Mobile Lighting Tower Generator Set 2.8KW and 5.0KW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
1.360 °all-round lifting lighting.
According to the needs, each lamp head can be individually adjusted up and down, left and right at a large angle to achieve 360°omnidirectional lighting; and the lamp head plate can be evenly distributed in four different directions. If you need lighting in the same direction, you can turn the lamp panel in the opening direction within 250° according to the desired lighting angle and orientation, and use the cylinder as the axis to rotate 360° to the left and right. The overall lighting has both brightness and range Big.
2.Each lamp head can be controlled by wireless remote control within 50 meters.
Three-section telescopic gas rod is selected as the lifting adjustment method, and the high-light coverage radius can reach 35-55m. The wireless remote control can control the opening and closing of each lamp within 50 meters, and the electric or manual air pump can be used to quickly control the gas rod The rise and fall, air pressure expansion and contraction, automatic protection of air pressure when automatic rise and fall (4 sections of telescopic light pole can be customized).
3.Mains + fuel can be used alternately, long working hours.
The generator set can be used directly for power supply, or it can be connected to 220V mains for long time lighting; the generator set uses a large fuel tank, which can be continuously filled for a long time to work for a long time, and the Philips bulb has a long service life.
4.The bottom is equipped with steering wheels and rail wheels.
The structure is compact and the performance is stable. The bottom is equipped with steering wheels and rail wheels. It can run on uneven roads and rails to ensure normal operation in various harsh and climatic environments.
Name | Description | ZOP2000 | ZOP4000 |
Lamp | Working voltage | 220V | 220V |
Lamp power | 4X500W | 4X1000W | |
Luminous flux | 10000LM | 20000LM | |
Average lifespan | 2000H | 2000H | |
The telescopic cylinder | Min-height | 1.8M | 1.8M |
Max-height | 4.5M | 4.5M | |
Lift time | 30S | 30S | |
Generator set | Rated output voltage | 220V | 220V |
Rated output power | 2.8KW | 5.0KW | |
Engine model | 170F | 188F | |
Fule capacity | 12L | 12L | |
Frequency | 50HZ | 50HZ | |
Type | Single cylinder four stroke air cooling | ||
Weight | Lamp | 10KG | 10KG |
Generator | 47KG | 79KG | |
Total net weight | 57KG | 89KG |
Tips:
1. Before using the generator, please read the instructions carefully;
2. When using the new generator, please add proper amount of four-stroke motorcycle oil (the diesel generator uses diesel engine oil above CD level) before starting;
3. Please use the generator in a well-ventilated environment to avoid harmful gas poisoning;
4. No fuel should be added when the generator is running, please stop and cool for more than 3 minutes before injecting fuel.
- Q: How does a throttle actuator/control for a generator know to increase decrease throttle based on electrical current demand?I’m thinking of building a DC generator using a diesel engine and a PMAC motor but am confused as to how I will vary the engine speed automatically to meet the varying current demand. Thanks!
- eir if you sense the current load by a line resistance of perhaps 0.1 ohm, you can increase or decrease the RPM of the generator as the current rises and falls
- Q: I know in some cases Electric companies will buy energy from someone who's solar panel's/wind turbines are overproducing. I think the system's have to be properly grid tied, i.e. either installed by or inspected by someone from the power company. I know that they don't pay much, but if you had a diesel generator running on waste vegetable oil.like if you made an arrangement with a restaurant to pick up their waste oil for them, it would be nice to be able to do so on a regular basis instead of going to them every so often saying Hey, I ran out of oil, I need some more. I guess I'm specifically asking about AEP. (American Electric Power) I live in Findlay, Ohio. I was on their website but couldn't find the answer to this question. Thanks!
- I manage social media for AEP. You can find more information about installing generating equipment and connecting to AEP Ohio's distribution system here: bit.ly/1dqZvGl You also may want to check out our guide for systems that generate less than 50kW: bit.ly/1eXLHpR If you have more questions, contact our Distributed Generation Coodinator at dgcoordinatopr [at] aep dot com.
- Q: I read about it in an old Mother Earth news (1993?) The car was mainly powered by the gen. The batteries would only kick-in for hills, boost of power, etc. I am interested in this design, anyone know if it works well? Can I use a 480volt 3ph gen-set to power motor/Drive for more efficiency/power? I already know about the volt,prius,leaf.
- It would have only 13.32 hp.
- Q: How much power does the generator from the diesel need to produce in order to bring the train up to running speed?
- That all depends upon a number of things. First is the type of traction motor that is driving the wheels. Next is the weight of the entire load to be moved by the traction motors. Also is the grade the load is being moved upon. When a locomotive gets up to speed it might not be using many amps by the traction motors to maintain the speed. However, to start from a dead stop on flat track with a very heavy load it could run as high as 200 or more amps. Again, it also would depend upon the number of engines driving the number of generators driving the number of traction motors. A single locomotive might need to use more amps to get up to speed than a combination of locomotives hauling the same load. There are many variables to this question. Given a particular locomotive, types of traction motors, the load weight, it would be easier to calculate what would be needed in amperage. Everything depends upon all of these things. An engineer can burn up a traction motor(s) by exceeding the amount of amps maximum that the motor can handle. The generators don't care, nor do they figure into the problem. The diesels don't care either. They will just turn the generators faster with more RPM's, and the faster they run, the more the generators will produce, but will the traction motors handle what is given them?? It just depends .
- Q: Elec. bill is too high, so I wanna run 2HP swimming pool pump via generator. It's 240V. How big a generator do I need? Is diesel less to purchase than gas? Is diesel cheaper to run? Can I run the pool say 6 hrs a day on generator designed for emergency back-up?
- The fuel will cost several times more than electricity.
- Q: I was also wondering what you but in them for them to work (gas, electricity etc.)
- Well just like electricity entering your house from the power company, the power from The power from your gas generator is the same thing. How much you run the generator is the same as running your light Or treadmill. However since power from the company is more steady and subsides, it's cheaper to be on the grid than to generate your own electricity especially with today's high gas prices.
- Q: I want to calculate the Genset load of following 3 phase, 50 C/s, 400/ 440 volts electric motors coupled with Water pumps.60 HP x 4 Nos. + 100 HP x 3 Nos. + 225 HP x 3 Nos.What is the method for calculating the safest load for all these motors to run simultaneously.
- You are after capacity of the generator not load. You add up all the power required: 240 HP + 300 HP + 675 HP 1215 HP 1 HP 746 W Power required 906.39 kW You take this figure in consideration to choose your set allowing for efficiency and power factor.
- Q: Hi, this may be a stupid question but im a city slicker planning on campong and i want to buy a honda generator, What kind of fuel does it use? where do i get it? thanks.
- It will use the same gas as your car, oil will be in the bottom of the motor, have some one show you how to check the oil level. and where to put the gas, then how to start it, keep extra oil gas on hand, also what size are you getting ? it will depend on what your going to power, a 6,000 watt generator will cover a lot of small stuff, and will run for 5 to 6 hrs on a full tank of gas, don't for get to take a extension cord, and a plug strip,
- Q: I have been trying to research the specifics of utilidor functionality for nearly two weeks and have come up with hardly any information. What I'm wanting to know is, at certain access points of utilidors in artic areas, is there something above ground that powers the tunneling below like possibly a transformer or a generator? I know it seems unfeasible to have either one out in the open to be exposed to the elements but I still want to know. And also even if this isn't the case now, was it so when the tunnel systems were first made?
- Utilidors is an acronym for Utility Corridors. This may be a tunnel system that contains all the necessary utilities to support a community, business of some other area needing electric, gas, water, sewer, communications, etc. These are found both above and below ground level depending on environmental concerns, costs, etc. The generators and transformers used to supply various points along the corridor and may be located above or below ground depending on design. A UG designed transformer for instance could be used below ground. A generator needs to be driven by something, gas engine, turbine, diesel engine, etc. these may be located below ground but it will have to have an external exhaust port somewhere. Hope this helps, Newton1Law
- Q: I have two deisel engines and two tank feeds, how can I connect the genset (4KVA) . I am conerned when the engines are idling or even running they will start the genset. I do not want to put an extra tank.Thank you
- If your tank has another port on it for a fuel line that is where you hook up. If not go to the supply line at the tank and put in a T fitting and then a shut off valve for each engine. Run the supply line to the generator from that T. You will also need a return line from the generator that you can T into at the return line from the engine at the tank. Many people that convert from gas to diesels run into these same problems. Often a fitting is made up that is put in the fuel fill line to allow for the return line. The generator supply and return lines will be smaller then the engine fuel lines. Running the engines will not cause the generator to start.
Send your message to us
Mobile Lighting Tower Generator Set 2.8KW and 5.0KW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords