0.6/1KV Aluminum XLPE Power Cable


0.6/1KV Aluminum XLPE Power Cable with a good price

Standard

The product according to GB/T12706 " rated voltage 35KV and below copper, aluminum plastic insulated power cables " standards, while also based on user needs by the International Electrotechnical Commission standard IEC, British Standards , the German standards and U.S. standards.

Scope

This product is suitable for frequency 0.6/1KV and below rated voltage distribution networks or industrial installations in fixed installations.

Feature

Rated power frequency voltage U0 / U is 0.6/1KV.

Allow cable conductor maximum temperature is 90 ℃.

Short (the longest duration of no more than 5s) conductor temperature does not exceed 250 ℃.

The ambient temperature should not be less than 0 ℃.

Cable bend radius of not less than 15 times the cable diameter.

Model


TypeDesignationNo. of coresNominal cross section of conductor
YJLVAluminium conductor/XLPE insulation/PVC outer sheath Power Cable1, 2, 3, 4, 3+1,5, 4+1, 3+21.5~800mm2
YJLYAluminium conductor/XLPE insulation/PE outer sheath Power Cable1, 2, 3, 4, 3+1,5, 4+1, 3+21.5~800mm2
ZA-YJLV ZB-YJLV ZC-YJLVAluminium conductor/XLPE insulation flame-retardant Power Cable1, 2, 3, 4, 3+1,5, 4+1, 3+21.5~630mm2
WDZA-YJLY WDZB-YJLY WDZC-YJLYAluminium conductor/XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable1, 2, 3, 4, 3+1,5, 4+1, 3+21.5~800mm2


Introduction of our company


Our company is a professional China Wire and Cable Manufacturers, mainly supply Aerial bundled cable,House Electric Wire, Insulated Overhead Cable,Aluminium Conductor Steel Reinforced, PVC Control Cables,XLPE Power Cables,BV Electric Wires,Nylon Sheathed Cable,Buried Cable,High Voltage Cable,House Electric Wire,Single Core Flexible Copper Cable,Civil Wire And Cable etc. series of wire and cable products, sincerely welcome everyone to visit.


Q: can we install power 480 VAC and control 120 VAC cables,,, each one in different conduit but in parallel and adjacent ?also for two control cables ,,,, can they installed in one conduit ?
It is a standard practiceto run power and control cables in different conduit but the basic criteria is voltage gradings.All cables upto 500volts can be laid in one conduit whether power or conrol.In case of high voltage cables, because of elecromagnetic inducion effect, different conduit is adopted.
Q: What kind of cable does the power cable 3 (1 * 240) +2 (1 * 120) Is it a separate cable?
In fact, this is obviously three single-core 240 cable plus two single-core 120 cable, which is a total of five cables, I hope you do not understand, then do not mess up, so as not to
Q: Power cable, the wire yellow line green line red line black line blue line why the line?
VV06 / 13X185 + 1X95 copper core PVC insulated PVC sheathed power cable Reference Price: low voltage power cable VV06 / 13X185 + 1X95 latest price 【2015-06-03】 Specifications: 3X185 +1X95 Conductor technology: B-3; red this price: 34195 yuan / m; monitoring price: 28502 yuan / m VV2206 / 13X185 + 1X95 copper core PVC insulated steel tape armored PVC sheathed power cable reference Price: low voltage power cable VV2206 / 13X185 + 1X95 latest price 【2015-06-03】 Specifications : 3X185 + 1X95; conductor technology: B-3; red price: 35041 yuan / m; monitoring price: 37734 yuan / m YJV06 / 13X185 + 1X95 copper core XLPE insulated PVC sheathed power cable Reference Price: low voltage power cable YJV06 / 13X185 + 1X95 latest price 【2015-06-03】 Specifications: 3X185 + 1X95 conductor technology: B-3; red price: 34084 yuan / m; monitoring price: 28477 yuan / m YJV2206 / 13X185 + 1X95 copper core XLPE insulated steel tape armored PVC sheathed power cable Reference Price: low voltage power cable YJV2206 / 13X185 + 1X95 latest price [2015-06-03] Specifications: 3X185 +1X95; conductor technology: B-3; red price: 34900 yuan / m; monitoring price: 37573 yuan / m Note: Conductor technology: B-3 stranded shaped conductor (such as fan); monitoring price is the latest reference price Quote data from: "cable (dianlancn)" network - the network red price
Q: HiIs it advisable to run 110VAC cable from the sub stationa and 110VAC cable from generator (clean) in the same conduit ; one of them for lighting and the other for CCTV; the concern is if the one for lighting is not clean (not consisting of a pure sine wave or carrying interference) would that effect the power line of the CCTV and has an effect on the picture? even though both are 110VAC.the installation is over seas where the power from the station is not consistence.
If both are simple power lines, then you won't have a problem. The only time you need to be cautious is when you are running a high-voltage power cable and a signal cable alongside each other e.g. a 110VAC cable alongside a 4-20ma signal line from a transmitter. The reason for the potential interference is that the power cable emits an electro-magnetic field which can potentially cause induction in the cable alongside it and effect the signal with an induced EMF. The likelihood of this depends on the cable type, screening and correct earthing measures. It's a good bet to never run a power and signal cable alongside each other, and if you have no other choice, seperate them by means of a makeshift Faraday Cage. If both are doing nothing other than supplying power to the system though, then any induced EMF will be so minute, it will not likely affect the system in any way.
Q: The voltage level of the cable is how much the number of high and low voltage cables
Color line, HDMI cable, S-terminal line of the three transmission video signal (HDMI can also transmit audio signal); coaxial line is the transmission of audio signals
Q: power cables of 630 mm buried (cable trench) what could be the reason for fire?
a power surge can definitely cause a cable fire. but i believe insulation failure tops that, in buried cables in particular. and insulation failure is prompted more often with cables that come in direct contact with the earth, rather than those that may be run through piping, deterioting the insulation even faster. of course if the cable is damaged by digging, that could start a fire as well.
Q: I have a power cable for my computer that got slightly chewed and i was wondering does that effect the power.im just wanting to know if it will have less power or will it work the same and as far as i know none of the wires where hurt just the rubber around them.
replace your cable as its now a fire and shock risk
Q: I'm going to be running 1/0 gauge power wire in my car. My amp only accepts 4 gauge. Is it better to run 1 the whole way through and use power cable adaptors to fit the amp or run the 1 gauge into a distribution block that sizes the output wire down to a 4?
Basic rule of electronics: Eliminate as many connections as possible. If you are using just the one amp, it is better to use one connector that reduces the size of the wire (or just trim it down to fit) than adding two more connections (with a distribution block).
Q: lets say for an optical drive, the power cable has four pins. im guessing that there is power (12v?) and ground but what about the other two?im trying to plug a pair or old neon sticks into my car for accent lighting and i need to know where to put these wires at, if they are all neccessary.
The four pin connector that is used to power PC drives supplies two different voltages: +12 volts for the motor +5 volts for the electonics The other two pins are ground pins. ________ / .............. |..1..2..3..4..| |.................| Pin Function 1 +5 V 2 Ground 3 Ground 4 +12 V
Q: I'm trying to install my radeon x800 xl graphics card into my dell inspiron 531 desktop. After inserting the card in the pci-e slot, and connecting the monitor cord to the card, I thought everything would work fine. I booted the computer and I got the error quot;You have not connected the power cable to your video cardquot;What do I need to do? This is an older video card, and I may have lost this supposed power cable. I'm lost with this and my computer won't even boot now. Any help is much appreciated. I'm willing to buy this power cord if i need to.
there are lots of connectors coming off PC power supplies that provide 12V and can likely drive your graphics card. So if you want to get really brave and do some soldering you can probably make it work. For example, if you're not using your floppy, you can chop off that connector and wire it to your card.