisfy the needs of high-rise building points to distinguish the pressure
Low horizontal multi-stage more export series intermediate exports may be two types of installation: vertical, horizontal direction
Low level at the end of the series vertical multistage exports more exports and export can be installed in four directions: middle inlet direction compared to 0, 90, 180 o, o o 270 o
Low horizontal multi-stage series is suitable for installation at a lower height of vertical space
Low vertical multistage series is suitable for the place more compact space
- Q: Must the water pump in the tank be all soaked in water?
- Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
- Q: Does vacuum pump oil belong to dangerous goods?
- Of flammable substances, but not included in dangerous goods!Does not belong to dangerous goods,
- Q: Why should I pump the pump before starting the centrifugal pump?
- Only centrifugal water can be pumped out of the centrifugal blade to generate negative energy at the entrance. There is no water diversion. Only the negative pressure produced by the air is too low to absorb the well water.Water pump has been pumped, centrifugal pump or can not start normally, mostly because of the water pipes and air
- Q: What are the constant pressure pumps?
- Constant pressure pump is also called the booster pump, the name is used for booster pump, its main purpose is water heater booster, with tall low pressure, sauna, bath and other pressure in the apartment, the lack of water pressure, solar automatic pressurization and so on.
- Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
- Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
- Q: Is vane pump good or gear pump good?
- The main working parts of vane pump is provided with a plurality of sliding vane rotor, when the rotor rotates, the eccentric configuration of stator cavity contour or rotor, blade sliding slot in leaves due to volume changes, resulting in the suction effect. The similarities are: 1, rotary type positive displacement pump has self-priming ability, but are not allowed to do; 2, with continuous flow pulsation, but also have flow and pressure; 3, the theory of flow is determined by the working parts of the size and speed, has nothing to do with discharge pressure; 4, rated discharge size, pressure and working parts mainly depends on the pump speed is independent of the sealing parts and bearing capacity; differences: 1) gear pump structure is more simple, reliable, low price; vane pump has complicated structure and high manufacturing precision parts, the blade is easy to get stuck, more sensitive to the oil clean degree and viscosity.
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- What you should say here is the concrete pump.Ground pump: the pump will be placed in a position on the site, the pipeline will be sent to the construction of concrete surface,
- Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
- Working pressure - the actual working pressure of the motor, that is, the pressure of the input oil. The difference between the motor inlet pressure and the outlet pressure should be calculated.Rated (nominal) pressure under normal working conditions, according to the test standards for continuous operation of the maximum pressure, that is, the rated pressure, more than the maximum pressure is called overloading.
- Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
- The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
- Q: Significance of water pump model ISO50-160
- Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.