Production Introduction for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
Voltage Rate: 300/500V, 450/750V
Range of Nominal cross section: 0.75 mm2 ~ 630 mm2
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Constructions Insulation: XLPE or LSZH material
Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature: 70 ℃ , can be 90 ℃ ,105 ℃ and 125 ℃ as per
requirement
Packing: 100 meter/roll or as per requirement
Application for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
These cables is with features of fire retardant, low smoking and halogen free, it is applied to fixed installing with heat resistance requirement of the places with a special demands of flame retardancy, the density of smoke emission and toxic index if the cable is burnt, such as subway, tunnel, nuclear power station, etc.
Production Standard for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
I EC 60332, IEC 61034, IEC 60754, BS 7211 , HD 22.9, VDE0282, GB/T19666
The Feature for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
The cable can be of flame retardance, fire resistance and other property
Packing photo for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
FAQ For Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
Q1:What is the Production Capacity for your factory?
About 80 kilometer every day
Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?
MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Q3:What is the delivery time for these cables?
10~15 working days
Q4: What standards is the product complying with?
We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.
- Q: My 4 gauge power cable is hooked up to the battery's positive terminal and the other end to my amplifier's terminal. Is it safe to accidentally touch the ring terminal (end) of this power cable? I won't feel any electrical shock or anything will I?
- if you touch the positive terminal with one hand, and any part of the car's frame or engine block with the other with the engine running at idle, you'll complete an electrical circuit that will put about 13 volts right through your chest. With the engine off, it'll be closer to 12.6 volts. Luckily, your body is a poor conductor, with a resistance of around about 200k to 500k ohms (2 - 5 hundred thousand ohms). Less if you're sweaty. At least, that's my resistance. That means you have about .026 milliamps (13 volts divided by 500k ohms x 1000) of electrical current running through your heart. But don't worry, that's a fraction of what it would take for you to even notice it. Of course, if you have an implanted pacemaker, all bets are off.
- Q: I'm trying to run a cable and power outlet into a closet for a media space but im not sure how to add the outlets in there. The area where the closet is, is on a wall that has no outlets and behind the closet is a bathroom which has no outlets on that side of the wall either so theres nothing to tap into. please help.thank you.
- if you mean a shower room then you cannot put electrical sockets in as it's illegal. Similarly you will blow the equipment up when it gets wet.
- Q: How can we manage power (voltage ) loss in the long distance if elcetricity is fed along with the cable?
- The repeaters use copper wire bundled together with the fiber optic to power the repeaters, the voltage drop is managed with an engineered choice of voltage and current. Each cable has a different combination to suite the particular distance. And each cable would be tailored for the individual application.
- Q: I managed to break off the tip of my laptop power cable to the point that I need it replaced. I can't pay with cash on OKorder and don't own a credit card. Anyone know an electronics store where I could find another? Thank you.
- Eee mini laptops use something referred to as an SSD complicated force or a stable State force. those are drives that have no shifting factors in them. THey perform very such as a USB flash force with in uncomplicated terms circuits and chips on them, no automobiles, no platters, no needles like complicated Drives. they are very rapid and extremely cool to assert the least :) With admire to those with cameras they are the fashions in the 900 and 1000 sequence that characteristic cameras. The seven hundred sequence ones have an non-compulsory digital camera on the 701 sort. have exciting at the same time with your new pc mini :) they are exciting Oh and additionally look at IBM, they make mini laptops too and additionally the recent MacBook Air is a mini pc, it extremely is particularly easy, slender and probable the best one :)
- Q: does anyone know a website that has like a chart with pictures of the different power supply connectors and where in the desktop computer they go all I know is the 24 pin goes to the motherboard and the 6 pin goes to my graphics card
- There are only a handful or so connectors on the modern ATX Power Supply. Pictures of the connectors or the adapters or extenders can be found in the manual for your motherboard (found in the manufacturer's website) or at online cable vendors (see link for one, below.) Sometimes an adapter or entender is needed due to the cables being too short - especially in the case where a new case has the power supply mounted on the bottom, rather than the top of the case.
- Q: What type of power cable does the ps3 take? I found a very good deal on craigslist, but it doesnt come with a power cord. Does ps3 take the standard 3 prong cable, like xbox 360? Or is it a special kind? And do all of the versions of ps3 take the same kind?
- My PS3 slim does not use the standard 3-prong power cord. However, Googling for images of PS3 power cords, it shows the standard 3-prong. So the answer yes or no.
- Q: Acoustic Audio 10 inch home theatre powered subwoofer use speaker wire or subwoofer cable?
- As you used the phrase The wire that was included for the subwoofer, I'll presume that we're talking Home Theater in a Box here. As someone above mentioned, sub frequencies can use a lot more energy. In a larger system where you are consistently running several hundred watts over longer distances, a larger wire would probably be benificial. For a HTIB system such as yours the wire that came with it would be more than adequate over the short run that would typically be needed. Having said that, there is nothing wrong and nothing will be damaged by going to a larger gauge wire. Just not a lot of benefit.
- Q: What is the meaning of YJVVV and VV22-4 * 25 + 16 in electrical appliances?
- General 2.5 square wire load is 2 kilowatts, and rubber sheathed cable, full load can reach 3 kilowatts are no problem (estimated again, it is not safe). The load level of the wire is mainly dependent on the current, but also on the voltage level. Under normal circumstances 50A below 1 square millimeter safe carrying capacity is 6A, 50 ~ 100A current 1 square millimeter of the safe carrying capacity is 5A, 100A current above the general take 1 square millimeter of the safe current is 2.5A; so many large square copper cable You can calculate the current. According to the three-phase alternating current formula: P = 1.732 * U * I * cosφ, cosφ is the power factor, select 0.8; this is the three-phase power calculation formula. Single phase: P = U * I * cosφ, cosφ is the power factor The power factor is 1 for the resistive load and 0.8 for the inductive load.
- Q: A network cable must cross a power cable. What can be done to minimize the amount of EMI?
- Use okorder / You would need two (one for each side of the connection)
- Q: Should I call 911 if a frayed power line fell in my driveway?
- Call the power company. Make sure you do not touch the line. Do not allow your children or pets near the line. There is nothing the police can do so calling 911 is not appropriate.
Send your message to us
Single Core LSZH material Insulated Fire retardant Cable 450 /750 VH07Z-U
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches