• Horizontal double-suction split case pump System 1
Horizontal double-suction split case pump

Horizontal double-suction split case pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
  • The technical parameter of type XS pump:

    Pump outlet diameter: Dn:  80~800mm

    Capacity: Q:  22~11600m³/h

    Head : H:  7~200mm
    Temperature :T:   -20°C~105°C(Type XS)
                                 -60°C~200°C(Type XS—R)
    Solid parameter:     ≤80mg/L
    Permissible pressure ≤2.5Mpa  (Type Xs)
                                 ≤4Mpa      (Type XS—R)

    Technical Advantage:

    1.       Type XS pumps work stably with less noise and vibration and can work at a lifting speed due to short support at both sides, thus they can be widely used.

    2.       The pipelines arrangement of type XS pump looks simple and beautiful due to inlet and outlet at a same center line.

    3.       The same rotor of type XS pumps can be operated at reverse direction to avoid damage to the pumps water hammer.

    4.       Unique design of type XS pumps working at high temperature using middle support to fasten the pump casing and using cooling seals oil lubrication bearing then pump suitable for working at 200℃ especially for supplying heated water to pipe net system.

    5.       Type XS pump casting parts can be vertically or horizontally mounted according to different working condition, with mechanical seals or packing seals.

    6.       Type XS pumps look beautiful with visible lines adopting industrially designing.

    If you have any special requirement, please contact us without hesitation.


Q: Fire pump and shower pump flow head selection, high resolution.
Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
Q: Pump unloading in hydraulic transmission,
Unloading water, from the literal interpretation is along the pump, leakage of water seal through the head, the water with certain pressure (even with relief effect seal). The water as the working quality is asked to be recycled, now the design of some use it as a water seal, and others by direct recovery, but eventually recovered.
Q: What does electromechanical vector pump mean?
Scope of application is;Residents living water: such as high-rise buildings, residential areas, villas and so onPublic places such as hospitals, schools, gymnasiums, golf courses, airports, etc
Q: What does "efficiency" mean in a water pump catalog?
The efficiency of the water pump nameplate refers to the maximum efficiency that the pump can reach at the rated speed
Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
Reciprocating pump is a positive displacement pump, the volume change of flow is the unit of time, constant flow speed constant, can not rely on increased resistance to change the flow resistance increase is only leaked, only small changes in flow.
Q: Why can't the centrifugal pump pump the vacuum?
Running process: depending on the centrifugal pressure of the liquid in the impeller, the liquid is sucked into the liquid, and the liquid in the pump shell has the conversion of the energy form, so that the fluid can obtain the mechanical energy mainly with the static pressure.The characteristics of the system: the suction diameter than out of large diameter, the general valve installed.
Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
Unreasonable, easy to produce throttling loss, pressure loss, pressure reduction, easy to cause cavitation
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Q: Attention should be paid to the use of pumps?
7 water pump and pipe interface must be sealed, because if there is debris access, then the pump will cause damage to the interior. 8 for the water pump bearing is also the focus of inspection, use up to check whether the bearings wear,
Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area