• Rebar Galvanized Tie Wire System 1
  • Rebar Galvanized Tie Wire System 2
  • Rebar Galvanized Tie Wire System 3
Rebar Galvanized Tie Wire

Rebar Galvanized Tie Wire

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

BLACK ANNEALED WIRE
Black annealed wire is made of high-quality iron wire, mainly used as tie wire or binding wire in construc

BLACK ANNEALED WIRE
Black annealed wire is made of high-quality iron wire, mainly used as tie wire or binding wire in construction work.
We produce the annealed wire with high-quality low carbon raw materials through wire drawing, anneal process. Its soft and has good stretching resistance. The finished products are smeared with slushing oil. So they are not apt to rust. We can tie up the products according to customers requirements, ranged from1 to 50 kg each bundle. And we can also make the annealed wire into U type carbon steel wire, straight cut wire etc. It is mainly used as tie wire or binding wire in construction.
Standard specification: Wire diameter from 0. 229mm-4. 19mm
Packing: Generally inner plastic and outer flax, of course, we can also pack according to our customers' requirements.

Material:carbon steel wire

Surface:  Black annealed soft wire without oil

Diamter:  16ga,16.5ga,17ga,18ga

Tensile strength:30--50kgs/mm2

Packing:  3.5lbs,3.125lbs,2.5lbs or 3lbs

              16 coils or 20 coils per carton

              24 cartons or 36 cartons or 48 cartons per pallet

              13 pallets or 20 pallets or 24 pallets per 20'GP

Black annealed rebar tie wire is made of iron wire, mainly used as tie wire or binding wire in construction. We can produce annealed wire ranges from 16ga,16.5ga,17ga,18ga , customers orders are also acceptable.

Q:The t-stat comes with EIT module. that wires to the t-stat and the furnace. I'm having trouble with the module to furnace wiring.
from the thermostat you match 1,2,3 wires to the module, from the module to the furnace. - R to R (this is your 24V hot) W to W (furnace 24V input G to G (fan for cooling 24V input) Y to Y (cooling 24V input), there should also be another wire that connects with this that goes to the condensing unit C to C ( Common - must have this connected for IAQ to work) as with the Y, there should be another wire to connect to this that goes to the condensing unit. - maybe W2 to W2 if you have a 2 stage furnace, you'll know if you have a 2 stage furnace because the W2 connection on the furnace will be present. - maybe Y2, if you have 2-stage cooling. if you have a humidifier connect both wires from the humidifier selinoid valve to each of the HUM terminals.
Q:What Spark Plugs and Wires would optimize my MPG? 2000 Bonneville SSEI
any plugs + wires will help the mpg a bit if the plugs are gapped correctly before installation
Q:Consider a copper wire 1 mm in diameter providing the power needed to run an appliance drawing a 4.8 kW at 12 V. Assuming that no heat is radiated away from the wire while the current flows:A. What will the temperature of the wire be after the current has run for 1 second through the wire?B. What will the physical condition of the wire be at that time?(The wire was initially at 20 degrees C)
Assume the wire is 1 meter long. Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Cu 17.2e-9 Ω-m or 17.2e-6 ohm-mm R = (17.2e-6)(1000) / π(0.5)? = 0.022 ohms Appliance current is 4800/12 = 400 amps Power is I?R = 400? x .022 = 3520 watts. Problem, this power is at a level almost as high as that of the appliance. In other words, the wire is too thin to sustain that power level. .
Q:1994 crown vic but it seemed like only 3 or 4 wires matched up exactly and this one wire was way to short so i had to route it the best way i could the guy said it was the right set of wires but the car runs way better then it did just wondering should i change couple of wires around to make it fit or just leave it what does crossing the wires mean
doad ya evehh hard a' punctuation? GETCHA SUMM
Q:The house was built in the 50's. Two wires are coming up from the switch and two wires are coming down from the top of the wall. I do not see a third wire. I attached the wall light wires left wires to left wires and right wires to right wires and light stayed on, when I moved the switch it threw the breaker. So I used may combination and the switch would not make the light work. It appears one wire may be white and one black. Help please!
The wire coming down from the wall is probably the power line. The wire going to the switch is meant to switch the hot lead lead only. Check the wires on the switch. There is probably a black and white on the switch. You will want to hook the white wire coming from above to the white wire on the light. Hook the black wire coming from above to the black wire going to the switch. Hook the white wire coming from the switch to the black wire on the light. While you are at it take black electrical tape and tape both ends of the white wire that runs to the switch. This will indicate that it is a hot lead.
Q:I have a buffalo tools 2000 watt generator i have been rebuilding. I have searched for a wiring diagram to help but no luck at all my question is about the wires that come out of the section that generates electricity. Outside of all the resets and switches coming right out of the back of the section that creates electricity has 6 wires coming out. Four are hooked to two different plugs two in each plug one set is red the other blue and the last two wires are separate black wires i would think are negative/ground wires i am looking to know what the red wires and blue wires actually are dc/ac volt i imagine just would like to know for sure don't want to blow anything up and help even guesses will be greatly appreciated.
Only one way to know for sure, Run down to Harbor Freight Tools and purchase a 7 Function Digital Multimeter for $3.00 and test the wires for voltage and if they are grounds or leads.
Q:Phone wire outside was old is anybody done that, do it your self put a new wire on?, Just curious to know..
Outside wire would feed back to the telephone central office and will either be aerial wire, connected to poles, or buried. Either way it is not feasible for someone other than the telephone company to replace.
Q:currently I have 2 12woofers wired to a single amp with 2 gauge wiring. Will it make a noticable difference if I upgrade the wiring to 0 gauge?
No. Even if the wire is undersized there would have had to have been a LOT of voltage drop in the 2 awg compared to the 1/0 awg wire, AND the amp would have to be loosely regulated for there to be any significant improvement. If both of those things are true it's still not likely there'd be enough of a change to be audible.
Q:i have until November 24 to choose between a wire or plastic retainer for when i get my braces off.In your answer please say why you would choose a wire or plastic retainer.
PERMANENT (WIRE) OR REMOVABLE (PLASTIC)? ADVANTAGES TO WIRE: CAN'T EVER BE LOST/BROKEN ADVANTAGES TO PLASTIC: CAN BE EASILY REMOVED FOR FLOSSING ALL SAID, I'D CHOOSE WIRE - WORRY FREE MAINTENANCE AND IT'S INVISIBLE TO OTHERS
Q:Two wires are placed parallel to each other. What would be the effect of passinga) upward current through both wiresb) an upward current throgh one wire and a downward current through the other.Explain.
a) When the currents through both the wires are in the same direction, the magnetic field due to each midway between them, by right-hand thumb rule, will be in opposite directions. This will result in attraction between the wires. b) When the currents through both the wires are in the opposite directions, the magnetic field due to each midway between them, by right-hand thumb rule, will be in the same direction. This will result in respulsion between the wires.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords