• Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station System 1
  • Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station System 2
  • Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station System 3
Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station

Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

  Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station

1.Structure of Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station

QZB Axial Flow pump is the new upgrated product of the tradition ones. they are used in applications that require very high flow rates and very low amounts of pressure (head). They are useful as circulating water pumps in power plants. They’re also commonly used in the chemical industry for circulating large amounts of fluids in evaporators. And they are useful in flood dewatering applications where large quantities of water need to be moved a short distance, such as over a levee or dyke. These applications are not nearly as common as applications for radial flow pumps, so there are not nearly as many axial flow pumps as there are radial flow pumps. QZB axial flow pump is combined of pump and submersible motor parts. Pump mainly contains sectional bell, impeller, impeller casing, and diffusor. And the submersible motor is the dry closed asynchronous one, which makes sure that the motor can work smoothly in water.

 

2.Main Features of Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station

• Compact structure, good appearance, low construction

•Operation stably,high efficiency

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

3.Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm Station Images

 

Vertical Submersible Axial Flow / Mixed Flow Water Pump

Vertical Submersible Axial Flow / Mixed Flow Water Pump

4.Vertical Submersible Axial Flow / Mixed Flow Water Pump for Storm StationSpecification

Material

Cast iron, stainless steel

Pump diameter

350-1600mm

Capacity

500-45000m3/hr

Discharge

1.5-20m

Power

22-800KW

Max water temperature

50ºC

Medium volume ratio

< 2%

Medium max density of

< 1.2×103kg/m3

Medium

lightly contaminated water

5.FAQ

①What is the applications?

QZB axial flow pump are used in flood dewatering application, water supplying and dewatering in urban area, storm-water drainage, agriculture and industry water supplying, water transfering etc.

②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. It related to the state and detailed requirement of customers.

Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q:What should be used to pay attention to the use of mechanical pumps?
Overall: large pump should first do a good job of the foundation, to find a good whole, fixed, and motor, pump should be added good oil, the first test of the motor, and then conjoined test
Q:Advantages and disadvantages of centrifugal pumps?
The uniform liquid no pulse phenomenon.(2) shortcomingsBefore running, the pump must be filled with liquid.For the supply of small flow, large pressure head inappropriate, inefficient and limited.Encountered imperfect design or operation is not at the time, such as milk, it is easy to produce foam, affecting the next process production.The installation is wrong. There will be "Qi tie" phenomenon.The efficiency is also lower than the reciprocating pump.The sources of knowledge are absolutely reliable!!!!
Q:What is the pump delivery? What's the difference between years and years?
Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
Q:What is an industrial water pump?
Classification by usagePump, circulating pump, fire pump, pressure test pump, sewage pump, metering pump, sanitary pump, dosing pump, pump, pump, gelatinization defoaming pump, flow pump, oil pump, water pump, drainage pump, drainage pump, dredging pump, sprinkler pump, booster pump, high pressure pump, heat pump high temperature, low temperature, pump pump, condensate pump, heat pump, cooling pump, heating pump, deep well pump, analgesic pump, pump, pump, chemotherapy, blood pump material pumping pump, pump, pump, sulfur removal, shearing grinding pump fuel pump, pump, pump, quillback bath source heat pump, filter pump oxygen pump, pump, shampoo, injection pump, air pump, gas pump, pump, pump, art odorization pump chopped
Q:The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
Q:What is a solution pump?
2.1 advantages of canned pumps(1) fully enclosed. There is no dynamic seal in the structure. Only the static seal in the outer shell of the pump can be made without leakage. It is especially suitable for transporting flammable, explosive, precious liquids and toxic, corrosive and radioactive liquids(2) high safety. The rotor and stator each have a shielding sleeve, so that the rotor and stator of the motor are not in contact with the material, even if the shield is broken, it will not produce the risk of leakage and leakage(3) compact structure and small footprint, the pump and motor is a whole, disassembly and assembly do not need to find the center. The base and foundation requirements are low, and the daily maintenance workload is low, and the maintenance cost is low
Q:What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
Q:What are the important parameters of the pump?
Mass flow is expressed in Qm units: t/h, kg/s, etc.The relation between mass flow and volume flow is:Qm= P QIn the p - type liquid density (kg/m3, t/m3), room temperature water P =1000kg/m3.Lift H
Q:Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches