1.  Description of solar pumps. 

CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.

 

In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

 

2. Technical Function

1>  High efficient DC brushless motor requires less solar array. Rich social benefits.

2>  Optional centrifugal pump for big flow and helical rotor pump for high lift.

3>  High efficient semiconductor device used in main circuit. High reliability. Up to 98% conversion efficiency  of controller.

4>  Independent intellectual property of dynamic VI maximum power point tracking (MPPT) algorithm. Fast  response  and good stability. 99% MPPT efficiency.

5>  Full automatic operation. Complete protection functions. Integrated with water level monitor to prevent

  overflow and dry running.

6>  Full aluminum alloy case. IP52 protection grade. Ambient temperature: -20~+60.

Product Specifications


3. Specification details. 

1> Flow: 0.4m³/h~22m³/h

2> Head: 10m~210m

3> Power: 0.1~3Kw

 

4. FAQ

1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?

     The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements. 

2> Does your controller have the MPPT Function?

     Yes, our controllers have. This would be not a problem. 

3> Can your pump work automatically?

     Yes, it would be the basic advantage of solar water pumps. 


Solar Pump Irrigation Systems Based On AC and DC

Solar Pump Irrigation Systems Based On AC and DC


Q: Fire hydrant pump button, under what circumstances do not need to install?
There are four things to do:Fire hydrant button to meet the requirements of national standards.In addition to pumping, it can show the location of fire.
Q: Troubleshooting of diaphragm pump
The troubleshooting guide for diaphragm pumps, when encountered in one or more of the following situations, this information can be used as a guide to help you develop maintenance measures.As shown below, some of the abnormal operating conditions described in this guide are: A) fast circulation / low flow B) no cycle / slow cycle / irregular cycle C) leakage D) noise E) component rupture
Q: The function of centrifugal pump
2, pump body, also known as pump shell, it is the main body of the pump. The utility model is provided with a supporting and fixing function and is connected with a bracket for mounting the bearing.3, the role of the pump shaft is to use the coupling and motor connected, the motor transfer distance to the impeller, so it is the transfer of mechanical energy of the main components.
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q: Advantages and disadvantages of centrifugal pumps?
The uniform liquid no pulse phenomenon.(2) shortcomingsBefore running, the pump must be filled with liquid.For the supply of small flow, large pressure head inappropriate, inefficient and limited.Encountered imperfect design or operation is not at the time, such as milk, it is easy to produce foam, affecting the next process production.The installation is wrong. There will be "Qi tie" phenomenon.The efficiency is also lower than the reciprocating pump.The sources of knowledge are absolutely reliable!!!!
Q: How many kilograms of water pump are there in the automatic washing machine on the market?
Longer service life. Automatic switch water pump, car wash automatically open and stop, easy to operate, not easy to bad, repair rate is low!!!
Q: How high can the pneumatic diaphragm pump be?
If the pump material made of polypropylene (PP) material, corrosion resistance, good chemical resistance using PP material produced by pneumatic diaphragm pump can resist medium low cost, good generality, polypropylene material mainly is especially suitable for general acid-base liquid, using poly propylene made of plastic gas diaphragm pump can only withstand the highest temperature to 65 degrees, more than this number of polypropylene plastic deformation.
Q: Why is the flow of the pump too small will occur cavitation phenomenon?
This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
Q: How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy