Ceiling channel and drywall channel, made of high-quality Snowflakes Steel

Product Applications:

 

Product used for internal constructions gypsum drywall partition such as hotels, terminal building,

bus station, theatres, shopping malls, factories, office buildings, and etc.

 

Product used for internal constructions gypsum drywall partition such as hotels, terminal building,

bus station, theatres, shopping malls, factories, office buildings, and etc.

 

Product used for internal constructions gypsum drywall partition such as hotels, terminal building,

bus station, theatres, shopping malls, factories, office buildings, and etc.

 

Product Advantages:

 

1.Light,good strength,cauterization resistance and water resistance

2.Matching magnesium fire-proof board,gypsum board and many other wall and ceiling board

3.Moisure-proof ,shock-resistant,high-effcient and environmentally-friendly

4.Easy and fast for installation,time-saving

5. Prompt delivery, high quality ,competitive price and complete sets of styles

6.We can supply you the products based on your specific requirements

 

Main Product Features:

(1) Lightweight  and high strength: 3-4 kg/m2 (1/10 of half brick wall), with yield strength 400mpa.

(2) Environment-friendly : galvanized steel-no radiation, have no harm to our health and not pollute the environment.

(3) Products with fillisters : Setting some fillisters in both sides of the keels in a selective way, in order to strength the

keels' vertical points and intensity.

(4)  Various sizes of metal track and metal stud : we are able to manufacture German, Japan and Aus-American types etc..

We can meet your customized demands.

Product Specifications:

Track Roll Forming Machine Ud  Cd  Uw Cw Profiles

 Image

Q: I feel the self-tapping screws do not drill into the light steel keel Hand drill use method is not directly to the back of the tapping screw inserted into the drill drill and then fixed on the light steel keel ah?
Gypsum board with the screw is not an ordinary self-tapping screws, its name is "dry wall nail", its structure and material and ordinary tapping screws are different, hardness, small diameter, long teeth, these features are easy It is easier to drill into hard objects. Although the light steel keel is steel, but the wall thickness is limited, the use of hand drill or wind can be easily approved by dry wall nails drill through it. On the dry wall nails to use a special batch of head, also known as the cross head, hand drill to use it to dry wall nails.
Q: Ok, I need to know if they either prevent conduction, convection or radiation . I also need to know how they prevent these thermal energy transfer mechanisms (conduction,radiation and convection) from occuring.
Tall trees: If you have tall trees around your house, your house will be cooler because of the shade. The trees are blocking radiation from the sun, and to a lesser extent stopping convection to the air around the house by acting as a wind block. The air around your house removes heat through open, free convection. Polystyrene: The polystyrene panel itself has less conduction than other materials because it is less dense. Conduction is essentially shaking the atoms of the materials. Less dense things typically have less atoms to shake. (There are exceptions). But if you are talking about a dropped ceiling (with the panels haning from the real ceiling in the metal grid) as a whole system, there is more to it than that. Without the panels, you would lose heat to your roof (and the world outside) by convecting from your room to the ceiling, CONDUCTING through the ceiling, and convecting to the world outside. Your sandwich would be: Outside world Ceiling Room air But a dropped ceiling adds some more layers in there, most importantly a space of dead air, which is an excellent insulator - similar to a thermapane window. Your sandwich would become: Outside world Ceiling Dead (not moving) air between polystyrene panels Polystyrene panels Room air The extra layer in the sandwich helps. Polystyrene makes a good insulator, but it would still work if you dropped a ceiling with metal panels because of the dead air. In heat and mass transfer problems, it is critical that when you ask the question, you define what the system boundary is. My answer is long because I don't know what that is in your question. Hope it helps.
Q: Light steel keel how many meters long?
It depends on what you need the specifications and thickness, a little thick can be done about 10 meters, thin about 45 meters or so, can be ruled processing.
Q: Can you touch up drop ceiling tile with paint ? I don't want to remove a tile for a scratch or scuff.?
You sure can Just finished my recroom turned out GREAT. If your grid system is the same colour roll the whole cieling don,nt use to much presure on the roller, I used C.I.L. Problem solver it,s a primer but makes nice job of tile. Do,nt for get youe drop sheet have fun,
Q: 75 light steel keel wall below to do a guide wall?
No special requirements, and now generally do not do this wall, light steel keel directly to the ground.
Q: Home decoration with wood keel good or light steel keel good
Specifically to see what kind of top hanging, if it is pvc wood keel of course, if it is gypsum board, of course, light steel keel. Integrated ceiling.
Q: Can the hotel light steel keel wall be used with plastic threading pipe?
Can, but it is best to install the sound insulation board, this light steel keel is very easy to resonate, so the sound will not be very good, it is best to please sound insulation construction to decorate the sound insulation,
Q: 3.5 meters high, 4.2 meters long.
Each vertical interval of 25 cm each horizontal interval of 40 cm each. With 3.5 / .2 5 get 14. with 4.2 / .4 was 10.5,14 * 11 = 154 so side with 154 nails, both sides is 308.
Q: We have a t-bar ceiling (ceiling with removable acoustical tiles) in the kitchenette area. It's awful! It looks like were eating in an office! Are there more attractive removable panels we can buy somewhere? (it has to be removable because it's the only way to access the air conditioning unit). Any suggestions? Thanks!
get a light and bright fabric and staple it to the ceiling. use a solid or very simple pattern.
Q: Do not know who can tell me ah
Install the main keel 1) The main keel should hang on the boom. The main keel spacing 900 ~ 1000mm. The main keel is divided into light steel keel and T-shaped dragon bone. Light steel keel can be used UC50 keel and UC38 keel. The main keel should be parallel to the room to the long installation, at the same time should be From arch, arch height for the room span of 1/200 ~ 1/300. The cantilever section of the main keel should not be greater than 300mm, otherwise Should increase the boom. The main keel should be docked, and the butt joints of the adjacent keels should be staggered from each other. The main keel hangs well After the basic leveling. 2) Span greater than 15m above the ceiling, should be in the main keel, every 15m plus a large keel, and vertical main keel Welded firmly. 3) If there is a large modeling ceiling, the shape part of the application of angle or flat steel welded into a frame, and should be connected with the floor firmly. (6) install the keel Times keel clear keel and dark keel two. Dark keel ceiling: that is, when the installation panel cover the keel will be closed in the shed, in the The roof surface can not see the keel. Ming keel ceiling: the installation of the panel when the keel exposed under the cover panel, in the ceiling The surface can see the keel. The keel should be close to the main keel. Times keel spacing 300 ~ 600mm. Times the keel points T-shaped paint keel, T-shaped aluminum alloy keel, and a variety of strip buckle manufacturers with a dedicated keel. T-shaped galvanized When the sub-keel is fixed to the main keel, the ends of the keel shall be seated on the horizontal flange of the L-shaped keel On the bar buckle plate has a dedicated angle to do the keel. (7) cover panel installation Hanging roof cover panels commonly used plate with sound-absorbing mineral wool board, silicon calcium board, plastic plate, grille and a variety of Kouban, etc.