• Aluminum Foil Asbestos Roofing Insulation System 1
Aluminum Foil Asbestos Roofing Insulation

Aluminum Foil Asbestos Roofing Insulation

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

This is a new environmentally friendly aluminum foil bubble heat insulation material, which is soft, light and easy to install. It is made from aluminum foil and polyethylene through special machinery.

Function:

Can be installed on roof, wall or floor, resist over 80% external heat from buildings, protect wall, resist thermal shock and sudden cold, etc.

Characteristics:

1.No odor and toxicity, environmentally- friendly;

2.Moisture barrier, sun-proof, waterproof, good sealing property, heat preservation, energy saving…

3.Heat reflection, heat insulation, sound insulation, anti-radiation, anti-vibration, and shielding;

4.Light, soft, dust free, fire retardant, easy to install;

5.Summer: moisture barrier, sun-proof, heat insulation, saving energy consumed by cool air conditioning ;

6.Winter: heat preservation, central heating saving, and remarkable energy-saving effect.

Product: fireproof material

Technical parameters:

Material structure: AL/bubble/AL

Bubble size: ¢10mm, H 4mm

Bubble weight: 0.13 KG/M2

Roll size: 1.2M W*40M L (can be customized)

PROPERTIES

Test Data

Unit

Thickness

3.5

MM

Weight

256

G/M2

Emissivity

0.115

COEF.

Thermal conductivity

0.034

W/M0

Apparent Density

85

KG/M3

Reflectivity

95-96

%

Water Vapour Transmission

0.013

G/M2 KPA

Corrosion

Doesn't generate


Tensile strength (MD)

16.98

Mpa

Tensile strength (TD)

16.5

Mpa


Usage:
1. Roof, wall, floor;
2. Shells of air conditioner and water heater;
3. Protective coatings of water pipe and ventilating pip



Q: or in queensland
Depends on whether you are employed or working contract. Currently it could be 18-25 per hr for employee or upto 40 per hr for contract depending on allowances and if you are providing your own vehicle or company vehicle. Then are you doing bats or anticon, it is usually charged on a sqm rate. Call some roofing companies or insulation companies and ask them what their rates are.
Q: i am going to insulate my conservatory roof its poly carbon and dirt has got inside so cant clean what can i use its a semi flat roof i thought about using insulation board silver backed your comments will be gratefull
The owners of the federal deserve are the biggest criminals. Research woodrow Wilson 1913-signed Americas banks over to a group of a few dominant men. A few years later in 1919 Woodrow Wilson apologized for destroying our country.
Q: I am specifically considering the re-roofing of a an older home where rafters were made with 2x4 or 2x6 and the rafter space (and possibly the attic space) does not allow sufficient space for insulation and proper ventilation behind the insulation. The old layers of roofing have to be removed in any event. At this point I am considering applying insulation boards on the existing sheathing and then a new layer of sheathing before the new roofing material. (similar to a SIP: structural insulated panel) The two issues I am concerned with is that the insulation can act as a vapor barrier. Would condensation potentially rot the lower sheathing. How is this avoided in SIP roofing panels? The second issue may be with fire regulations.
The sip panels are vented depending on what thickness over all that you want. The last ones I used had 4 inches of rigid foam board then on top of that had 3" strips every 16" an inch thick which created an airspace. On top was 5/8 Osb. To create an affective air flow the fascia cannot plane through with the plywood at the bottom but fall just short of the 1" space. To cap it a oversized vented drip edge is used. You must also have a ridge vent for proper flow. These panels can near 100$. You can do it your own way like I do when building log cabins by laying 2" foam down first then lay 2x4 16 on center on top then finally your plywood. If you use CDX instead of Osb it will outlast it by 100%. Rigid foam insulation is not like batt-faced. Rfboard ins. Is used in boat hulls and even after being submerged for long periods of time will return to its original density and r-value. For obvious reasons batt ins. Will not. You won't have a moisture problem as long as you don't have a venting problem. If you are using high hat lighting don't let the cans touch your rigid ins. Tuck batt in softly around them TAKE THE PAPER OFF! By code if you have an interior wall 10or more ft. It must have a fireblock, simply a 2x4 turned flat between the studs. On your roof the ceiling you see inside, (most likely 7/8 tongue and groove boards) passes as the same. Good luck!
Q: do i leave air gap in attic roof for insulation?
The best way to set up an attic is to put a vapor barrier under the rafters (before nailing on the gyproc), then put the insulation (fibreglas batts) between the rafters to full depth (10 or 12 inches). Soffit vents are installed under the eaves at the sides of the roof, and gable vents are placed near the peak of the roof at the ends. This allows for airflow resulting from convection, particularly important in the summer months to remove heat buildup in the attic. If the insulation is adequate, it will not only isolate this heat buildup from the inside of the house in summer, but will prevent heat loss to the attic in winter. (The airflow in winter will be minimal, but will remove any moisture/condensation that might collect otherwise.)
Q: My new room is an addition to a mobile home, and has a single-layer metal roof. I have 3 "main" concerns. What are the cheapest and/or most effective ways of eliminating them?1. No heat insulation- cold air sinks from the roof to my room, and my warm air rises to the roof and cools.2. Condensation forms on the inside and drips occasionally. My computer, bike, and downhill boards are in here!3. It seems like bugs could easily get into my room, but that's just a suspicion.
You really need a correct "building paper" under the iron. It is aluminum with a tar sandwiched between...You can also use plastic sheeting as a vapor barrier..
Q: should thermal insulation ever be applied directly to the underside of a roof top?
Should it be done, No. Thermal Insulation is put direftly above the ceiling. Not on the actually roof top. The reason being, that even though both methods will trap in heat, With the insulation on the arches of the roof, it still allowing heat into the Attic, Or roof space. This means that the top of the roof will infact be the warmest part of the house, and lot of heat will be lost. from the main rooms of the house.
Q: Without loft insulation ,the roof space is full of air.Why does this not keep the heat in?
Because air can circulate, (it's called convection) and transfer a lot of heat. In other words, air alone is a very poor insulator. .
Q: I've found lots of building forums and general "building advice" columns that go over very high-level pros/cons to choosing roofing material and insulation options, but I want a site where I can see hard costs of ordering each of the materials so I don't have to call up a ton of contractors or dealers. Does such a comparison site exist? Everyone offers quotes, but that takes too much time to apply for quotes to every dealer.I'm specifically interested in knowing what green options I can afford (cotton batting vs. formaldehyde-free fiberglass, etc.).
You could call ABC supply or Norandex Reynolds, they are the biggest distributors I know of. They may have some resources for you.
Q: I would like to know which direction the one side with foil faces. The roof or the interior of the room?This is an attic room. Roof being "raw" i mean that it looks like cedar tongue in groove boards...then shingles on top of them. Which way do i face the foil side of the sheet..?thanx
The foil side should go to the outside. I believe it's a moisture barrier.
Q: We bought a house and put new metal roof on over the shingles. (first please don't say, this or that should have been done, just what I can do now) Any how, we have put a lot of money into the house, roof, all new electrical, all new plumbing, etc., I had to make the house in a "living in condition" with a low budget. ............ the house does not have insulation in ceilings, this has to be done next summer. (budget) Any how, the metal roof has condensation under it, only in the ridge vent area. This drips a little and I need to fix it. Now, I know that insulation wouldprobablyy fix this, but we don't have the money right now, so I need help on what to do? Is there anything that with a $100 to $200 budget can be done? I have searched a little, and maybe use a "spray-on"insulation help? The area is where the gap is at the peak and where themetall overlaps the ridge vent. (I thinkthat'ss what it's called)Thank you! :)
The problem might be resolved by venting the attic. You need to have an air exchange in the attic to prevent condensation.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords