• Horizontal Single Stage Double Suction Centrifugal Water Pump System 1
  • Horizontal Single Stage Double Suction Centrifugal Water Pump System 2
  • Horizontal Single Stage Double Suction Centrifugal Water Pump System 3
Horizontal Single Stage Double Suction Centrifugal Water Pump

Horizontal Single Stage Double Suction Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                Horizontal Single Stage Double Suction Centrifugal Water Pump

1.Structure of  Horizontal Single Stage Double Suction Centrifugal Water Pump Description

 

Horizontal Single Stage Double Suction Centrifugal Water Pump is a single-stage centrifugal pump, horizontal in the open, for the transport of water and physical and chemical properties similar to water in liquid, the liquid temperature should not exceed 80 °C, suitable for factories, mines, power plants, city drainage, drainage irrigation and water conservancy

 

2.Main Features of the Horizontal Single Stage Double Suction Centrifugal Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Horizontal Single Stage Double Suction Centrifugal Water Pump images

Horizontal Single Stage Double Suction Centrifugal Water Pump

4. Horizontal Single Stage Double Suction Centrifugal Water Pump Specification

 

Item

Agricultural irrigation water pump

Electric irrigation water pump

SH series agricultural irrigation water pump

Model

SH

Material

Cast iron and customized

Color

Blue and adjustable

Mode

Horizontal

Impeller

Double suction impeller

Drive

Belt or coupling

Seal

Soft packing seal or mechanical seal

Speed

2950r/m, 1470r/min, 970r/min

Theory

Centrifugal pump

Structure

Single stage pup

Usage

Pure water or raw water

Power

Electric

Standard or Nonstandard

Standard

Application

Plant, mine, power station, urban water supply, irrigation

Outlet diameter

100-900mm

Capacity

111-12500m³/h

Head

8.6-140m

Power

22-1250kw

Warranty

1year

Certificate

ISO9001

OEM

Acceptable

Feature

High flow rate, high efficiency, easy maintenance

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: How to adjust the flow of piston pump?
For the swashplate valve controlled by the solenoid valve, the swashplate is in an angle with the cylinder body, so the plunger is reciprocating in the pump cylinder when the cylinder rotates. It goes from 0 degrees to 180 degrees, that is, to the upper plunger position, the plunger cylinder volume gradually increased
Q: What is a solution pump?
Principle and structure features of canned motor pumpThe ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and drive the rotor. This structure eliminated the traditional centrifugal pump with a rotary shaft sealing device, it can do no leakage.The pump and motor pump together, motor rotor and pump impeller fixed on the same shaft, use of shielding the rotor and the stator of the motor rotor separated in the medium, its power is transferred to the rotor through the stator magnetic field.
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q: Does vacuum pump oil belong to dangerous goods?
Absolutely not. We often send oil by express or by freight. There are no problems at all. Don't be afraid, don't burn, explode
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q: What is a positive displacement pump? He Weizheng displacement?
Includes a pump housing (10), a pump chamber (24), the pump chamber has an entrance channel (21) and an outlet check valve (17) export control channel (28), a displacement member (13), the definition of the pump cavity in a direction of movement in (24) and in a stroke section in the pump cavity (S) in reciprocating motion
Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.
Q: Filter backwash pump for what use, what is the principle of work ah?
But the reverse cleaning can not completely regenerate the filter medium, or there will be some impurities remain, when the regeneration of residual impurities (pressure drop) to set the value, you need to replace the filter (filter media).
Q: What do you mean by the self coupling device on the pump?
Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords