• Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire System 1
  • Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire System 2
  • Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire System 3
Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
8000 kg
Supply Capability:
3000000 kg/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Structure of Galvanized Iron Wire Description

Galvanized Iron Wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc. 

Galvanized Iron Wire mainly used in construction, express way fencing, binding of flowers and wire mesh weaving. Galvanized iron wire according to manufacturing technique, it includes hot-dipped galvanized iron wire and electro galvanized iron wire. Mainly telecommunication equipment and materials, medical equipment and device, weaving of wire mesh, steel rope, and filtration mesh, high-pressure pipe, construction, arts and crafts, etc

 

2.Main Features of Galvanized Iron Wire

• Durable

• Good Visual

• Convenient

• Use widely

• Antirust

• Versatile

 

3. Galvanized Iron Wire Images

 

Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

 

4. Galvanized Iron Wire Specification

 Galvanized Iron Wire/Electro Galvanized Iron Wire/hot-dipped galvanized iron wire

 

5.FAQ

We have organized several common questions for our clientsmay help you sincerely

 

How about your company

One of the most biggest manufacturer & supplier of wires and wire meshis a large-scale professional Galvanized Iron Wire factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements.

 

What is the different use of Hot-dipped and Electro Galvanized Iron Wire ?

1)Hot dipped galvanized iron wire can be supplied in the form of coil wire, spool wire or further processed into straightened cut wire or U type wire. Galvanized iron wire is made of Low carbon steel wire Q195.

Hot dip galvanized iron wire, hot dip galvanized wire, hot-dip galvanized wire

2)Electro galvanized iron wire applications:
Electro galvanized iron wire is mainly used in construction, express way fencing, binding of flowers and wire mesh weaving.
Electro galvanized iron wire, electro galvanized steel wire, electro galvanized Wire. 

 

How long can we receive the product after purchase?

In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.

 

Q:2 long striaght wires (20m each) ,each having a 1.0A current going up.The distance between the two wires is 1.0m(a) what is the magnetic field (magnitude and direction) at a point o.50m left of the wire 1?(b)what is the magnetic field (magnitude and direction) at a point 0.6m right of Wire 1?
Assuming Wire 2 is to the right of Wire 1: a) Bwire1 = (u*I)/(2*pi*r) = ((4*pi*10^-7)*1A)/(2*pi*0.5) = 0.000004 Bwire2 = 0.000000424 Btotal = 0.000004424 (away from wire 1) b) Bwire1 = 0.000003333 Bwire2 = 0.000005 Btotal = -0.0000017 (toward Wire 1)
Q:I'm doing a science experiment and I don't know why resistance decreases as the diameter of the wire increases. Any help is appreciated.
Basically a thick wire behaves as a lot of thin wires. Comparing one thin wire to a whole bunch, it is easy to see a difference. How this is explained in simple terms is that there are more paths for the electrons to take in a thicker wire, instead of them all being forced though the same space in the thin wire. You could compare it to cars on a motorway, the more lanes there are the more cars will be able to travel on it. A single lane would get blocked up if all cars in say four lanes tried to travel down it. Hope that explained things clearly!
Q:I need a wiring guide or diagram for the stereo of a 2005 ford taurus. somethig that will show which wires are for front and rear speakers, and the remote start wire
Hope this helps you out bro Car Radio Battery Constant 12v+ Wire: Green/Black Car Radio Accessory Switched 12v+ Wire: Black/Pink Car Radio Ground Wire: Black/Green Left Front Speaker Positive Wire (+): Orange/Green Left Front Speaker Negative Wire (-): Blue/White Right Front Speaker Positive Wire (+): Tan/Green Right Front Speaker Negative Wire (-): Green/Orange Left Rear Speaker Positive Wire (+): Gray/Blue Left Rear Speaker Negative Wire (-): Brown/Yellow Right Rear Speaker Positive Wire (+): Black/Violet Right Rear Speaker Negative Wire (-): Orange/Violet
Q:A thin wire connected to a light bulb will have the bulb shine dimmer than a thicker wire. What is the scientific reasoning for this?
Thin wires are usually used to make heat because there is more resistance going through a thin wire. In an incandesent bulb 60% OF THE OUTPUT IS HEAT. If thee is thicker wire, more electrons go through and the light can be brighter.
Q:Ceiling fan has Green, Blue, black and white and the ceiling only has a black wire and white wire.
Do what Elaine said above. If there is not a light, don't use the blue wire. If there isn't a green wire or bare wire in your box, attach the fan's green wire to the electrical box itself (if its metal.).
Q:If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm.What is the tension in both wires?
The tension in both wires.? If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm. What is the tension in both wires? In the triangle ABC, AB(c) = 100 cm, BC (a) = 50 cm and AC (b) = 75 cm 2s = a+b+c = 225 cm s = 112.5 s-a = 112.5 - 50 = 62.5 s-b = 112.5 - 75 = 37.5 s-c = 112.5 - 100 = 12.5 tan A/2 = √ {(s-b)*(s-c) / [s*(s-a)] = √ {37.5*12.5) / [112.5*62.5] A = 28.95? tan B/2 = √ {(s-c)*(s-a) / [s*(s-b)] = √ {12.5*62.5) / [112.5*37.5] B = 46.57? C = 180-28.95-46.57 =104.48? --------------------------------------... 46.57? is the angle between horizontal and 50 cm wire. 28.95 is he angle between horizontal and 100 cm P is the tension in the 50 cm wire and Q is the tension in the 75 cm wire Equating the horizontal components of the tensions P cos 46.57? = Q cos 28.95 ? P = Q cos 28.95 ?/ cos 46.57? P = 1.27 Q-------------------1 Equating the sum of the vertical components of the tensions to the weight of the pot P sin 46.57? + Q sin 28.95 = 8*9.8 N 0.73P + 0.48 Q = 78.4N 0.73(1.27 Q) + 0.48 Q = 78.4N Q = 55.72 N and P = 70.76 N ============================= Or use Lamis theorm Angle between P and Q = 104.48? Angle between P and the pot = 90 + 46.57? Angle between Q and the pot = 90 + 28.95 By Lamis theorm P/ cos 46.57? = 78.4/ sin 104.48? P = 55.67 N and Q = (78.4/ sin 104.48? ) cos28.95 = 70.85N ====================================
Q:I have DirectWay and have a wireless router. I recently hardwired my computer in because I kept losing signal. The distance between my computer and the router is about 30 ft. But since I hardwired my computer in, it seems slower than when I ran the wireless adapter, i.e downloading videos and music. I was under the impression that wired was faster. What gives????
wired or wireless, you are capable of downloading way faster than whatever the cap is on your internet service
Q:I removed my old door chime/bell a few years ago and replaced it with a wireless one. That one quit working and now I am attempting to install a new wired one again. The only problem is, when I removed my old one way back, I failed to label the existing wires to where they go. I have two wires coming out of my wall mount, one white, one brown and the both have a white and red wire sticking out of them. I am not sure which one/ones will connect to the FRONT and TRANS posts on my new chime. I don't have a rear door bell button so that is not a problem. Which wire goes to the FRONT and TRANS and do I cap off any of the 4 wires? My installation instructions don't cover the mindless mistake of not having the wires labled.
If your old transformer is still working connecting the wires up wrong will burn it out in an instant. I have been there. The safest thing to do is locate your transformer and disconnect all the wires. Take the doorbell off and disconnect the wires. And then you have the chime off as well. Then use a continuity tester (has a battery and lights up or buzzes when the circuit is complete) and find out which wire goes where. You might have to string a temporary wire through the house to complete the circuit from downstairs to upstairs. Once you know which wire goes where you will be connecting a wire from one end of the transformer to the button a line from the button to the chime and a line from the chime to the transformer (a series circuit.) A voltmeter will tell you if the transformer is already burnt out. If you get a new transformer make sure you get one that matches the voltage requirement of the chimes (usually 16 volts.)
Q:What are the basic characteristics of wire resistance strain gages?
A resistor that is not to be changed is called a fixed resistor. Variable resistance is called a potentiometer or variable resistor. The ideal resistor is linear, i.e., the instantaneous current through the resistor is directly proportional to the applied instantaneous voltage. Variable resistor for partial pressure. One or two removable metal contacts are tightly pressed on exposed resistors. The contact position determines the resistance between any end of the resistor and the contact point.
Q:i am putting in a ceiling fan. there is a black wire and a white wire along with a copper looking wire in the wall. on the fan there is a blue,white,and green. where do i connect this to the wires in the wall? running from a wall switch btw
connect the fan black wire and the fan blue wire to the house black wire. then connect the white fan wire to the white house wire. connect the short green wire from the fan and fan bracket to the copper wire. the blue is the power wire to the light on the fan. Good luck...

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords