• Eelctro Galvanized Steel Wire For Binding System 1
Eelctro Galvanized Steel Wire For Binding

Eelctro Galvanized Steel Wire For Binding

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Commercial Galvanised Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Q:Broken dryer, 4 bladed wire, Old dryer available to me, has a 3 wire cord, can I swap the cords?
the guidelines basically recently replaced interior the previous couple of years requiring new properties to be geared up with the 4 prong recepticals rather than the three prong recepticals for 220 V merchants. in the experience that your dryer is fantastically new, interior the final 4 years or so... the twine that is hooked as much because it now could have the skill to be interchanged with a 4 prong twine by basically buyingh a 4 prong twine and screwing the eylets to the surprising connections at the back of your dryer. in the experience that your twine won't be able to be switched out, then i'd pass backward and replace the 4 prong container with a three prong container. i'd do it this sort so as that one and all your electric connections are interior a receptical, rather of having 220 Volt wires basically twine nuted at the same time.ok good success.
Q:I wired an outdoor lamp-post. I tested it before wiring it to the fuse box...and if I touch the lamp-post I feel the current (a slight shock). I will be using a ground fault breaker....so I assume if I wire it to that I am going to loose the connection. Any thoughts on what is wrong?
In addition to the answer Paul gave, check the wiring that the white wire is the neutral or common wire and that it goes to the shell side of the lamp holder. A few years ago, I had a similar problem, when all of the checks were made, the panel was wired with the black wires on the neutral buss. Hence all of the devices were wired backwards. Call a qualified professional electrician to do the work.
Q:I currently have a ceiling fan wired to a dimmer wall switch that controls the fan and the light, not good I know. I would like to set up the dimmer switch where it controls the light only and then i can use the fan pull switch for the fan. but i am not sure how to wire this with my current wires. In the wall box where the dimmer switch is I have two sets of wires coming from two different locations. one set has a black, red, white, and green. the other location has black, white and copper. currently the green and copper are connected and capped, the two whites are connected together and capped, two blacks are and connected to the black wire coming from the dimmer and the red is connected to the other black wire from the dimmer. how would I wire the dimmer switch to only control the light and not the fan? I want to make sure i do this safely.any assistance is greatly appreciated.
enable me initiate out by making use of asserting that the cord's popping out of the ceiling bypass like this, Black cord is alway the warm cord the White cord is often the common floor cord the bare cord is the earth floor cord. if there's a purple cord popping out of the ceiling it is so which you would be able to turn the mild off at extra then one change . i'm uncertain what a hunter fan is ,yet what ever you do do no longer hook the black (warm) cord with the WHITE (floor) cord, in case you probably did try this ,you will could reset your breaker , it form of seems such as you may have 2 purple cord popping out of the ceiling , in case you do you may hook them to the Black / White cord, it is so which you would be able to paintings the mild from the two change.
Q:In the ceiling is one black, one white and a ground. How do I connect a new ceiling fan to these two wires? The ceiling fan has black wire, white wire, a blue wire and a green wire. We don't have green in the ceiling nor do we have a ground...knob and tube perhaps? So, can we connect this fan or not?Thanks!
Personally, I would not connect anything to old knob-n-tube wiring. I would replace all of it with modern wiring. And as for a ceiling fan, not only does it require a box designed for ceiling fan support (which I doubt you have right now), it also requires 3 wires, served by a 14/3 Romex with ground. It will have a black, white, red, and bare ground. The red wire is for the light, black for the fan, white neutral, and bare copper to green ground. On the wall, you will need a double-gang box containing 2 devices. One is a standard light switch controlling the light. The other is a fan controller unit ($12.49 at Home Depot) for the fan speed. It has 4 click-stops, High, Medium, Low, and Off. It uses a standard double-switch wallplate. On the fan itself, cut the chains off. Be sure the fan is set to HIGH, and the light ON when you cut them.
Q:I just installed a Unity Spotlight on my 2007 Chevy Impala. There's a 6 inch wire coming out of the handle. When I stripped the wire there is a few strands of copper wire. How do I wire up the light? There isn't a distinct positive or negative.
I okorder /... check out literature for others, if this don't help.
Q:Okay so my question is how would I wire these in a ported box with 2 terminals on each side of the box? Also, is the quot;Bridged Wirefeatured in the diagram negative speaker wire? Thanks.
It's a misnomer to use the term bridged in wiring subs. They should call it a jumper wire, or something similar. It's a minor detail, but it leads to novices thinking bridging is something done with subs -- it's not, it's the amp. Although since mono amps are becoming more and more common bridging is becoming a thing of the past as mono amps aren't bridgeable. The way I would do it would be to wire each sub to its respective terminal with the coils in series for 4 ohms.
Q:Who sells just 4 gauge power and ground wire so I can do the big 3 upgrade?
You okorder /... It's also available with black insulation and in 2 gauge. Parts Express also sells appropriate ring terminals.
Q:i recently replaced my spark plug wires on my 97' lincoln continental. i was wondering if i should get plug wire shielding for them also......thanx
If it needed wire shielding it would have come with it from the factory. If you get OEM style plug wires then it will come with shielding as well, hence OEM, if not then it didn't come with them and doesn't need them.
Q:If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm.What is the tension in both wires?
The tension in both wires.? If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm. What is the tension in both wires? In the triangle ABC, AB(c) = 100 cm, BC (a) = 50 cm and AC (b) = 75 cm 2s = a+b+c = 225 cm s = 112.5 s-a = 112.5 - 50 = 62.5 s-b = 112.5 - 75 = 37.5 s-c = 112.5 - 100 = 12.5 tan A/2 = √ {(s-b)*(s-c) / [s*(s-a)] = √ {37.5*12.5) / [112.5*62.5] A = 28.95? tan B/2 = √ {(s-c)*(s-a) / [s*(s-b)] = √ {12.5*62.5) / [112.5*37.5] B = 46.57? C = 180-28.95-46.57 =104.48? --------------------------------------... 46.57? is the angle between horizontal and 50 cm wire. 28.95 is he angle between horizontal and 100 cm P is the tension in the 50 cm wire and Q is the tension in the 75 cm wire Equating the horizontal components of the tensions P cos 46.57? = Q cos 28.95 ? P = Q cos 28.95 ?/ cos 46.57? P = 1.27 Q-------------------1 Equating the sum of the vertical components of the tensions to the weight of the pot P sin 46.57? + Q sin 28.95 = 8*9.8 N 0.73P + 0.48 Q = 78.4N 0.73(1.27 Q) + 0.48 Q = 78.4N Q = 55.72 N and P = 70.76 N ============================= Or use Lamis theorm Angle between P and Q = 104.48? Angle between P and the pot = 90 + 46.57? Angle between Q and the pot = 90 + 28.95 By Lamis theorm P/ cos 46.57? = 78.4/ sin 104.48? P = 55.67 N and Q = (78.4/ sin 104.48? ) cos28.95 = 70.85N ====================================
Q:I am buying my sister Interior Underdash lights for her car, but it says it requires a quot;hard wire installationbecause it does not come with an on and off switch. What exactly does that mean? Will the lights turn on and off according to whether the car is on or off? Also, what is a hard wire installation?
Hard wire means it's not just plugged in. eg. using the cigarette lighter but instead is permanently wired in. All you need to do is wire the lights ground wire to any ground wire under the dash eg. ignition ground or radio ground ( wire will be black ) or directly to a screw that goes into any metal part of the chassis and wire the lights positive wire to either the accessory wire from your ignition (lights come on when car is on) or a constant power wire eg. radio power wire and wire in a toggle switch so you can turn the lights on or off at will.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords