• XBD-DW series horizontal multi-stage single-suction fire pump System 1
XBD-DW series horizontal multi-stage single-suction fire pump

XBD-DW series horizontal multi-stage single-suction fire pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product overview

XBD series compared with previous fire pump, its with the pump outlet pressure differential between the reduced flow specification, minimum of only 0.05 MPa. The spectrum density increasing, the distribution is more reasonable, can better meet the needs of different floors and pipe resistance of fire control, meet the design selection. XBD series product is reached leading level, cover an area of an area small, light weight, low noise, good performance, the advantage of reliable running.

Application field

When the suitable operating mode

Flow range: 2.5 L, 200 L/S

Pressure range: 0.11-2.38 Mpa

Liquid temperature: 80 ℃ or less water

The working conditions

Low XBD series centrifugal fire pump can be divided into; Vertical single-stage, vertical multistage single export-oriented, horizontal multistage export-oriented, vertical multistage export-oriented, horizontal multistage export-oriented

Low XBD series centrifugal fire pump adopts copper alloy, copper alloy impeller pump shaft seal ring, stainless steel, ensure "at any time is up and running"

Low vertical/horizontal multi-stage export series satisfy the needs of high-rise building points to distinguish the pressure

Low horizontal multi-stage more export series intermediate exports may be two types of installation: vertical, horizontal direction

Low level at the end of the series vertical multistage exports more exports and export can be installed in four directions: middle inlet direction compared to 0, 90, 180 o, o o 270 o

Low horizontal multi-stage series is suitable for installation at a lower height of vertical space





Q: 5 floor water pressure is too low, what kind of water pump is better?
Pipe blockage, leaks, or throttling devices are not opened. This can be tested on a pipe with a pressure gauge;Water pump is equipped with power source, power or speed does not match, check the pump and power end nameplate, power end of the pump power is generally 1.1.5 times;
Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
[suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
Q: What is the Rhodes pump?
Work principle editorRoots-type pump is a vacuum pump without internal compression, usually compression ratio is very low, so high and medium vacuum pumps need pre pump.A vacuum pump for pumping air by pumping a gas by the simultaneous rotation of a pair of lobed rotors in a pump cavity and a reverse rotation.Roots vacuum pump is a mechanical vacuum pump with a pair of synchronous and high-speed rotating sole shaped rotors. The pump can not be drawn out separately. The front stage needs to be equipped with an oil seal and a water ring, etc. it can be discharged directly into the atmosphere.
Q: What are the functions of a disposable infusion pump?
When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
Q: Why can't the inlet of centrifugal pump be negative pressure?
Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
Q: How many kinds of pumps are available and the operating principles of various pumps?
There are many kinds of pumps. There are different classifications according to different standards. If classified according to the principle of work, can be broadly divided into the following four categories:1, vane pumps: centrifugal pumps, axial pumps, mixed flow pumps, vortex pumps, etc.;2, displacement pumps: piston pumps, piston pumps, diaphragm pumps and so on;3, power rotary pump: screw pump, gear pump, etc.;4 、 special function: jet pump, water hammer pump, magnetic drive pump, etc.;
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
Q: Is the centrifugal pump large or small?
When the liquid is lowered at a certain temperature to the vapor pressure at this temperature, the liquid bubbles. The phenomenon of producing bubbles is called cavitation. When the bubbles are flowing to the high pressure, the volume of the bubbles is reduced so that they are destroyed. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse. The local pump is in operation if the over-current part (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began there, produce a lot of steam bubble formation, when the liquid contains a lot of bubbles by forward high pressure impeller Zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst and the liquid particle at high speed to fill a hole in this moment has a very strong effect of water hammer and the impact of high frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be. The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also produce noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q: What flowmeter is installed after the pneumatic diaphragm pump?
The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches