ISO Standard End Suction Centrifugal Water Pump for Firefighting
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
ISO Standard End Suction Centrifugal Water Pump for Firefighting
1.Bare Shaft End Suction Pump for Firefighting
End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.
End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.
2.Main Features of ISO Standard End Suction Centrifugal Water Pump for Firefighting
• very easy to be installed and maintained
•Back pull-out design
•Driven through flexible coupling
•Customized design is available, OEM and ODM are welcomed.
•Horizontally and vertically installation as different pipeline system
3.ISO Standard End Suction Centrifugal Water Pump for Firefighting Specification
Material | Cast iron |
Pump diameter | 350-1600mm |
Flow range | 1~200L/s |
Pressure range | 0.2~2.25MPa |
Motor power range | 1.5~200kW |
Inlet/outlet Diameter | DN50~DN200mm |
Casing | Cast Iron Standard, Ductile Iron, Stainless Steel Optional |
Impeller | Bronze Standard ,Cast Iron, Stainless Steel Optional |
Shaft | ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional |
Shaft Seal | Mechnical Seal, Gland Pakcing Optional |
Flow rate | 2-1100m3/h |
Head | 2-152m |
Speed | 1450 or 2900(50hz),1750 or 3500(60hz) |
Working Pressure | 1.6PMa or 2.0PMa |
4.Picture of ISO Standard End Suction Centrifugal Water Pump for Firefighting
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: Why should the pump be closed when the centrifugal pump is started?
- Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
- Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
- Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
- Q: Does vacuum pump oil belong to dangerous goods?
- Is the grease inside? How could it be dangerous goods? Absolutely not!
- Q: What does electromechanical vector pump mean?
- Commercial buildings: hotels, office buildings, department stores, large saunas, etc.Irrigation: such as parks, playgrounds, orchards, farms, etc.Manufacturing: such as manufacturing, washing equipment, food industry, factories and so on
- Q: Why should I pump the pump before starting the centrifugal pump?
- 1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
- Q: Why can the centrifugal pump hold down the pressure?
- Centrifugal pumps are vertical, horizontal, single-stage, multi-stage, single suction, double suction, self suction and other forms. Vertical centrifugal pump is referred to as submerged pump, molten salt pump and submerged pump. Centrifugal pumps use the impeller to rotate and cause centrifugal motion of the water to work.
- Q: Is the centrifugal pump large or small?
- Centrifugal pump, the smaller the better the cavitation.1, centrifugal pump cavitation less, anti cavitation performance is better, the pump cavitation is called the necessary cavitation margin or pump inlet dynamic pressure drop, the smaller the better. Generally speaking, the pump cavitation is the need for cavitation, the pump inlet pipe said effective cavitation margin, that is, the device cavitation margin. For a given pump, at a given speed and flow rate required NPSH is called pump necessary NPSH, also called NPSH, is required to achieve the performance parameters of the pump cavitation, the internal flow and the centrifugal pump is composed of pump head itself, its physical meaning is that liquid drop in pump inlet pressure part degree, is to guarantee the pump cavitation does not occur, with surplus energy exceeds the vaporization pressure head at the inlet of the pump unit weight of liquid. The cavitation must be independent of the device parameters. It is only related to the parameters of the inlet of the pump. These parameters are determined by the geometric parameters at a given speed and flow.
- Q: Is vane pump good or gear pump good?
- The main parts of a gear pump are gears that mesh with each other. The meshing driving gear and the driven gear are respectively arranged on two parallel rotating shafts. Because the gear teeth enter and exit the meshes, the volume of the teeth is changed, and the suction and discharge effect is formed.
- Q: The working principle of magnetic pump
- Magnetic pumpBy the pump magnetic pump, magnetic actuators, motors of three parts. The key components of magnetic actuator by the external magnetic rotor sleeve, inner magnetic rotor and non magnetic components. When the motor drives the outer magnetic rotor, the magnetic field can penetrate the air gap and non-magnetic material, driven by the inner magnetic rotor is connected with the impeller for synchronization the rotation, to achieve non-contact power transmission, the dynamic seal into static seal. As the shaft, the rotor is within a magnetic pump, isolated sets of completely closed to completely solve the problem of "run, run, drip, leak, remove the oil refining chemical industry flammable, explosive, toxic and harmful media through the pump seal leakage security risks, effectively ensure the health and safety of workers.
- Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
- The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Send your message to us
ISO Standard End Suction Centrifugal Water Pump for Firefighting
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords