• Single-Stage Double Suction Water Pump for Irrigation System 1
  • Single-Stage Double Suction Water Pump for Irrigation System 2
  • Single-Stage Double Suction Water Pump for Irrigation System 3
Single-Stage Double Suction Water Pump for Irrigation

Single-Stage Double Suction Water Pump for Irrigation

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Single-Stage Double Suction Water Pump for Irrigation

1.Structure of Single-Stage Double Suction Water Pump for Irrigation Description

End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.

End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.

2.Main Features of Single-Stage Double Suction Water Pump for Irrigation

very easy to be installed and maintained

Back pull-out design

•Driven through flexible coupling

•Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.Single-Stage Double Suction Water Pump for Irrigation Specification

 

Material

Cast iron

Pump diameter

350-1600mm

Flow range

1~200L/s

Pressure range

0.2~2.25MPa

Motor power range

1.5~200kW

Inlet/outlet Diameter

DN50~DN200mm

 

Casing

Cast Iron Standard, Ductile Iron, Stainless Steel Optional

Impeller

Bronze Standard ,Cast Iron, Stainless Steel Optional

Shaft

ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional

Shaft Seal

Mechnical Seal, Gland Pakcing Optional

 

Flow rate

2-1100m3/h

Head

2-152m

Speed

1450 or 2900(50hz),1750 or 3500(60hz)

Working Pressure

1.6PMa or 2.0PMa

 

4.Picture of End Suction Pump

Single-Stage Double Suction Water Pump for Irrigation 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

 

 

 

 

 

Q: What are the general water pump failure, how to repair?
(4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,
Q: What is a positive displacement pump? He Weizheng displacement?
And includes a pump chamber (24) to open and a channel is arranged between the entrance and the pump chamber (26) in the second one-way valve (15), and one for the continuous displacement member (13) in the pump shell (10) in the travel section (S) actuating mechanism reciprocating motion.
Q: Why is the flow of the pump too small will occur cavitation phenomenon?
Why is it easy to produce cavitation when the inlet flow of pump is lowered?This is because the main performance parameters such as the head, power and efficiency of the centrifugal pump are not fixed, but vary with the flow rate. The curve drawn on a coordinate paper is called the performance curve or characteristic curve of the centrifugal pump. What happens when the flow rate decreases? The disadvantage of throttling adjustment is that the pump flow is small, and the impeller is easy to cause cavitation
Q: What are the problems that should be paid attention to when using vacuum pumps?
(14) vacuum pump used in the winter season, after stopping the pump body, lower drain plug unscrew medium on the net. To prevent cracking.(15) the vacuum pump has been disabled for a long time. All the pumps should be taken apart and dried. The rotating parts and the joint should be coated with grease and properly preserved.
Q: Why is the sewage pump device coupler?
2. automatic coupling device of the sewage pump coupling device has compact structure and small occupation area. Because the sewage pump is submerged, it can be installed directly in the sewage tank, and no special pump room is needed to install the pump and pump. It can save a lot of land and infrastructure costs.
Q: What's the difference between a concrete pump and a concrete pump truck?
Concrete pump and concrete pump truck are concrete conveying machinery, use the same, but the former need to transport and car towing need additional support pipeline, the locomotive body and arm extends freely, without pipeline, hundreds of thousands of millions of the former, the latter
Q: Types and differences of pumps
(I) volumetric typeClassification reciprocating rotary typeThe basic principle of reciprocating action by the piston in the cylinder in the cylinder volume changes again, with the suction and discharge of fluid in the shell or the rotor rotating member rotates, the volume of work between rotor and casing changes to the suction and discharge fluid, such as piston pump gear pump, screw pump(two) blade type;The main structure of vane pumps and fans is rotary, bladed impellers and stationary housings that rotate fluid through the impeller to do work, thereby enabling fluids to obtain energy
Q: How accurate is the metering pump?
In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords