Horizontal Corrosive Chemical Centrifugal Liquid Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of Horizontal Corrosive Chemical Centrifugal Liquid Pump• Industrial chemical pump
• For corrosion liquid
• Easy maintenance,High efficiency
• OEM order is accepted
• Good quality and service
2.Main features of Horizontal Corrosive Chemical Centrifugal Liquid Pump
Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.
Iron and steel industry: electroplating, pickling, etc;
Paper-making industry: agents, bleaching liquid, sewage, etc;
3.Specification of Horizontal Corrosive Chemical Centrifugal Liquid Pump
Model | Capacity | Head | Speed | NPSHr | Efficiency | Power(N)(kW) | Weight | |
Q(m3/h) | H (m) | n(rpm) | r(m) | η (%) | Shaft power | Motor power | w(Kg) | |
IH50-32-125 | 7.5 | 22 | 2900 | 2 | 47 | 0.96 | 2.2 | 34 |
12.5 | 20 | 2 | 60 | 1.13 | ||||
15 | 18.5 | 2.5 | 60 | 1.26 | ||||
IH50-32-125A | 6.7 | 17.5 | 2900 | 2 | 45 | 0.71 | 1.5 | 33 |
11.2 | 16 | 2 | 58 | 0.84 | ||||
13.5 | 14.7 | 2.5 | 58 | 0.93 | ||||
IH50-32-160 | 7.5 | 34.3 | 2900 | 2 | 44 | 1.59 | 3 | 39 |
12.5 | 32 | 2 | 54 | 2.02 | ||||
15 | 29.6 | 2.5 | 56 | 2.16 | ||||
IH50-32-160A | 7 | 30 | 2900 | 2 | 42 | 1.36 | 2.2 | 38 |
11.7 | 28 | 2 | 52 | 1.71 | ||||
14 | 26 | 2.5 | 54 | 1.83 | ||||
IH50-32-160B | 6 | 25.8 | 2900 | 2 | 40 | 1.05 | 1.5 | 37 |
10 | 23 | 2 | 50 | 1.25 | ||||
12 | 21 | 2.5 | 52 | 1.32 | ||||
IH50-32-200 | 7.5 | 52.5 | 2900 | 2 | 38 | 2.82 | 5.5 | 43 |
12.5 | 50 | 2 | 48 | 3.54 | ||||
15 | 48 | 2.5 | 51 | 3.95 | ||||
IH50-32-200A | 7 | 45.3 | 2900 | 2 | 37 | 2.33 | 4 | 42 |
11.7 | 44 | 2 | 46 | 3.05 | ||||
14 | 41.5 | 2.5 | 49.5 | 3.2 | ||||
IH50-32-200B | 6.5 | 39.6 | 2900 | 2 | 36 | 1.95 | 3 | 41 |
10.8 | 37.5 | 2 | 45.5 | 2.42 | ||||
13 | 36 | 2.5 | 48.5 | 2.63 | ||||
IH50-32-250 | 7.5 | 82 | 2900 | 2 | 28.5 | 5.87 | 11 | 75 |
12.5 | 80 | 2 | 38 | 7.16 | ||||
15 | 78.5 | 2.5 | 41 | 7.83 | ||||
IH50-32-250A | 7 | 72 | 2900 | 2 | 28 | 4.9 | 7.5 | 74 |
11.7 | 70 | 2 | 37.5 | 5.95 | ||||
14 | 68.5 | 2.5 | 40 | 6.53 | ||||
IH50-32-250B | 6 | 61.5 | 2900 | 2 | 27.5 | 3.65 | 5.5 | 73 |
10 | 60 | 2 | 36.5 | 4.48 | ||||
12 | 58.5 | 2.5 | 39 | 4.9 |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- In operation, the main gas extraction limit vacuum is achieved by the main pump, so we call it the main pump, which plays the main role of the pumpThe front pump is the pump that needs to be opened ahead of the main pump. It is called the pump before the main pump and the pump running the main pumpIf you don't understand, look at your signature and ask again
- Q: How about the depreciation of vacuum pumps?
- (a) housing and buildings for 20 years;(two) aircraft, trains, ships, machinery, machinery and other production equipment for 10 years;
- Q: What is the minimum continuous flow of a pump?
- Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
- Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
- Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
- Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
- (4) before installation, make sure all pipes connected with the pump should be clean, and no solid foreign bodies which may cause damage to the pump shall be allowed.(5) apply the blind flange or other things to the suction, exhaust or open pump to ensure that no sundries enter the pump cavity during the installation.(6) check whether the pump random data is complete and complete; whether the pump surface has obvious damage. Only with complete data, no obvious damage to the pump, you can continue to install.(7) the installation of centrifugal pump with the coupling of the hand when turning slowly rotating coupling or pulley, observe the pump rotation are stable, flexible and adjustable, the rotor parts have no jamming, the pump has no debris crash, bearing the operation is normal, with elastic suitability.
- Q: How is the pump level of submersible sewage pump determined?
- Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
- Q: What is the difference between centrifugal pump and rotary vane pump? What are the distinctive characteristics or principles of rotary and centrifugal? O (a _ U) O thank you!
- Directly said vane pump on the line, generally do not say rotary vane pump.The centrifugal pump is divided according to the direction of the liquid flow in the impeller
- Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 7., master the knowledge of concrete mix ratio, strictly forbid to add water to the pump at will.8., concrete mixing and workability, gravel diameter is too large, effectively refuse to pump.9. when the delivery pump fails, it can analyze the cause and quickly eliminate the trouble.10. pump complete, you must clean the pump body and pressure pipe residual.11. complete other temporary work assigned by the leader.
- Q: Working principle and structure of external gear pump
- The principle of the gear pump, gear pump structure consists of two gear mesh together with each other, and composed of pumps known as gear pumps. It relies on the gear teeth meshing space change in volume to transport the liquid, it belongs to the rotary pump, also can be considered as a volume pump. There are many kinds of gear pumps. According to the meshing mode, it can be divided into external gear pump and internal gear pump. According to the tooth shape of gear, it can be divided into positive gear pump, helical gear pump and herringbone gear pump.
- Q: What is a feed pump?
- In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
Send your message to us
Horizontal Corrosive Chemical Centrifugal Liquid Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords