General of Packing Seal Clean Water Centrifugal Pump
IS single stage single suction centrifugal clean water pump
1. Application : industry and city draining and the farmland irrigation.
2. Media : clean water or similar to clean water liquid with the
3. Max temperature is 80°C
4. Max inlet pressure is 0.6MPa.
Type description of Packing Seal Clean Water Centrifugal Pump
IS100-65-200A
IS-single stage single suction centrifugal clean water pump
100-the inlet diameter(mm)
65-the outlet diameter(mm)
200-the nominal name of the impeller(mm)
A-A,B,C refer to the first, the second, the third trim after the impeller respectively.
Structure type Packing Seal Clean Water Centrifugal Pump
The IS single stage single suction centrifugal clean water pump is horizontal installation, the horizontal
axial inlet and upward radial outlet.The structure of the pump is cantilever.
It can take out the rotors parts without disassembling the inlet and outlet pipes when repairing.
The pump is connected by the common flexible coupling or length flexible coupling with motor.
The shaft sealing of the pump is soft packing sealing.
The pump is the single-row radial ball bearing, dilute oil lubricate.
The rotating direction of Packing Seal Clean Water Centrifugal Pump
Viewed from motor, the rotating direction of the pump is clockwise.
The main parts materials:
The materials of the flow parts are common gray casting iron.
Supply range:
Supply full set pump, motor, common foundation, coupling and the bottom valve, pressure back valve, sluice
FAQ of Packing Seal Clean Water Centrifugal Pump
How can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
Do you have self-priming pumps?
Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.
Is it really necessary to fit a bleed valve for the boxes?
It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.
- Q:Hello, I have a 1996 Cavalier and it's got a small coolant leak by the water pump so I figured I'd replace it. I called around a little bit and one quote was $250. I'm sord of handy and have a few hours on Saturday is it that hard? I heard it's just a few bolts? Thanks!!
- Look in a good auto repair manual like Chiltons. The library gets them, if you don't want to buy one. Make sure there aren't any special proceedures or cautions. Clean the area and examine it well to make sure of what actually is leaking. Commonly a worn out water pump will leak through a weephole in its shaft housing where the shaft seal is- or was. Pay attention to the lengths of the bolts and if they are different sizes, be sure they go back in the right place. If the engine needs to have air bled out when refilled with coolant, read up on how to do that and execute that correctly.
- Q:I live in a house that uses a pump to push water from a tank to the bathroom and kitchen. It has a sensor that detects if water is flowing and pushes it much harder. Recently, it has been pushing the water for a second or less then it completely stops for a while. It's like a pulse of water then nothing. Can anyone give me feedback on what is wrong here? Thank you.
- from okorder :Self-priming pump working principle is: the pump before you start in the pump shell filled with water (or) from the water in the pump housing.Start after high-speed rotating impeller flow to the vortex in the impeller, shell, then the entry form the vacuum, the inlet non-return door open, within the air into the pump suction tube and the impeller, to arrive at the outer edge.Self-priming pump is a self-priming centrifugal pump, it has compact structure, convenient operation, stable operation, easy maintenance, high efficiency, long service life, and have strong self-priming capacity, etc.Line does not need to install the bottom valve, only to ensure storage in pump body before work are quantitative liquid.Pump after the normal starting, impeller liquid of suction chamber and inlet line of air suction, and can completely mixed within the impeller, the function of centrifugal force, and liquid with gas to the vortex flow volume outside edge, the impeller has a certain thickness is formed on the outer edge of the white foam belt and high-speed rotating liquid ring.Gas-liquid mixture into the gas-liquid separation chamber through diffusion tube.At this time, due to the flow rate suddenly drops, lighter gas is separated from the mixture of liquid and gas through the pump body spit continues to rise.After degassing of liquid to liquid storage chamber, and the reflux hole again into the impeller, and impeller with inhalation of gases from the inlet line again mix, flow under the action of the high-speed rotating impeller and the impeller outer edge....As the process cycle, decreasing the air in the suction line, until all gas absorption, complete the self-priming process, pump put into normal operation. What you said phenomenon should be pipeline leak, which leads to the self-priming pump process is repeated.
- Q:My dad wants to buy a salt water pump for a tiny pool.I'm not sure if it's pointless for the size that the pool is, but it is 12x12x3Is it too small of a pool or are there salt water pumps meant for tiny pools that I could look at?A link to any would be nice. :)Thanks!
- salt okorder /
- Q:I am leaking antifreeze, but only when the car is sitting after it has been running for a while, and its quite frustrating..it's coming around where the hoses are, I just got the thermostat/thermostat housing replaced, and also the heater hose and it seems to be coming from the same general area AS those...My car doesn't leak all the time it seems, so I'm not sure what this could mean. It has not over heated, my ac isn't also working at all.I have taken it back to the mechanic two times in the last 2 days and they cannot determine it's having a leak or not..which is quite ridiculous!! It seems to them that they think I'm crazy or something, I just don't like to see antifreeze underneath my car, I mean who does? Does this sound like a water pump? Where exactly is the waterpump located?
- i think this might be work on how to check if the water pump is in bad condition, first run your car for about 20 min or 30 min until it became hot. then look at your water pump while your engine is still running. if you noticed that there's a steam rolling off then it needs to be change or replace. or if you see that there's a leak. what you need to do is to look at it while the engine is running. then you will know if it is in bad condition.
- Q:Sewage treatment plant design how many pumps should be selected, head how to calculate the maximum design flow is 833M3/h
- Maximum design flow of sewage treatment plant is 833m^3/h, water pump can choose 2 or three units, the flow rate is 1000m^3/h. The amount of information in the head according to the problem can not be determined.Sewage treatment plants, water plants and other pumps are the key equipment, usually 1~2 units standby. Therefore, to choose 2 or three units of the same type of pump, each pump flow should be able to meet the use requirements. General pump selection, the pump rated flow should be 1.1 times the design flow of sewage treatment plants, that is, 833x1.1=916 (m^3/h), round 1000 (m^3/h).Pump head should be based on the actual work lift h determined. When calculating the actual lift, we should not only consider the actual geometric elevation difference of the pump installation, but also consider the factors such as pipe water loss and elbow water loss. The rated lift of water pump must have a certain margin, generally choose 1.1h, h for the actual required lift.
- Q:Fire pump control cabinet installation distance, ground height should be how much?
- 30MC is fine. There are no definite rulesSome drawings of the introduction is explained, because the drainage of the water pump in the case of clogging, may be submerged into the water pump control cabinet, causing some unnecessary trouble
- Q:I have a 2000 Chevy Malibu with 123xxx miles on it. I notice coolant being leaked on the floor heavily and my car gets hot driving. It leaks when the car is on and stops when it is off. Could it be a water pump? What r the signs of a bad water pump?
- the water pump leaks
- Q:Do it yourself steps
- If you're go to attempt this buy a manual. You have take apart the entire front of the engine. Remove the timing belt, just to get to the water pump. The timing belt runs the water pump. It's not a job for someone who has to ask how to do this on answers. Get a professional mechanic. This is from a 35 yr vet. of the garage.
- Q:37KW how many contactors does the pump need to start directly?
- Direct start requires 250A contactor.Contactor is divided into AC contactor (voltage AC) and DC contactor (voltage DC). It is applied to power, power distribution and power consumption. Contactor broadly refers to the use of coils in industrial electricity that flow through the current to produce a magnetic field, so that the contacts are closed so as to control the load of the appliance.
- Q:they say a water pump going bad is supposed to weep out of that hole....Yet I see that a new water pump kit has two gaskettes.some o rings....is it likely that it can leak from these sources and still not come out the weep hole?They talk about berring that could go bad or seals gone bad...does this occure in the area that gets inserted into the engine( the turbine portion of the pump)if you had to guess..where is the most likely area for a water pump to fail...if seems like I have wetness off to the left( back toward the firewall) and less off to the right( front of the car)..more off the left..it is very subtile off the right.I don't see anything coming out of the weep hole..BUT the weephole is directly on top( dead center)and back towards the engine in this model. I have the car jacked up on the passengers side/next to the wheel wellso the fluid is most likely to flow backwards toward the drivers side.
- A water pump could have all the works above the water, pulling via suction and pushed via atmospheric rigidity to a optimal of roughly 33 ft. Or it could have the motor above water and the lifting mechanism below with an prolonged rod connecting (like an oil properly with the donkey engine on the outdoors), yet a gaggle of weight and friction. Or it truly is waterproofed and the motor and pump decreased down the drilled shaft on a plastic pipe with an electric cord jointly with and push the water up. The final is a submersable. further sump pumps and recirculating pumps the place the cord, motor, and pump are below the liquid.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Packing Seal Clean Water Centrifugal Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords