Standard Hot Dipped Galvanized Iron Wires 2.2mm
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 1500 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Commercial Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool | ||
0.27-0.60 | 8 inch | 1-100kg/spool | ||
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 | 14-500kg/spool | 450 | 800 | |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 | |||||||
≤0.25 | 30 | 20 | 18 | |||||
>0.25-0.40 | 30 | 25 | 20 | |||||
>0.40-0.50 | 30 | 20 | ||||||
>0.50-0.60 | 35 | 20 | ||||||
>0.60-0.80 | 120 | 110 | 40 | 20 | ||||
>0.80-1.00 | 150 | 130 | 45 | 25 | ||||
>1.00-1.20 | 180 | 150 | 50 | 25 | ||||
>1.20-1.40 | 200 | 160 | 50 | 25 | ||||
>1.40-1.60 | 220 | 180 | 50 | 35 | 30 | |||
>1.60-1.80 | 220 | 180 | 70 | 40 | 30 | |||
>1.80-2.20 | 230 | 200 | 80 | 50 | 40 | |||
>2.20-2.50 | 240 | 210 | 80 | 55 | 40 | |||
>2.50-3.00 | 250 | 230 | 90 | 70 | 45 | |||
>3.00-4.00 | 270 | 250 | 100 | 85 | 60 | 30 | ||
>4.00-5.20 | 290 | 270 | 110 | 95 | 70 | 40 | ||
>5.20-6.00 | 290 | 270 | 245 | 110 | 100 | 80 | 50 |
- Q: How can I stop my cat from chewing wires? He does it all the time, and the wire he ends up being important.
- Kittens in particular are very curious and play with everything that comes in their way. Remember that they are inexperienced like toddlers and try everything at least once. Make your home as kitten-proof as possible. Problem Keep an eye on kittens when they are young and very inquisitive. Dangling cords are particular attracting to them and dangerous if chewed through. Electric shock can be the result. Solution ? Put something distasteful on the cord to discourage chewing ? Tabasco sauce, cayenne pepper, bitter apple/orange, orange/lemon peel, commercial repellents ? Gaffer’s tape (available in diy stores) will probably work if the substances don't ? Secure exposed cords ? Consider permanent wiring if you own your place
- Q: A load of 125 kip is being held by 3 wires all going up. The Wire one goes straight from the load to the horizontal. Wire 2 and 3 form a V on top of wire 1 and are 30 degrees from wire 1. This is a 2-D problem.
- You need to use summation of forces. Wires 1 and 2 are gonna have the same tension on them, just in opposite directions. so in the x direction, Fx=125cos(30)+125cos(150) (the vertical wire doesn't contribute to the x-direction forces and I choose 150 because the wire on the left really has an angle of 180-30 or 150) in the y direction, Fy=125sin(30)+125sin(150)+125sin(90) (The vertical wire is a 90 degree angle) Tension=sqrt( Fx^2 + Fy^2 )
- Q: Or speaker wire that has an RCA plug on one end?If you know of something that is inexpensive without me having to get another preamp, please help.(this is for a turntable preamp by the way, my preamp only has RCA output.)
- do not use speaker wire for the turntable preamp!! use RCA cables. speaker wire is balanced wire, both conductors are identical. RCA connectorized wire is coaxial, shielded and unbalanced. You need the shielded coaxial unbalanced wire.
- Q: Wire 1 and wire 2 are made from the same metal. Wire 2 has a larger diameter than wire 1. The electric field strengths E1 and E2 are equal. A) Compare the values of the two current densities. Is J1 greater than, less, or equal to J2?B) Compare the values of the currents I1 and I2. Is I1 greater then, less or equal to I2?
- The current will be more dense in the smaller wire. The value of the current is inversely proportional to the resistiance of the wire. Resistance = resistivity * length / Area since the wires are of identical material and length, the only thing left to vary is the cross-sectional area. Area is proportional to the square of the radius (diameter), so the current will be proportional to the square of the diameter. I2 is proportional to I1^2 I2 is larger than I1 .
- Q: Wires in the dash*Radio constant*Radio Switched*Radio illumination**please match these up with the options below**Wires on the stereo itself*Dashboard Light Dimmer Switch*Amplifier Remote or Power Antenna (Positive +)*(fuze) yellow memory (negative -)*(fuze) red 12v (positive +)if someone could please help that would be great-since the wires were replaced i cant go by color
- Car radio wire constant to stereo yellow memory. Car radio wire switched to stereo red 12v positive. Car radio wire illumination to stereo Dashboard Light Dimmer Switch. Don't forget to ground the black wire on the unit to the ground wire from the car harness. An extra ground strap to the chassis is a good idea also. If you don't have an amp or a power antenna, cap off the blue Remote/Antenna wire.
- Q: Please help,I have a 1993 Jeep Grand Cherokee LaredoThe wire harness on the hitch has 7 wires,The whole thing is shot,My Question is can i just wire in a 4 prong harness, On my trailer yellow is left turn-green is right turn-brown is stop tail, white is ground The Jeep has 7 wires a green-a tan- a brown w green stripe-a blue w red stripe-a red w blue stripe and a bigger light blue and a bigger black, can i splice into these or do i have to get a converter of some sort ,Any idea'sTHANK YOU
- Not sure about Jeep's color code. If I were doing this job, I'd just use a test light. Turn on left turn signal, find the wire that's flashing (w/test light), butt splice the yellow wire. Do this with three wires yellow, green, black. Green for right turn, and black for tail. White is the ground. Brake lights go thru turn signal switch so no worry there, uses same filament as turn signal. Black is hot with headlights on. (BTW brown is Clarence lights, not to be combined with red, stop lights).
- Q: Why when you loop a straight wire into loops (coil), it acquires a higher inductance?
- If the ends of the wire are joined to form a circuit each loop forms a path for induced current, the currents of each loop are accumulative.
- Q: The black wire is called ground but what is the red wire called?
- In single phase AC circuits it's hot (ungrounded). In three phase AC circuits it's A phase. In DC circuits it's positive.
- Q: what are the ground and power wires for a walmart replacement cigarette lighter?
- The wire that leads to the center terminal is the power wire. The wire that is attached to the case or side of the unit is the ground side.
- Q: I have a 2 wire system in my garage and need to update to a 3 wire grounded plug. Can I leave my existed 2 conductor and just run a single 12 gauge insulated ground in the same conduit back to the panel/grounding rod. Or do I need to pull out the 2 wore replace with 3 wire ?
- You can just add a wire. If you have metal conduit and metal j-boxes all you have to do is connect a ground to the box. NEC 250.118 Types of Equipment Grounding Conductors. The equipment grounding conductor run with or enclosing the circuit conductors shall be one or more or a combination of the following: (1) A copper, aluminum, or copper-clad aluminum conductor. This conductor shall be solid or stranded; insulated, covered, or bare; and in the form of a wire or a busbar of any shape. (2) Rigid metal conduit. (3) Intermediate metal conduit. (4) Electrical metallic tubing... But if not in metal conduit then you can connect it to the first 5 feet of metal water pipe, the ground rod, the wire leading to the ground rod/metal water pipe, or the ground bar in the source electrical panel. NEC 250.130(C) Nongrounding Receptacle Replacement or Branch Circuit Extensions. The equipment grounding conductor of a grounding-type receptacle or a branch-circuit extension shall be permitted to be connected to any of the following: (1) Any accessible point on the grounding electrode system as described in 250.50 (2) Any accessible point on the grounding electrode conductor (3) The equipment grounding terminal bar within the enclosure where the branch circuit for the receptacle or branch circuit originates (4) For grounded systems, the grounded service conductor within the service equipment enclosure
Send your message to us
Standard Hot Dipped Galvanized Iron Wires 2.2mm
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 1500 m.t./month