Single Stage Double Suction Centrifugal Water Pump for Pump Station
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Single Stage Double Suction Centrifugal Water Pump for Pump Station
1.Structure of Single Stage Double Suction Centrifugal Water Pump Description
Split Casing Double Suction Centrifugal Water Pump is a single-stage centrifugal pump, horizontal in the open, for the transport of water and physical and chemical properties similar to water in liquid, the liquid temperature should not exceed 80 °C, suitable for factories, mines, power plants, city drainage, drainage irrigation and water conservancy
2.Main Features of the Single Stage Double Suction Centrifugal Water Pump
• Compact structure, good appearance, low construction
•Operation stably, same inlet and outlet
•Convenient installation and maintenance
•Customized design is available, OEM and ODM are welcomed.
•Horizontally and vertically installation as different pipeline system
3. Single Stage Double Suction Centrifugal Water Pump images
4. Single Stage Double Suction Centrifugal Water PumpSpecification
Item | Agricultural irrigation water pump |
Electric irrigation water pump | SH series agricultural irrigation water pump |
Model | SH |
Material | Cast iron and customized |
Color | Blue and adjustable |
Mode | Horizontal |
Impeller | Double suction impeller |
Drive | Belt or coupling |
Seal | Soft packing seal or mechanical seal |
Speed | 2950r/m, 1470r/min, 970r/min |
Theory | Centrifugal pump |
Structure | Single stage pup |
Usage | Pure water or raw water |
Power | Electric |
Standard or Nonstandard | Standard |
Application | Plant, mine, power station, urban water supply, irrigation |
Outlet diameter | 100-900mm |
Capacity | 111-12500m³/h |
Head | 8.6-140m |
Power | 22-1250kw |
Warranty | 1year |
Certificate | ISO9001 |
OEM | Acceptable |
Feature | High flow rate, high efficiency, easy maintenance |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: Why does the centrifugal pump close the pressure to start?
- The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
- Q: Troubleshooting of diaphragm pump
- The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
- Q: What does the pump mortar do?
- 1: 2 cement mortar or cement mortar with the same proportion of other components except coarse aggregate in the concrete, the pump piston and the inner wall of the pipeline are fully lubricated, and a layer of lubricating film is formed
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Indoor fire hydrant pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, but also fire hydrant button, direct pumping function, a total of three functions.Outdoor fire hydrant pump in addition to remote direct Kai, but also an electric contact pressure meter detection system, water pressure from the pump and high pressure pump stop function.
- Q: Advantages and disadvantages of centrifugal pumps?
- Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
- Q: Why should I pump the pump before starting the centrifugal pump?
- Only centrifugal water can be pumped out of the centrifugal blade to generate negative energy at the entrance. There is no water diversion. Only the negative pressure produced by the air is too low to absorb the well water.Water pump has been pumped, centrifugal pump or can not start normally, mostly because of the water pipes and air
- Q: What is the difference between centrifugal pump and rotary vane pump? What are the distinctive characteristics or principles of rotary and centrifugal? O (a _ U) O thank you!
- The vane pump can be divided into centrifugal pump, mixed flow pump and axial flow pump according to the direction of liquid flow in the impeller.Centrifugal pump is a kind of vane pump, which is the most widely used.
- Q: Is the flow meter in front of the pump or after the pump?
- After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better
- Q: What's the word "pump"? Is that what advocates mean?RT
- Is generally believed that the "wholesale" is the "hoarding" of "hoarding" variant, can be used to replace the word "store". And "wholesale" compared to "store" is clearly better and better recognize, because the "store" is a phonogram, hoard shaped characters "mouth", said the biggest the range of aggregation, like a grain bin; "Tun" is also phonetic, semantic. Tun, originally refers to the grass speared out of shape, with curly tails, and gathered the meaning.In this case, the "fans" can be written as "Yong Tun". But this is also troublesome, because the "store" in addition to read "Tun" (Ping Sheng), another pronunciation of "Dun" (Qu Sheng), who said food utensils, when we had the "Valley" store. So, if the "fans" to "hold", is also wrong. "Bin Zhao Wei fans" although it sounds strange, but at least not ambiguous; if changed to "Zhao Wei", is that we have to hoard may hear "Zhao Wei" or "Zhao Wei hold hip", hold the shield this is not the more the more chaotic change it!It is suggested that the "fans" to "fantastic", the modified method was acceptable. In modern Chinese, "public" does not necessarily mean that many, can also refer to a single. "One of the masses", "one of the audience (or audience)" this kind of argument, has been about good. Since this kind, we say "a fantastic" what not? "Fantastic" at least than the "fans" straightaway. The problem is, the word and Hong Kong Standards, there is no "fantastic".
- Q: What is the cause of the damage of pump bearings?
- Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Send your message to us
Single Stage Double Suction Centrifugal Water Pump for Pump Station
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords