Corrosion protection armoured computer cable

Corrosion protection armoured computer cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000meters m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Corrosion protection armoured computer cable

Product introduction:

The product is low capacitance, low inductance, distributed type instrument signal cable of perfect shield and anti-interference performance, it can reliably transmit feeble analog signal and digital signal, and its explosion-proof safety is prominently better than general DCS cable and control cable. The product is widely used to transmit auto-control signals in the places where exist explosion danger such as chemical, power, coal gas engineering and mine, etc, or other places where require higher explosion-proof safety.

Executive Standard

  Q/AHXYLY02-2009 equivalent to British standard BS5308

Operational Performances

1. Rated AC voltage: U0/U 300/500V

2. Max. working temperature of conductor core: 70°C, 105°Cand 135°C

3. Lowest ambient temperature: for fixed laying:-40°C,non-fixed laying:-20°C

4. Allowed minimum bending radius of cable: for non-armored cable, not less than 6 times of cable outer diameter; for copper tape shield or annoyed cable, not less than 12 times of cable outer diameter.

Main Technical Data

Item

Unit

Data

Working capacitance

PF/m

≤80

Capacitance unbalance

PF/m

≤1

Distributed inductance

µH/m

≤0.6

Inductance/resistance

µH/Ω

≤25

Induction voltage (interference magnetic field 400A/m)

mV

≤5

Static induction voltage (static voltage 20kV)

V

≤1

Radiation field penetration (interference field 200MHz, 120dB)

dB

≤66

Insulation resistance at 20°C

MΩ.km

≥5000

Test voltage

V/1min

2000

Flame-retardant character (test to be performed in terms of GB/T12666.5-1990)

Type A

Basic Types and Descriptions

Type

Designation

IAJYPVP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS cable

IAJYPVRP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP1VP1

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield, intrinsically safe DCS cable

IAJYP1VRP1  

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP2VP2

Copper-core PE insulated, PVC sheathed, copper tape separate shield and general shield, intrinsically safe DCS cable

IAJYP3VRP3

Copper-core PE insulated, PVC sheathed, aluminum/plastic compound tape separate shield and general shield, intrinsically safe DCS flexible cable

IAJYP1VRP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, intrinsically safe DCS flexible cable

IAJYP1V22RP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, steel tape armored intrinsically safe DCS flexible cable

IAJYP1V32PR

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and woven copper wire general shield, small-gauge steel wire armored intrinsically safe DCS flexible cable    

ZR-IAJYPVP

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYPVRP

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP1VP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYP1VRP1

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP2VRP2

Copper-core PE insulated, 105°Cflame-retardant sheathed,copper tape separate shield and general shield, intrinsically safe DCS flexible cable

ZR135- IAJYPVRP3

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield, aluminum/plastic compound general shield, intrinsically safe DCS flexible cable

ZR-IAJYPV22RP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield, tinning copper wire general shield, steel tape armored intrinsically safe DCS flexible cable  

ZR135- IAJYP1V32RP

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning copper wire separate shield, woven copper wire general shield, small-gauge steel tape annoyed intrinsically safe DCS flexible cable

1.Code and definition

Item

Code

Definition

Flame-retardant

character

/

ZR

ZR-135

Non flame-retardant that can be omitted

General flame-retardant

135°C flame-retardant

Series code

IAJ

Intrinsically safe explosion-proof DCS cable

Insulation material

Y

V

VD

E      

PE

PVC

Low smoke and low halogen PVC  

Low smoke and halogen-free polyolefin

Shield material

P

P1

P2

P3

Woven copper wire shield

Tinning copper wire

Copper tape

Aluminum/plastic compound tape

Armor material

22

32

Steel tape armor

Small-gauge steel wire armor

Heat-resistant grade

70

105

135

Max.working temperature is 70°C,can be omitted

Max.working temperature is 105°C

Max.working temperature is 135°C

Conductor type

A

B

R

Single-strand conductor

7-strand twisted conductor (type A&B are marked after specification)

Multiple-strand flexible conductor

Specification

Pairs (or groups) x cores of each pair(or group) x conductor core section mm2

Pairs (or groups): 1,2,3. .. .24

Core of each pair (or group): 2, 3

Conductor core section s: 0.5, 0.75, 1.0, 1.25, 1.5, 2.5 (mm2)

Note: Intrinsically safe cable required to be high-temperature-resistant, oil-resistant and acid/alkali corrosion-resistant, its types and materials can be referred to relevant items of computer cable. Based on the above-described type description for intrinsically safe explosion-proof DCS cable, different combinations can be selected to meet requirements.

SpecificationSize

1.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3, ZR-IAJYP2VP2(Twin type)

Cont table


Note: The outer diameter of armored cable could add 4.0mm

2.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3,ZR-IAJYP2VP2(Triplet)


Cont table


Note: The outer diameter of armored cable could add 4.0mm

FAQ

Marking Examples:

Example 1: Intrinsically safe DCS flexible cable selectingcopper-core PE insulation, PVC sheath, woven copper wirepair shield and general shield, nominal section of conductorcore is 1.0mm2, 19-strand twisted conductor with three 3-wire groups, can be expressed by:IAJYPVRP 3 x 3 x 1.0

Example 2: Intrinsically safe DCS cable selecting copper-core PE insulation. 105°Cflame-retardant PVC sheath.aluminum/plastic compound pair shield, woven copper wire general shield, nominal section of conductor core is 1.5mm2, 2pairs: Conductor-core applies single-strand copper wire: ZR-IAJYP3VP-105 2 x 2 x 1.5(A)

Conductor-core applies 7-strand twisted wire:

ZR-IAJYP3VP-105 2 x 2 x 1.5(B)

Packaging & Shipping

 

Packaging Detail:

international wooden drums or according to your   requirement.

Delivery Detail:

In 15days or as the quantity   you required


Our Services

1.Free samples can be afford if needed.

2.2 years warranty after selling


Company Information






Q:So I had this monitor I used to use, then didn't use it for a while, now I want to use it again but can't find the power supply cable. I can get a new one, but the thing is I have to know what to ask for, right? I don't know what cable to ask for. I did some google search on it too but still can't seem to find exactly the type of the cable that is specified. Help? Can someone do it for me so I can go to my local electronics score and look for a cable that will do the work?
unerversal 3 prong power chord for pc
Q:I ordered this recently only to find that it was just the HDD, no cords whatsoever. I've never had to buy cables for an HDD before, and I'm especially not used to SATA (I didn't make the jump from IDE to SATA until this year.)
it is a sata and takes the Standard power connector on the back like the regular drive and the the rest the other guy covered you can tell the difference it's not a ribbon cable looks like romex almost and the ends are polarized one end looks like this L____ and this end is reversed the cable can't be plugged in wrong just like IDE hard drives.
Q:I need the cable for my TV to be longer. It uses a 10A 125W cable, and all I can find (at a price I like) are 13/15A cords. Is it okay to use this in conjunction with the 10A TV power cable? It will be plugged into a surge protector if that makes a difference...
The 10 amp and 13 amp ratings are just the maximum amount of current those cables are made for. Your TV will only use 2 or 3 amps, so both cables are fine.
Q:What is the meaning of the cable 3 * 1 * 0.8?
The power industry mainly includes electricity industry and power plants and other power cables industry is the power industry to do the cable and cable should belong to the power industry but does not belong to the system within the power system only includes the State Grid China Southern Power Grid five nuclear power plants and other large state-owned enterprises
Q:Hi, I bought a geforce gtx 660 ti and with it came 2 X 6 pin PCI express power cables. Problem is I only have 2 connectors in my computer, so one cable is useless. Will 2 Athena Power Model CABLE-YPHD 8Molex Y Splitted Power Cables allow me to use both the PCI cables? Thanks.
Hi There, Both ports need to be connected for power for the card and if that is the case then two feeds from the power supply would need to be used. This would be because one power feed with the Y connector probably would have too much load on the one single feed and it would overheat and could cause a big problem. To be absolutely sure you should refer to the instruction manual for exactly what is needed. If still unsure a call to the manufacturer should sort things out. By the way this video card requires a 450 watt (or larger) power supply to operate properly. I would buy a proper power supply for this powerfull video card. This card needs 400 watts if overclocked so I would go for a power supply of about 600 watts (or larger) with feeds for each power adapter for the video card. Hope this helps, Al
Q:What is a PVC Power Cable and what is its application?
PVC Power cable : Polyvinyl coated power cable. this kind of cable can be used in domestic appliance, machines and outdoors, it's quite durable.
Q:I have been looking all over the internet for one of the previously stated cords, and I just can't seem to find one. I really don't know much about power cords, but a monitor a friend gave me needs a 12V, 4.0A DC power cable.I would prefer to use a site like newegg, OKorder or cables unlimited (or a large retailer like Walmart).
If the pin fits, and the tolerance on the 12V is comparable, the better amperage should not be a controversy. in case you have a voltage meter, you are able to verify the 12V adaptor for its output.
Q:What does the cable (YJV-5 * 6) mean?
Full name: cable ZR-YJV22-4 * 16MM2ZR: flame retardant ----- YJV22: copper conductor cross-linked polyethylene insulated PVC sheathed double steel belt wrapped armored power cable --- 4 * 16MM2: 4 core, each core 16 square millimeters.
Q:I want to install a Bazooka Powered Sub (EL84-HP) to my car. I currently have a Pioneer 4-channel 600-watt amp that has a direct power line from the battery. However, I do not want to run another power line from my battery to my Bazooka sub, which has it's own built-in 100-watt sub. Would it be OK to connect the power cable only from my Pioneer amp to my Bazooka sub?
It's not necessarily the best way to do it, but it will certainly work, provided that the power wire running to the Pioneer amp is thick enough to adequately supply both amplifiers. Usually a 100-watt Bazooka tube doesn't require all that much current. Don't daisy-chain the ground wire, though; ground the Bazooka amp separately.
Q:Can anyone help? my pc wont turn on without them hooked up.
If you look very close the position for these connectors is written on the motherboard along side of the pins that they connect to in very small letters.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords