Al / Cu Conductor , Control cable/Aerial, Mining cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
LV&MV, Al/Cu Conductor, Insulation/Sheath PVC/PE/XLPE, Shield CTS/, Armour SWA/DSTA/ATA, Power/ABC/ACSR/Control/Overhead cable
Power cable
1. Material: Cooper, Aluminum
2. Rated voltage: low and medium voltage
3. Wire identification: Red, yellow, blue, white, black
4. No. Of cores : Single core cable: from 1.5 mm2 to 800 mm2; Multi-core cable: from 1.5 mm2 to 400 mm2
5. Standard: Low voltage: IEC60502-1 Medium voltage :IEC60502-2 or other requirement.
6. Insulation: PVC, XLPE, PE
7. Sheath:PVC, PE, XLPE
8. Armor: Galvanized steel wires armouror Galvanized steel tape armour Aluminium Tape Armour/ Aluminium Wire Armour.
9. Application: Suitable for indoor, channel, conduit,underground,vertical well etc.
10. Nominal cross section area: from 1.5 mm2 to 800 mm2.
Aerial Bundle Cable Service Drop
1. 3x35+54.6+16 3x50+54.6+16 3x70+54.6+16 3x95+70+16 3x120+70+16 3x150+70+16 mm2
2.2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2
3. Standard: ASTM ANSI, ICEA S-76-474, NFC 33-209 or other request.
Overhead electrical stranded cable (Bare Conductor)
1.Material: 1) Aluminum stranded wire and aluminum alloy stranded wire 2) Overhead stranded galvanized steel wire 3) Aluminum clad steel
2. Type: AAC, AAAC, ACSR, ACAR.
3. Standard: AAC: GB/T 1179-2008 IEC 61089 ASTM B232 BS 215 part1, DIN 48201-5 or other requirement.
AAAC:GB/T 1179-2008, IEC 61089, ASTM B 399 BS3242, DIN 48201-6 or other request.
ACSR : GB/T 1179-2008, IEC 61089, DIN48204, ASTM B232, BS215 PART 2or other request.
4.Application: These cables most widely used aerial line in aerial electric transmission lines and main product to form a power grid.
Aerial Insulated Cable
1. Material: Aluminium, copper
2. Type: LJ, LGJ, LGJF, JL, JLHA, JL/G, JLHA/G, JL/LHA, JL/LB, JLHA/LB, JG, JLB.
3. Rated Voltage: 0./1 kV, 10kV, 35kV.
4. No. of cores: 1, 2, 3, 4, 3+k(A), 3+k(B).
5. Standard: GB/T12527 GB/T14049 or other.
6. Insulation: PVC, PE, xlpe
7. Sheath:PVC, PE, XLPE
8. Application: applying in cable fixed aerial laying or used as wire leading into user's premises.
9. Nominal cross section area: from 10 mm2 to 710mm2.
Control Cable
1.Material: Cooper
2.Rated voltage: 300/500V, 450/750V, 0.6/1 kV.
3.No. Of cores : 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
4.Standard: GB/T9330, IEC or customers' requirement.
5.Insulation: PVC, XLPE, PE
6.Sheath:PVC, PE, XLPE
7.Armor: Steel wire, Steel tape
8.Application: Suitable for chambers, tunnels and ducts, light-current control system and heavy-current magnetic interference region etc.
9.Nominal cross section area: 0.5~10mm²
PVC Insulated Electric Wires & Cables
1.Material: Annealed copper wires, bunched(class 5); Solid copper wire(class
2.Rated voltage: 300/500v and 450/750v
3.Wire identification: Red, yellow, blue, white, black
4.No. Of cores : single core, 2 cores,3 cores,4 cores, 5 cores
5.Standard: IEC 60227 or according to customers' requirement.
6.Insulation / Sheath : PVC
7.Application: Fixed wiring, house wire, building etc.
8.Nominal cross section area: from 0.25 to 240.
- Q:One day, all of a sudden my amp stopped working. I inspected the battery terminal and noticed their was corrosion on both terminals, cleaned it off, and I inspected the fuse in my positive wire for my amp and noticed the fuse was blown, replaced it and the amp would still not power on, I reinspected the fuse again and it had already blown, I replaced it once more and it did the same thing.
- some were in your system the power wire running the amp is hitting ,ground and blowing the fuse,or your amp is crapped out.are the fuses in the amplifier blowing too.i would hook up another power to to amplifier out in the open and see if your having the same problem.if you do its the amplifier if its all good re run another power wire.with a distribution block and go bigger with the wire size,and you can down size the wire from the distribution block to the amplifier.hope this helps.
- Q:Wire and cable manufacturing process (to be detailed)?
- Copper core per square of the safe current (continuous use) for the 2.5A, intermittent use of 4A, according to the power count 550W-880W.
- Q:I ordered this recently only to find that it was just the HDD, no cords whatsoever. I've never had to buy cables for an HDD before, and I'm especially not used to SATA (I didn't make the jump from IDE to SATA until this year.)
- it is a sata and takes the Standard power connector on the back like the regular drive and the the rest the other guy covered you can tell the difference it's not a ribbon cable looks like romex almost and the ends are polarized one end looks like this L____ and this end is reversed the cable can't be plugged in wrong just like IDE hard drives.
- Q:I have a VOX Valvetronix amp and my idiot older brother has misplaced the the power cord to it. Where is the best place to find said replacement as well as a guitar jack to plug into the amp itself since that seems to be missing as well. Thanks!
- Vox Ad30vt Amp
- Q:ok i have somehow lost my power cable that goes from the outlet to the power block of the older version of the xbox 360 and is it possible that i can use an extension cord or something in place of that since i have lost it or do i need to get a whole new cord in all? yes this may sound stupid but i need some help on this one, thanks:)
- Well I don't know of any extension chord that could replace this fairly crucial component . I think you should look for another one with a friend that maybe has a broken xbox or an old pc.. You might find the piece you're looking for on another machine like a computer or a printer . Look around and see , good luck ;)
- Q:I have a SATA hard drive and a SATA cd drive. Is the power supplied through the SATA cable or do i need seporate power cables
- there is a sata power cable that u need to plug in, it comes from ur power supply and is a lil different than the normal power cable .
- Q:I have my Clearwire modem but have lost the power cable. Does anyone know what I would look for in a replacement power cable.
- check the Clearwire URL .. Support tab
- Q:in the specs it says the power supply doesn't have a pci-e connector?Does that mean i cant use the video card, or is there a way I dont know? Please help.Thank you very much
- Okay, right off the bat I see a problem with that power supply. Aside from not having a pci-e connection it states it doesn't work with SLI or Crossfire (i.e. Nvidia or ATI). Since you're wanting to get a GeForce card, which works with a mobo with an Nvidia chipset, you'd need a more up-to-date power supply. Second - that card uses 18 amps on the 12-volt rail, and according to the specs on that power supply it runs up to 16 or 17 amps, so the power supply you're looking at isn't powerful enough to support the card. My advice - first make sure your mobo has an Nvidia Chipset. Second, spend a bit more and get a better power supply, and check the voltage - you need at least 18 amps on the 12-volt for that card.
- Q:on the end of the cable that connects to the laptop not the power outlet
- That cylinder is called a choke. The purpose of the item is to deflect electrical interferences from the outside sources...like telephones, 2-way radios, ect. It also works as a shield for the brick or power converter that your laptop uses. It also puts out signals that could interfere in other devices.
- Q:Well I guess the more general question is:Are quot;twin power cablescompatible with 12v accessories and motorcycle batteries to make a safe running circuit?
- This is absolutely possible. I would be careful about the weight of cable you use, ensure that it can carry the amp rating of the accessory you want to power from the 12v accessory socket. For example if you're powering a heated vest these can be rated at up to 25 amps. Maplin have a good range of cables at various A ratings. I would also advise you crimp and heatshrink rings onto the cables that you can clamp onto the battery terminals. The Anchor ones are excellent, but Maplin will stock a range of options. You may want to think about wiring an inline fuse, and/or a switch to prevent overheating, and to protect your battery. Hope this helps.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Al / Cu Conductor , Control cable/Aerial, Mining cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches