Horizontal Corrosive Chemical Centrifugal Liquid Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of Horizontal Corrosive Chemical Centrifugal Liquid Pump• Industrial chemical pump
• For corrosion liquid
• Easy maintenance,High efficiency
• OEM order is accepted
• Good quality and service
2.Main features of Horizontal Corrosive Chemical Centrifugal Liquid Pump
Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.
Iron and steel industry: electroplating, pickling, etc;
Paper-making industry: agents, bleaching liquid, sewage, etc;
3.Specification of Horizontal Corrosive Chemical Centrifugal Liquid Pump
Model | Capacity | Head | Speed | NPSHr | Efficiency | Power(N)(kW) | Weight | |
Q(m3/h) | H (m) | n(rpm) | r(m) | η (%) | Shaft power | Motor power | w(Kg) | |
IH50-32-125 | 7.5 | 22 | 2900 | 2 | 47 | 0.96 | 2.2 | 34 |
12.5 | 20 | 2 | 60 | 1.13 | ||||
15 | 18.5 | 2.5 | 60 | 1.26 | ||||
IH50-32-125A | 6.7 | 17.5 | 2900 | 2 | 45 | 0.71 | 1.5 | 33 |
11.2 | 16 | 2 | 58 | 0.84 | ||||
13.5 | 14.7 | 2.5 | 58 | 0.93 | ||||
IH50-32-160 | 7.5 | 34.3 | 2900 | 2 | 44 | 1.59 | 3 | 39 |
12.5 | 32 | 2 | 54 | 2.02 | ||||
15 | 29.6 | 2.5 | 56 | 2.16 | ||||
IH50-32-160A | 7 | 30 | 2900 | 2 | 42 | 1.36 | 2.2 | 38 |
11.7 | 28 | 2 | 52 | 1.71 | ||||
14 | 26 | 2.5 | 54 | 1.83 | ||||
IH50-32-160B | 6 | 25.8 | 2900 | 2 | 40 | 1.05 | 1.5 | 37 |
10 | 23 | 2 | 50 | 1.25 | ||||
12 | 21 | 2.5 | 52 | 1.32 | ||||
IH50-32-200 | 7.5 | 52.5 | 2900 | 2 | 38 | 2.82 | 5.5 | 43 |
12.5 | 50 | 2 | 48 | 3.54 | ||||
15 | 48 | 2.5 | 51 | 3.95 | ||||
IH50-32-200A | 7 | 45.3 | 2900 | 2 | 37 | 2.33 | 4 | 42 |
11.7 | 44 | 2 | 46 | 3.05 | ||||
14 | 41.5 | 2.5 | 49.5 | 3.2 | ||||
IH50-32-200B | 6.5 | 39.6 | 2900 | 2 | 36 | 1.95 | 3 | 41 |
10.8 | 37.5 | 2 | 45.5 | 2.42 | ||||
13 | 36 | 2.5 | 48.5 | 2.63 | ||||
IH50-32-250 | 7.5 | 82 | 2900 | 2 | 28.5 | 5.87 | 11 | 75 |
12.5 | 80 | 2 | 38 | 7.16 | ||||
15 | 78.5 | 2.5 | 41 | 7.83 | ||||
IH50-32-250A | 7 | 72 | 2900 | 2 | 28 | 4.9 | 7.5 | 74 |
11.7 | 70 | 2 | 37.5 | 5.95 | ||||
14 | 68.5 | 2.5 | 40 | 6.53 | ||||
IH50-32-250B | 6 | 61.5 | 2900 | 2 | 27.5 | 3.65 | 5.5 | 73 |
10 | 60 | 2 | 36.5 | 4.48 | ||||
12 | 58.5 | 2.5 | 39 | 4.9 |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: How does the centrifugal pump pump and cut the pump?
- Check the motor, pump and fasteners in good condition; whether the lubricant is added or not;Disc dynamic coupling, whether or not stuck phenomenon;Open the inlet valve, remove the gas in the pump or pump the gas out of the pump;
- Q: Water pump outlet valve sequence
- In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
- Q: Double floor sewage pump circuit diagram of a small problem
- Q 2, SA and SS are select switches, and different positions indicate the same difference between the two nodes. SA hits the left position 13, 14 to connect, hits to the right position 21, 22 to connect. SS hit the middle position, 5 and 6 turn on, 7 and 8 turn on; hit the right position; 1 and 2 turn on; 11 and 12 turn on; hit the left seat; 9 and 10 turn on; 3, 4 turn on.
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- The dead point head is the measured head after the outlet valve is closed. Mainly on the lower reaches of the pump equipment, such as your dead center, the lift is 300 meters, that is, 3MPa
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: Is the sewage pump the same as the mud pump?
- No. the main functions are different:1, pump two main performance parameters is the displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement
- Q: Types and differences of pumps
- Classification and working principle of pump by structureClassification of pumpsInvolved pump standard product types are also very much, a centrifugal pump, metering pump, screw pump, reciprocating pump, hydraulic pump, submersible pump, oil pump, water pump, pressure test pump, vortex pump, cryogenic pump, vacuum pump, roots pump, molecular pump, gear pump, mud pump, corrosion-resistant pump deep well pump, water pump, mixed flow pump, axial flow pump, boiler feedwater pump, liquid pump, injection pump, chemical pump, pump plugging and no leakage pump, plastic pump, fire pump and so on, there are many. Its name is divided according to some conventional classification methods such as pump vane pump volume, pump etc., some are divided by purpose such as sewage pump, pump and other health, some names are more random as diffusion pump, liquid nitrogen pump. As long as the production of this product, with standard requirements, through a certain application and approval procedures may produce a new The standard, but sometimes the content also has a repeated cross, quite. The domestic and foreign standards, the domestic standard is more than the number of foreign standards. In general, such as centrifugal pumps are widely used, the production history of the pump more standard (total standard centrifugal pump up to more than 100). As new standard pump leakage pump this rapid development is relatively small. This paper introduces the structure and working principle of the pump according to the classification of the
- Q: Do you have a suction pump higher than 9 meters?
- Pump rated suction generally 7 meters or so, it is estimated that no one calibration pump suction stroke 9 meters. Calibration suction range of 9 meters is not reliable.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
- Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Send your message to us
Horizontal Corrosive Chemical Centrifugal Liquid Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords