Type LDTN condensate pump are used for pumping condensating water in condenser of thermal (nuclear) plant, also be used for pumping other media which are similar to water
in physical and chemical properties.
Its range of performance are as follows:
Capacity: 120~530m³ /h
Head: 48~360m
Media temperature: normal 80 ℃(special up to 120 ℃)
Type LDTN condensate pump are a vertical muilt-stage columnar pump, suction and dischar nozzle are respectively aranged on the barrel and discharge seat and both can be altered
on place of 180° , 90° or many degrees; the impeller is closed type
The pump has water-lubrication berings so that bear redial thrust of rotor. Axial thrust of rotor is balanced by thrust bearing or motor.
Pump rotor and line shaft are connect by cutting colummar coupling, pump rotor and motor shaft are connected by elasticity cylinder pin coupling.
Shaft seal is soft-packing, the mechanical seal can be assembled according to special requirements.
- Q: What is the difference between swashplate pump and crankshaft pump?
- Piston pump: valve plate, valve plate, piston, piston ring, crankshaft, connecting rod and so on, all belong to its spare parts.Piston pump working principle: by the piston in the pump cylinder for reciprocating movement to suction and remove liquid.
- Q: Must the water pump in the tank be all soaked in water?
- Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
- Q: Why should the pump be closed when the centrifugal pump is started?
- Centrifugal pump has an important characteristic: when the pressure (head) is very low, the flow will be great, which can be seen from the characteristics of the pump curve. While the pump power is directly proportional to the flow rate, pump start, no pressure in the pipeline, caused by the pump flow, high power pump, and the pump motor, the rotating part from rest to high-speed operation, need a lot of acceleration, it will cause a great starting current
- Q: What is the minimum continuous flow of a pump?
- The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
- Q: Why should I pump the pump before starting the centrifugal pump?
- 1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
- Q: What are the characteristics of a vertical multistage centrifugal pump?
- Vertical multistage centrifugal pump system using the latest international advanced IS type hydraulic model based design for high efficiency centrifugal pump with multi segment, the soft packing or mechanical seal, has the characteristics of high efficiency, large flow, high lift, no leakage, a wide range of performance, safe operation, stable operation and long service life and small area.
- Q: Harm of air pump and pump
- Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
- Q: What is a feed pump?
- In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
- Q: What is the cause of the damage of pump bearings?
- In high-speed equipment, the most likely damage to bearings is high temperature.
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.