• Horizontal Corrosive Chemical Centrifugal Liquid Pump System 1
  • Horizontal Corrosive Chemical Centrifugal Liquid Pump System 2
  • Horizontal Corrosive Chemical Centrifugal Liquid Pump System 3
Horizontal Corrosive Chemical Centrifugal Liquid Pump

Horizontal Corrosive Chemical Centrifugal Liquid Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Specifications of  Horizontal Corrosive Chemical Centrifugal Liquid Pump

• Industrial chemical  pump

For corrosion liquid

Easy maintenance,High efficiency

OEM order is accepted

Good quality and service

2.Main features of  Horizontal Corrosive Chemical Centrifugal Liquid Pump

  • Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.

  • Iron and steel industry: electroplating, pickling, etc;

  • Paper-making industry: agents, bleaching liquid, sewage, etc;

     

3.Specification of Horizontal Corrosive Chemical Centrifugal Liquid Pump

 

 

ModelCapacityHeadSpeedNPSHrEfficiencyPower(N)(kW)Weight
Q(m3/h)H (m)n(rpm)r(m)η (%)Shaft powerMotor powerw(Kg)
IH50-32-1257.52229002470.962.234
12.5202601.13
1518.52.5601.26
IH50-32-125A6.717.529002450.711.533
11.2162580.84
13.514.72.5580.93
IH50-32-1607.534.329002441.59339
12.5322542.02
1529.62.5562.16
IH50-32-160A73029002421.362.238
11.7282521.71
14262.5541.83
IH50-32-160B625.829002401.051.537
10232501.25
12212.5521.32
IH50-32-2007.552.529002382.825.543
12.5502483.54
15482.5513.95
IH50-32-200A745.329002372.33442
11.7442463.05
1441.52.549.53.2
IH50-32-200B6.539.629002361.95341
10.837.5245.52.42
13362.548.52.63
IH50-32-2507.5822900228.55.871175
12.5802387.16
1578.52.5417.83
IH50-32-250A77229002284.97.574
11.770237.55.95
1468.52.5406.53
IH50-32-250B661.52900227.53.655.573
1060236.54.48
1258.52.5394.9

 

4.FAQ

 

 What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

 Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

 What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

Q:If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,
Q:What is the lift of diaphragm pump?
Diaphragm pump lift is different from the centrifugal pump, refers to the diaphragm pump can raise the height of water, the unit is meters water column. Lift depends on the size of the outlet pressure, the pressure per kilogram is equivalent to 10 meters height
Q:If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
First of all, the performance curve of the centrifugal pump is similar to the track of the train, and the train can not run away from the track.Secondly, the performance curves of centrifugal pump mainly include flow head curve, efficiency flow curve, power flow curve. When the pump is ready, the curve is fixed. In practical application, after determining the flow rate, the corresponding lift head, efficiency and power (relative to density) are determined. General requirements for centrifugal pump operating in the vicinity at the highest point of efficiency, the efficiency of the flow curve is similar to parabola, so if the actual operation condition deviated from the rated point, whether large or small, will cause the decline in pump efficiency (generally rated value is less than 15%), increased operating costs.
Q:Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q:What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
Q:Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.
Q:The main factors affecting the performance of centrifugal pumps
Revolutions required to have. It has the following meanings: 1, similar to the geometry of centrifugal pump, everywhere efficiency at the top of the similar condition; centrifugal pump 2, than the number of different, its geometry must be different than the number; the same pump, its shape is similar, but does not rule out the shape similar situation. The following factors are related to specific speed. The specific speed of centrifugal pump has nothing to do with the nature of the conveying fluid, but has a close relationship with the shape of the impeller and the performance curve of the pump. The pump with high specific speed corresponds to the highest efficiency when the flow rate is large and the head is small
Q:Working principle and diagram of axial piston pump with pressure compensation variable
Adjust the flow characteristics, the first limit screw to the top, according to the flow and pressure changes in the required range, adjusting the spring set, the initial flow pressure began to change to meet the requirements, then the limit screw to the ultimate pressure when the flow is no longer changed, the relationship between flow and pressure the changes are determined by the pump itself.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords