The technical parameter of type XS pump:
Pump outlet diameter: Dn: 80~800mm
Capacity: Q: 22~11600m³/h
Head : H: 7~200mm
Temperature :T: -20°C~105°C(Type XS)
-60°C~200°C(Type XS—R)
Solid parameter: ≤80mg/L
Permissible pressure ≤2.5Mpa (Type Xs)
≤4Mpa (Type XS—R)Technical Advantage:
1. Type XS pumps work stably with less noise and vibration and can work at a lifting speed due to short support at both sides, thus they can be widely used.
2. The pipelines arrangement of type XS pump looks simple and beautiful due to inlet and outlet at a same center line.
3. The same rotor of type XS pumps can be operated at reverse direction to avoid damage to the pumps water hammer.
4. Unique design of type XS pumps working at high temperature using middle support to fasten the pump casing and using cooling seals oil lubrication bearing then pump suitable for working at 200℃ especially for supplying heated water to pipe net system.
5. Type XS pump casting parts can be vertically or horizontally mounted according to different working condition, with mechanical seals or packing seals.
6. Type XS pumps look beautiful with visible lines adopting industrially designing.
If you have any special requirement, please contact us without hesitation.No file download!
- Q: How to select metering pump head?
- In metering fluoride, we recommend the use of Viton, sealed PVC pump head. For most chlorination applications, it is better to use EPDM sealed NP (plexiglass) pump head. For hydrogen peroxide mixtures, only PTFE sealed PTFE pump head or stainless steel pump head can be used
- Q: Pump unloading in hydraulic transmission,
- Can be used for short-term shutdown, pump non-stopNo unloading, usually through the overflow valve back to the tank, high pressure, power, at this time insurable pressure, and so on
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
- Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
- There are many ways to change the variable pump flow: by changing the eccentricity to change the piston stroke length (radial piston pump, the frequency change principle) motor speed to adjust the flow (such as gear pump flow control principle).
- Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
- The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
- Q: Advantages and disadvantages of centrifugal pumps?
- Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- In a dead head will be relatively high, the main downstream equipment and pump, if a dead head high, so the design pressure of the pump needs downstream equipment will be relatively large, resulting in the cost increases, so close a better head lower dead point.
- Q: Why is the flow of the pump too small will occur cavitation phenomenon?
- Why is it easy to produce cavitation when the inlet flow of pump is lowered?This is because the main performance parameters such as the head, power and efficiency of the centrifugal pump are not fixed, but vary with the flow rate. The curve drawn on a coordinate paper is called the performance curve or characteristic curve of the centrifugal pump. What happens when the flow rate decreases? The disadvantage of throttling adjustment is that the pump flow is small, and the impeller is easy to cause cavitation
- Q: What is a feed pump?
- Feeding the role of the pump is to make the injection pump inlet pressure, increase the injection pump inlet pipe flow rate, in order to ensure high pressure water injection pump has sufficient supply.
- Q: Why can't the centrifugal pump pump the vacuum?
- Condition:The pump shell must be filled with liquid under certain installation height and running without leakage.What is the phenomenon of centrifugal pump? What harm does it have? How to eliminate?)