Rubber Insulated Ship Power Cable power transmission
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Introduction.;
It is suitable for power transmission in the water architecture such as all kinds of river or sea ship and sea petroleum platform.
Charactoricts:
The DC resistance of the fifth-class tinned flexible cord conductor shall be in accordance with the requirements stipulated in GB/T 3956.2、Burning test: it shall meet the single vertical burning test stipulated in JB/T18380.1; the uncarbonized part shall not be less than 50mm in length.3、Oil-immersed test: after being immersed in the oil solution at 100℃ for 24h, its tensile strength variation shall not be more than 40%, and the variation of its elongation at break shall not be more than 40%.4、Water-immersed capacity test: after the test, compared to the capacity on the first day, the increase percentage of the capacity on the fourteenth day shall not be more than 15%; compared to the capacity on the seventh day, the increase percentage of the capacity on the fourteenth day shall not be more than 5%.CharacteristicsEP-rubber insulated power cable has excellent property of electricity, heat-resistance and waterproof; flame-retardant, good buckling-resistance; its main characteristics are its performances of oil resistance, salt resistance and water proof as well as excellent anti-electromagnetic interfere and tensile resistance.
Specification
Type | Rated voltage kV | Number of core | Nominal cross-section mm2 |
CEF/DA,CEF80/DA,CEF90/DA,CEF82/DA,CEF92/DA CEH/DA,CEH80/DA,CEH90/DA,CEH82/DA,CEH92/DA CEV/DA,CEV80/DA,CEV90/DA,CEV82/DA,CEV92/DA CXF,CXF80,CXF90,CXF92,CXV,CXV80,CXV90,CXV92 CXFR,CEFR/DA,CEHR/D | 0.6/1 | 1 | 1~300 |
2 | 1~120 | ||
3 | 1~185 | ||
4 | 1~2.5 |
- Q:The specs say: 350 Watts, DC 12V, 100-240V. It is a Rackable server.Are there special / different power cables to use with servers than desktop PCs?Where can I find the power cable with the above specs. I tried OKorder with not much luck.
- Actually, There is no Different. The Point is make sure that the Cable to use for server is the Proper Cable to use for long term usage, and can plug properly to the Server.
- Q:The power company are doing some work on our road. and are going to be moving the terminal thing on the side of our house (2nd floor side wall) where the electric comes to the house and feeds both ours and next door (semi-detached). We have seen some dwellings that have a long UPVC bright orange plastic pipe covering the cable for a few meters and wondered why they do this?
- It is to protect the cable and people and animals. It stops animals chewing and protects in case of hitting the cable.
- Q:My laptop cable sometimes won't stay in all the time. When it is connected, it has a blue circle around it, but sometimes that blue circle goes off (while it is plugged into the side of laptop) and the tool bar changes from showing a plug to showing a battery. Would there be something wrong with the cable line and it needs to be replaced?
- the power plug is damaged and will have to be replaced the cost about 90 to 125 dollars. look at it and make sure if it is the plug or the socket
- Q:Hey,I left my PS3 in the living room, and I think the dog peed up it. Stupid place to leave it, I know. Anyway, I brought it back upstairs, hooked it up but when I went to plug the power cable in, there was a real loud buzzing sound coming from the PS3, right where the cable goes in. When I unplug it from the PS3, it stops. I tried leaving it to dry, and making sure there was no moisture present inside the machine, but I tried hooking it up again and got an electric shock up my arm from it.Should I buy a new cable, leave it to dry, or is there something inherently wrong with the PS3 now?Thanks :)
- Ive never come across this before. Maybe its because i don't no anyone who has a dog which has peed up there PS3. I would suggest you dont get a other cable because that one might break aswell due to water getting in your ps3. If i was you i would contact Playstation or the store you got it from for more advice. Like i say im not sure and i dont think many people will come across this problem.
- Q:HiI'm organizing my cords at the moment, but I'm curious, is it safe to use power cords (say a phone charger) when it is still wound up in a coil? It would save a lot of cord clutter, but are there any drawbacks, as in it would start a fire? Thanks
- There is no problem coiling the short cords that come with most devices. There isn't enough current to create a lot of heat. But don't leave long extension cords coiled up when you use them. The induction of the coil can limit the power to whatever is plugged into the cord. This can cause the device to overheat and burn out but it usually won't damage the cord.
- Q:Two things:1.) Why when we're using an AC to step up the voltage the power has to remain constant?2.) Why is it if we increase the voltage by a factor of 100 we have to decrease the current by a factor of a hundred and therefore I^2R is decreased by a factor of 10,000
- The principle is simple. VI=constant. Energy loss is proportional to I^2. If you want transmit power over a long distance, then V should increase. So the current will be small and energy loss will less. You can not use it because, high voltage gives more shock. When bring it near the home, reduce the voltage so the items becomes less shock giving. Welder use very high current and very low voltage may be 6o volts so that they do not get unnecessary shock.
- Q:When I unplug the power cord from my laptop the screen brightness automatically dims down to about 10% of its total brightness, and when I click the quot;increase screen brightnesskey on the keyboard the brightness will only increase about 5% until it stops. It's like I've put some limit as to how bright the screen can get. Anyone know how to fix this?
- This is standard on laptops. The display takes a lot of power so it is set to dim when there is no mains power. You can go to Control Panel, Power Options and change this. You will need to tell it that this isn't a laptop.
- Q:How can we make out the physical size of a power cable if the cable is said to be 4 core, 150 sq.mm ??? How will we measure the diameter of this cable ???? please suggest......
- A 4core (electrical) cable of that strength is usually built up from quarter circle shaped sectional wires. (Think of a pizza cut into four even pieces.) So, calculate the outside diameter from this point and add 4 times the insulator thickness. Example: 400V 4core cable has very likely 1mm insulator thickness. 150mm? * 4 cores is 600mm? total. By A=PI*d'*d'/4, d' being the diameter without insulator, would be d'=2*sqrt(A/PI)=600mm?/3.1415...=2*sqrt(...? Now, as said above, add the 4 insulator layers, and then you would be at approx. 31.7mm outside diameter.
- Q:what size of main power cable to use for two amps with combined power of 600 watts rms.the length of the run will be about 12 feet from battery to amplifiers.
- you can do this 2 ways have a 1/0 gauge wire running from your battery to a distrubtuin block that can branch off into 2 more wires, 4 gauge or 6/8.. and have each wire running to an amp or the same exact thing, except with a 4g wire from the battery to a splitter dist. block running into 2 8g wires.. but i would go with the first way.. will allow better power flow and not have to pull as much from the electrical system... and make sure the in-line fuse is the same rating of all amp fuses together.. so say each amp is a 30a fuse in each make sure the in-line fuse is at least 60amps
- Q:Does anyone with an Xbox 360 or someone that knows stuff about AC power cords tell me if the Belkin Standard Power Cable can be used with the xbox 360?Best answer gets 5.
- Yep its the same thing as the 1 that came with the Xbox 360 but not made by Microsoft. Only problem is you'll still need the power block that came with the xbox 360.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Rubber Insulated Ship Power Cable power transmission
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords